Abstract: This paper describes the effects of photovoltaic voltage changes on Multi-level inverter (MLI) due to solar irradiation variations, and methods to overcome these changes. The irradiation variation affects the generated voltage, which in turn varies the switching angles required to turn-on the inverter power switches in order to obtain minimum harmonic content in the output voltage profile. Genetic Algorithm (GA) is used to solve harmonics elimination equations of eleven level inverters with equal and non-equal dc sources. After that artificial neural network (ANN) algorithm is proposed to generate appropriate set of switching angles for MLI at any level of input dc sources voltage causing minimization of the total harmonic distortion (THD) to an acceptable limit. MATLAB/Simulink platform is used as a simulation tool and Fast Fourier Transform (FFT) analyses are carried out for output voltage profile to verify the reliability and accuracy of the applied technique for controlling the MLI harmonic distortion. According to the simulation results, the obtained THD for equal dc source is 9.38%, while for variable or unequal dc sources it varies between 10.26% and 12.93% as the input dc voltage varies between 4.47V nd 11.43V respectively. The proposed ANN algorithm provides satisfied simulation results that match with results obtained by alternative algorithms.
Abstract: Grid connected solar PV inverters need to be compliant to standard regulations regarding unwanted harmonic generation. This paper gives an introduction to harmonics, solar PV inverter voltage regulation and balancing through compensation and investigates the behaviour of harmonic generation at different power levels. Practical measurements of harmonics and power levels with a power quality data logger were made, on a test network at a university in Germany. The test setup and test results are discussed. The major finding was that between the morning and afternoon load peak windows when the PV inverters operate under low solar insolation and low power levels, more unwanted harmonics are generated. This has a huge impact on the power quality of the grid as well as capital and maintenance costs. The design of a single-tuned harmonic filter towards harmonic mitigation is presented.
Abstract: Multi-Level Inverter technology has been developed in the area of high-power medium-voltage energy scheme, because of their advantages such as devices of lower rating can be used thereby enabling the schemes to be used for high voltage applications. Reduced Total Harmonic Distortion (THD).Since the dv/dt is low; the Electromagnetic Interference from the scheme is low. To avoid the switching losses Lower switching frequencies can be used. In this paper present a survey of various topologies, control strategy and modulation techniques used by these inverters. Here the regenerative and superior topologies are also discussed.
Abstract: This paper proposes a feed-forward control in
resonant dc link inverter. The feed-forward control configuration is
based on synchronous sigma-delta modulation. The simulation
results showing the proposed technique can reject non-ideal dc bus
improving the total harmonic distortion.
Abstract: Active Power Filters (APFs) are today the most
widely used systems to eliminate harmonics compensate power
factor and correct unbalanced problems in industrial power plants.
We propose to improve the performances of conventional APFs by
using artificial neural networks (ANNs) for harmonics estimation.
This new method combines both the strategies for extracting the
three-phase reference currents for active power filters and DC link
voltage control method. The ANNs learning capabilities to
adaptively choose the power system parameters for both to compute
the reference currents and to recharge the capacitor value requested
by VDC voltage in order to ensure suitable transit of powers to
supply the inverter. To investigate the performance of this
identification method, the study has been accomplished using
simulation with the MATLAB Simulink Power System Toolbox. The
simulation study results of the new (SAPF) identification technique
compared to other similar methods are found quite satisfactory by
assuring good filtering characteristics and high system stability.