Abstract: Acoustic noise becoming ever more obnoxious radiated by voltage source inverter fed induction motor drive in modern and industrial applications. The drive utilized for industrial and modern applications should use “spread spectrum” innovation known as Random pulse width modulation (PWM) algorithms where acoustic noise emanates through the machine should be critically concerned. This paper illustrates three types of random PWM control algorithms with fixed switching frequency namely 1) Random modulating PWM 2) Random carrier PWM and 3) Random modulating-carrier PWM. The spectrum plots of the motor stator current demonstrate the strength and robustness of the proposed PWM algorithms. To affirm the proposed algorithms, experimental tests have been conducted using dSPACE rt1104 control board on a v/f control three phase induction motor drive fed by DC link cascaded multilevel inverter.
Abstract: This article presents the design of optimal automatic generation control (AGC) based on full state feedback control for a multi-area interconnected power system. An extra high voltage AC transmission line in parallel with a high voltage DC link is considered as an area interconnection between the areas. The optimal AGC are designed and implemented in the wake of 1% load perturbation in one of the areas and the system dynamic response plots for various system states are obtained to investigate the system dynamic performance. The pattern of closed-loop eigenvalues are also determined to analyze the system stability. From the investigations carried out in the work, it is revealed that the dynamic performance of the system under consideration has an appreciable improvement when a high voltage DC line is paralleled with an extra high voltage AC line as an interconnection between the areas. The investigation of closed-loop eigenvalues reveals that the system stability is ensured in all case studies carried out with the designed optimal AGC.
Abstract: This paper presents the modeling and the control of a grid-connected photovoltaic system (PVS). Firstly, the MPPT control of the PVS and its associated DC/DC converter has been analyzed in order to extract the maximum of available power. Secondly, the control system of the grid side converter (GSC) which is a three-phase voltage source inverter (VSI) has been presented. A special attention has been paid to the control algorithms of the GSC converter during grid voltages imbalances. Especially, three different control objectives are to achieve; the mitigation of the grid imbalance adverse effects, at the point of common coupling (PCC), on the injected currents, the elimination of double frequency oscillations in active power flow, and the elimination of double frequency oscillations in reactive power flow. Simulation results of two control strategies have been performed via MATLAB software in order to demonstrate the particularities of each control strategy according to power quality standards.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: Back-to-back static synchronous compensator (BtBSTATCOM) consists of two back-to-back voltage-source converters (VSC) with a common DC link in a substation. This configuration extends the capabilities of conventional STATCOM that bidirectional active power transfer from one bus to another is possible. In this paper, VSCs are designed in quasi multi-pulse form in which GTOs are triggered only once per cycle in PSCAD/EMTDC. The design details of VSCs as well as gate switching circuits and controllers are fully represented. Regulation modes of BtBSTATCOM are verified and tested on a multi-machine power system through different simulation cases. The results presented in the form of typical time responses show that practical PI controllers are almost robust and stable in case of start-up, set-point change, and line faults.
Abstract: This paper proposes a feed-forward control in
resonant dc link inverter. The feed-forward control configuration is
based on synchronous sigma-delta modulation. The simulation
results showing the proposed technique can reject non-ideal dc bus
improving the total harmonic distortion.
Abstract: In this paper, a direct torque control - space vector
modulation (DTC-SVM) scheme is presented for a six-phase speed
and voltage sensorless induction motor (IM) drive. The decoupled
torque and stator flux control is achieved based on IM stator flux field orientation. The rotor speed is detected by on-line estimating of
the rotor angular slip speed and stator vector flux speed. In addition, a simple method is introduced to estimate the stator resistance.
Moreover in this control scheme the voltage sensors are eliminated
and actual motor phase voltages are approximated by using PWM
inverter switching times and the dc link voltage. Finally, some simulation and experimental results are presented to verify the
effectiveness and capability of the proposed control scheme.
Abstract: This paper proposes a resonant dc link in PWM ac
chopper. This can solve the spike problems and also reduce the
switching loss. The configuration and PWM pattern of the proposed
technique are presented. The simulation results are used to confirm
the theory.
Abstract: Nowadays there are several grid connected converter
in the grid system. These grid connected converters are generally the
converters of renewable energy sources, industrial four quadrant
drives and other converters with DC link. These converters are
connected to the grid through a three phase bridge. The standards
prescribe the maximal harmonic emission which could be easily
limited with high switching frequency. The increased switching
losses can be reduced to the half with the utilization of the wellknown
Flat-top modulation. The suggested control method is the
expansion of the Flat-top modulation with which the losses could be
also reduced to the half compared to the Flat-top modulation.
Comparing to traditional control these requirements can be
simultaneously satisfied much better with the DLF (DC Link
Floating) method.
Abstract: In a wind power generator using doubly fed induction
generator (DFIG), the three-phase pulse width modulation (PWM)
voltage source converter (VSC) is used as grid side converter (GSC)
and rotor side converter (RSC). The standard linear control laws
proposed for GSC provides not only instablity against comparatively
large-signal disturbances, but also the problem of stability due to
uncertainty of load and variations in parameters. In this paper, a
nonlinear controller is designed for grid side converter (GSC) of a
DFIG for wind power application. The nonlinear controller is
designed based on the input-output feedback linearization control
method. The resulting closed-loop system ensures a sufficient
stability region, make robust to variations in circuit parameters and
also exhibits good transient response. Computer simulations and
experimental results are presented to confirm the effectiveness of the
proposed control strategy.
Abstract: Active Power Filters (APFs) are today the most
widely used systems to eliminate harmonics compensate power
factor and correct unbalanced problems in industrial power plants.
We propose to improve the performances of conventional APFs by
using artificial neural networks (ANNs) for harmonics estimation.
This new method combines both the strategies for extracting the
three-phase reference currents for active power filters and DC link
voltage control method. The ANNs learning capabilities to
adaptively choose the power system parameters for both to compute
the reference currents and to recharge the capacitor value requested
by VDC voltage in order to ensure suitable transit of powers to
supply the inverter. To investigate the performance of this
identification method, the study has been accomplished using
simulation with the MATLAB Simulink Power System Toolbox. The
simulation study results of the new (SAPF) identification technique
compared to other similar methods are found quite satisfactory by
assuring good filtering characteristics and high system stability.
Abstract: In recent years the large scale use of the power electronic equipment has led to an increase of harmonics in the power system. The harmonics results into a poor power quality and have great adverse economical impact on the utilities and customers. Current harmonics are one of the most common power quality problems and are usually resolved by using shunt active filter (SHAF). The main objective of this work is to develop PI and Fuzzy logic controllers (FLC) to analyze the performance of Shunt Active Filter for mitigating current harmonics under balanced and unbalanced sinusoidal source voltage conditions for normal load and increased load. When the supply voltages are ideal (balanced), both PI and FLC are converging to the same compensation characteristics. However, the supply voltages are non-ideal (unbalanced), FLC offers outstanding results. Simulation results validate the superiority of FLC with triangular membership function over the PI controller.
Abstract: This paper proposes a feed-forward control in a halfbridge
resonant dc link inverter. The configuration of feed-forward
control is based on synchronous sigma-delta modulation and the halfbridge
resonant dc link inverter consists of two inductors, one
capacitor and two power switches. The simulation results show the
proposed technique can reject non-ideal dc bus improving the total
harmonic distortion.