Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: In the last few years, harmonics have been occurred
with the increasing use of nonlinear loads, and these harmonics have
been an ever increasing problem for the line systems. This situation
importantly affects the quality of power and gives large losses to the
network. An efficient way to solve these problems is providing
harmonic compensation through parallel active power filters. Many
methods can be used in the control systems of the parallel active
power filters which provide the compensation. These methods
efficiently affect the performance of the active power filters. For this
reason, the chosen control method is significant. In this study, Fourier
analysis (FA) control method and synchronous reference frame (SRF)
control method are discussed. These control methods are designed for
both eliminate harmonics and perform reactive power compensation
in MATLAB/Simulink pack program and are tested. The results have
been compared for each two methods.
Abstract: This paper presents a method for obtaining the
desired reference current for Voltage Source Converter (VSC) of the Shunt Active Power Filter (SAPF) using Synchronous Reference Frame Theory. The method relies on the performance of the Proportional-Integral (PI) controller for
obtaining the best control performance of the SAPF. To
improve the performance of the PI controller, the feedback
path to the integral term is introduced to compensate the
winding up phenomenon due to integrator. Using Reference
Frame Transformation, reference signals are transformed from
a - b - c stationery frame to 0 - d - q rotating frame.
Using the PI controller, the reference signals in the 0 - d - q rotating frame are controlled to get the desired reference signals for the Pulse Width Modulation. The synchronizer, the Phase Locked Loop (PLL) with PI filter is used for
synchronization, with much emphasis on minimizing delays. The system performance is examined with Shunt Active Power Filter simulation model.
Abstract: A generalized unified power quality conditioner
(GUPQC) by using three single-phase three-level voltage source
converters (VSCs) connected back-to-back through a common dc
link is proposed in this paper as a new custom power device for a
three-feeder distribution system. One of the converters is connected
in shunt with one feeder for mitigation of current harmonics and
reactive power compensation, while the other two VSCs are
connected in series with the other two feeders to maintain the load
voltage sinusoidal and at constant level. A new control scheme based
on synchronous reference frame is proposed for series converters.
The simulation analysis on compensation performance of GUPQC
based on PSCAD/EMTDC is reported.
Abstract: In this paper the reference current for Voltage Source
Converter (VSC) of the Shunt Active Power Filter (SAPF) is
generated using Synchronous Reference Frame method,
incorporating the PI controller with anti-windup scheme. The
proposed method improves the harmonic filtering by compensating
the winding up phenomenon caused by the integral term of the PI
controller.
Using Reference Frame Transformation, the current is transformed
from om a - b - c stationery frame to rotating 0 - d - q frame. Using
the PI controller, the current in the 0 - d - q frame is controlled to
get the desired reference signal. A controller with integral action
combined with an actuator that becomes saturated can give some
undesirable effects. If the control error is so large that the integrator
saturates the actuator, the feedback path becomes ineffective because
the actuator will remain saturated even if the process output changes.
The integrator being an unstable system may then integrate to a very
large value, the phenomenon known as integrator windup.
Implementing the integrator anti-windup circuit turns off the
integrator action when the actuator saturates, hence improving the
performance of the SAPF and dynamically compensating harmonics
in the power network. In this paper the system performance is
examined with Shunt Active Power Filter simulation model.