Abstract: This paper investigates the performance comparison of SVC (Static VAR Compensator) and DSTATCOM (Distribution Static Synchronous Compensator) to improve voltage stability in Radial Distribution System (RDS) which are efficient FACTS (Flexible AC Transmission System) devices that are capable of controlling the active and reactive power flows in a power system line by appropriately controlling parameters using ANFIS. Simulations are carried out in MATLAB/Simulink environment for the IEEE-4 bus system to test the ability of increasing load. It is found that these controllers significantly increase the margin of load in the power systems.
Abstract: There exist significant losses on transmission lines due to distance, as power generating stations could be located far from some isolated settlements. Standalone wind farms could be a good choice of alternative power generation for such settlements that are far from the grid due to factors of long distance or socio-economic problems. However, uncompensated wind farms consume reactive power since wind turbines are induction generators. Therefore, capacitor banks are used to compensate reactive power, which in turn improves the voltage profile of the network. Although capacitor banks help improving voltage profile, they also undergo switching actions due to its compensating response to the variation of various types of load at the consumer’s end. These switching activities could cause transient overvoltage on the network, jeopardizing the end-life of other equipment on the system. In this paper, the overvoltage caused by these switching activities is investigated using the IEEE bus 14-network to represent a standalone wind farm, and the simulation is done using ATP/EMTP software. Scenarios involving the use of pre-insertion resistor and pre-insertion inductor, as well as controlled switching was also carried out in order to decide the best mitigation option to reduce the overvoltage.
Abstract: This paper presents the modeling and the control of a grid-connected photovoltaic system (PVS). Firstly, the MPPT control of the PVS and its associated DC/DC converter has been analyzed in order to extract the maximum of available power. Secondly, the control system of the grid side converter (GSC) which is a three-phase voltage source inverter (VSI) has been presented. A special attention has been paid to the control algorithms of the GSC converter during grid voltages imbalances. Especially, three different control objectives are to achieve; the mitigation of the grid imbalance adverse effects, at the point of common coupling (PCC), on the injected currents, the elimination of double frequency oscillations in active power flow, and the elimination of double frequency oscillations in reactive power flow. Simulation results of two control strategies have been performed via MATLAB software in order to demonstrate the particularities of each control strategy according to power quality standards.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: Photovoltaic (PV) power generation systems, mainly
small scale, are rapidly being deployed in Jordan. The impact of these
systems on the grid has not been studied or analyzed. These systems
can cause many technical problems such as reverse power flows and
voltage rises in distribution feeders, and real and reactive power
transients that affect the operation of the transmission system. To
fully understand and address these problems, extensive research,
simulation, and case studies are required. To this end, this paper
studies the cloud shadow effect on the power generation of a ground
mounted PV system installed at the test field of the Renewable
Energy Center at the Applied Science University.
Abstract: The use of Flexible AC Transmission System
(FACTS) devices in a power system can potentially overcome
limitations of the present mechanically controlled transmission
system. Also, the advance of technology makes possible to include
new energy storage devices in the electrical power system. The
integration of Superconducting Magnetic Energy Storage (SMES)
into Static Synchronous Compensator (STATCOM) can lead to
increase their flexibility in improvement of power system dynamic
behaviour by exchanging both active and reactive powers with power
grids. This paper describes structure and behaviour of SMES,
specifications and performance principles of the STATCOM/SMES
compensator. Moreover, the benefits and effectiveness of integrated
SMES with STATCOM in power systems is presented. Also, the
performance of the STATCOM/SMES compensator is evaluated
using an IEEE 3-bus system through the dynamic simulation by
PSCAD/EMTDC software.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: In a practical power system, the power plants are not
located at the same distance from the center of loads and their fuel
costs are different. Also, under normal operating conditions, the
generation capacity is more than the total load demand and losses.
Thus, there are many options for scheduling generation. In an
interconnected power system, the objective is to find the real and
reactive power scheduling of each power plant in such a way as to
minimize the operating cost. This means that the generator’s real and
reactive powers are allowed to vary within certain limits so as to meet
a particular load demand with minimum fuel cost. This is called
optimal power flow problem. In this paper, Economic Load Dispatch
(ELD) of real power generation is considered. Economic Load
Dispatch (ELD) is the scheduling of generators to minimize total
operating cost of generator units subjected to equality constraint of
power balance within the minimum and maximum operating limits of
the generating units. In this paper, genetic algorithms are considered.
ELD solutions are found by solving the conventional load flow
equations while at the same time minimizing the fuel costs.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: One of the key aspects of power quality improvement
in power system is the mitigation of voltage sags/swells and flicker.
Custom power devices have been known as the best tools for voltage
disturbances mitigation as well as reactive power compensation.
Dynamic Voltage Restorer (DVR) which is the most efficient and
effective modern custom power device can provide the most
commercial solution to solve several problems of power quality in
distribution networks. This paper deals with analysis and simulation
technique of DVR based on instantaneous power theory which is a
quick control to detect signals. The main purpose of this work is to
remove three important disturbances including voltage sags/swells
and flicker. Simulation of the proposed method was carried out on
two sample systems by using Matlab software environment and the
results of simulation show that the proposed method is able to
provide desirable power quality in the presence of wide range of
disturbances.
Abstract: Flexible AC Transmission Systems (FACTS) is
granting a new group of advanced power electronic devices emerging
for enhancement of the power system performance. Unified Power
Flow Controller (UPFC) is a recent version of FACTS devices for
power system applications. The back-up energy supply system
incorporated with UPFC is providing a complete control of real and
reactive power at the same time and hence is competent to improve
the performance of an electrical power system. In this article, backup
energy supply unit such as superconducting magnetic energy storage
(SMES) is integrated with UPFC. In addition, comparative
exploration of UPFC–battery, UPFC–UC and UPFC–SMES
performance is evaluated through the vibrant simulation by using
MATLAB/Simulink software.
Abstract: Power systems are operating under stressed condition
due to continuous increase in demand of load. This can lead to
voltage instability problem when face additional load increase or
contingency. In order to avoid voltage instability suitable size of
reactive power compensation at optimal location in the system is
required which improves the load margin. This work aims at
obtaining optimal size as well as location of compensation in the 39-
bus New England system with the help of Bacteria Foraging and
Genetic algorithms. To reduce the computational time the work
identifies weak candidate buses in the system, and then picks only
two of them to take part in the optimization. The objective function is
based on a recently proposed voltage stability index which takes into
account the weighted average sensitivity index is a simpler and faster
approach than the conventional CPF algorithm. BFOA has been
found to give better results compared to GA.
Abstract: In this paper an isolated wind-diesel hybrid power
system has been considered for reactive power control study having
an induction generator for wind power conversion and synchronous
alternator with automatic voltage regulator (AVR) for diesel unit is
presented. The dynamic voltage stability evaluation is dependent on
small signal analysis considering a Static VAR Compensator (SVC)
and IEEE type -I excitation system. It's shown that the variable
reactive power source like SVC is crucial to meet the varying
demand of reactive power by induction generator and load and to
acquire an excellent voltage regulation of the system with minimum
fluctuations. Integral square error (ISE) criterion can be used to
evaluate the optimum setting of gain parameters. Finally the dynamic
responses of the power systems considered with optimum gain setting
will also be presented.
Abstract: There are a variety of reference current identification
methods, for the shunt active power filter (SAPF), such as the
instantaneous active and reactive power, the instantaneous active and
reactive current and the synchronous detection method are evaluated
and compared under ideal, non sinusoidal and unbalanced voltage
conditions. The SAPF performances, for the investigated
identification methods, are tested for a non linear load. The
simulation results, using Matlab Power System Blockset Toolbox
from a complete structure, are presented and discussed.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.