Abstract: This article presents the design of optimal automatic generation control (AGC) based on full state feedback control for a multi-area interconnected power system. An extra high voltage AC transmission line in parallel with a high voltage DC link is considered as an area interconnection between the areas. The optimal AGC are designed and implemented in the wake of 1% load perturbation in one of the areas and the system dynamic response plots for various system states are obtained to investigate the system dynamic performance. The pattern of closed-loop eigenvalues are also determined to analyze the system stability. From the investigations carried out in the work, it is revealed that the dynamic performance of the system under consideration has an appreciable improvement when a high voltage DC line is paralleled with an extra high voltage AC line as an interconnection between the areas. The investigation of closed-loop eigenvalues reveals that the system stability is ensured in all case studies carried out with the designed optimal AGC.
Abstract: In an interconnected power system, any sudden small
load perturbation in any of the interconnected areas causes the
deviation of the area frequencies, the tie line power and voltage
deviation at the generator terminals. This paper deals with the study
of performance of intelligent Fuzzy Logic controllers coupled with
Conventional Controllers (PI and PID) for Load Frequency Control.
For analysis, an isolated single area and interconnected two area
thermal power systems with and without generation rate constraints
(GRC) have been considered. The studies have been performed with
conventional PI and PID controllers and their performance has been
compared with intelligent fuzzy controllers. It can be demonstrated
that these controllers can successfully bring back the excursions in
area frequencies and tie line powers within acceptable limits in
smaller time periods and with lesser transients as compared to the
performance of conventional controllers under same load disturbance
conditions. The simulations in MATLAB have been used for
comparative studies.
Abstract: This paper deals with the application of artificial
neural network (ANN) and fuzzy based Adaptive Neuro Fuzzy
Inference System(ANFIS) approach to Load Frequency Control
(LFC) of multi unequal area hydro-thermal interconnected power
system. The proposed ANFIS controller combines the advantages of
fuzzy controller as well as quick response and adaptability nature of
ANN. Area-1 and area-2 consists of thermal reheat power plant
whereas area-3 and area-4 consists of hydro power plant with electric
governor. Performance evaluation is carried out by using intelligent
controller like ANFIS, ANN and Fuzzy controllers and conventional
PI and PID control approaches. To enhance the performance of
intelligent and conventional controller sliding surface is included.
The performances of the controllers are simulated using
MATLAB/SIMULINK package. A comparison of ANFIS, ANN,
Fuzzy, PI and PID based approaches shows the superiority of
proposed ANFIS over ANN & fuzzy, PI and PID controller for 1%
step load variation.
Abstract: The optimal design of PI controller for Automatic Generation Control in two area is presented in this paper. The concept of Dual mode control is applied in the PI controller, such that the proportional mode is made active when the rate of change of the error is sufficiently larger than a specified limit otherwise switched to the integral mode. A digital simulation is used in conjunction with the Hooke-Jeeve’s optimization technique to determine the optimum parameters (individual gain of proportional and integral controller) of the PI controller. Integrated Square of the Error (ISE), Integrated Time multiplied by Absolute Error(ITAE) , and Integrated Absolute Error(IAE) performance indices are considered to measure the appropriateness of the designed controller. The proposed controller are tested for a two area single nonreheat thermal system considering the practical aspect of the problem such as Deadband and Generation Rate Constraint(GRC). Simulation results show that dual mode with optimized values of the gains improved the control performance than the commonly used Variable Structure .
Abstract: This paper deals with the tuning of parameters for Automatic Generation Control (AGC). A two area interconnected hydrothermal system with PI controller is considered. Genetic Algorithm (GA) and Particle Swarm optimization (PSO) algorithms have been applied to optimize the controller parameters. Two objective functions namely Integral Square Error (ISE) and Integral of Time-multiplied Absolute value of the Error (ITAE) are considered for optimization. The effectiveness of an objective function is considered based on the variation in tie line power and change in frequency in both the areas. MATLAB/SIMULINK was used as a simulation tool. Simulation results reveal that ITAE is a better objective function than ISE. Performances of optimization algorithms are also compared and it was found that genetic algorithm gives better results than particle swarm optimization algorithm for the problems of AGC.