Abstract: This paper presents a speed estimation scheme based
on second-order sliding-mode Super Twisting Algorithm (STA) and
Model Reference Adaptive System (MRAS) estimation theory for
Sensorless control of multiphase induction machine. A stator current
observer is designed based on the STA, which is utilized to take the
place of the reference voltage model of the standard MRAS
algorithm. The observer is insensitive to the variation of rotor
resistance and magnetizing inductance when the states arrive at the
sliding mode. Derivatives of rotor flux are obtained and designed as
the state of MRAS, thus eliminating the integration. Compared with
the first-order sliding-mode speed estimator, the proposed scheme
makes full use of the auxiliary sliding-mode surface, thus alleviating
the chattering behavior without increasing the complexity. Simulation
results show the robustness and effectiveness of the proposed
scheme.
Abstract: Temperature effect on the performance of a photovoltaic module is one of the main concerns that face this renewable energy, especially in hot arid region, e.g. United Arab Emirates. Overheating of the PV modules reduces the open circuit voltage and the efficiency of the modules dramatically. In this work, water-cooling is developed to enhance the performance of PV modules. Different scenarios are tested under UAE weather conditions: front, back and double cooling. A spraying system is used for the front cooling whether a direct contact water system is used for the back cooling. The experimental results are compared to non-cooling module and the performance of the PV module is determined for different situations. The experimental results show that the front cooling is more effective than the back cooling and may decrease the temperature of the PV module significantly.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: Photovoltaic (PV) power generation systems, mainly
small scale, are rapidly being deployed in Jordan. The impact of these
systems on the grid has not been studied or analyzed. These systems
can cause many technical problems such as reverse power flows and
voltage rises in distribution feeders, and real and reactive power
transients that affect the operation of the transmission system. To
fully understand and address these problems, extensive research,
simulation, and case studies are required. To this end, this paper
studies the cloud shadow effect on the power generation of a ground
mounted PV system installed at the test field of the Renewable
Energy Center at the Applied Science University.
Abstract: In this study, electric field distribution analyses for
three pylon models are carried out by a Finite Element Method
(FEM) based software. Analyses are performed in both stationary and
time domains to observe instantaneous values along with the
effective ones. Considering the results of the study, different line
geometries is considerably affecting the magnitude and distribution
of electric field although the line voltages are the same. Furthermore,
it is observed that maximum values of instantaneous electric field
obtained in time domain analysis are quite higher than the effective
ones in stationary mode. In consequence, electric field distribution
analyses should be individually made for each different line model
and the limit exposure values or distances to residential buildings
should be defined according to the results obtained.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: In insulation and cooling of power transformers
various liquids are used. Mineral oils have wide availability and low
cost. However, they have a poor biodegradability potential and lower
fire point in comparison with other insulating liquids. Use of a liquid
having high biodegradability is important due to environmental
consideration. This paper investigates edible corn oil as an alternative
to mineral oil. Various properties of mineral and corn oil like
breakdown voltage, dissipation factor, relative dielectric constant,
power loss and resistivity were measured according to different
standards.
Abstract: Efficient use of energy, the increase in demand of
energy and also with the reduction of natural energy sources, has
improved its importance in recent years. Most of the losses in the
system from electricity produced until the point of consumption is
mostly composed by the energy distribution system. In this study,
analysis of the resulting loss in power distribution transformer and
distribution power cable is realized which are most of the losses in
the distribution system. Transformer losses in the real distribution
system are analyzed by CYME Power Engineering Software
program. These losses are disclosed for different voltage levels and
different loading conditions.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: As the Silicon oxide scaled down in MOSFET
technology to few nanometers, gate Direct Tunneling (DT) in
Floating gate (FGMOSFET) devices has become a major concern for
analog designers. FGMOSFET has been used in many low-voltage
and low-power applications, however, there is no accurate model that
account for DT gate leakage in nano-scale. This paper studied and
analyzed different simulation models for FGMOSFET using TSMC
90-nm technology. The simulation results for FGMOSFET cascade
current mirror shows the impact of DT on circuit performance in
terms of current and voltage without the need for fabrication. This
works shows the significance of using an accurate model for
FGMOSFET in nan-scale technologies.
Abstract: This paper introduces a boost converter with a new
active snubber cell. In this circuit, all of the semiconductor
components in the converter softly turns on and turns off with the
help of the active snubber cell. Compared to the other converters, the
proposed converter has advantages of size, number of components
and cost. The main feature of proposed converter is that the extra
voltage stresses do not occur on the main switches and main diodes.
Also, the current stress on the main switch is acceptable level.
Moreover, the proposed converter can operates under light load
conditions and wide input line voltage. In this study, the operating
principle of the proposed converter is presented and its operation is
verified with the Proteus simulation software for a 1 kW and 100 kHz
model.
Abstract: Polyaniline is an indispensible component in lightemitting
devices (LEDs), televisions, cellular telephones, automotive,
corrosion-resistant coatings, actuators etc. The electrical conductivity
properties was found be increased by introduction of metal nano
particles. In the present study, an attempt has been made to utilize
platinum nano particles to achieve the improved electrical properties.
Polyaniline and Pt-polyaniline composite are synthesized by
electrochemical routes. X-ray diffractometer confirms the amorphous
nature of polyaniline. The Bragg’s diffraction peaks correspond to
platinum nanoparticles in Pt-polyaniline composite and
thermogravimetric analyzer indicates its decomposition at certain
temperature. The Scanning Electron Micrographs of colloidal
platinum nanoparticles were spherical, uniform shape in the
composite. The current-voltage (I-V) characteristics of the PANI and
composites were also studied which indicate a significant decreasing
resistivity than PANI-Platinum after introduction of pt nanoparticles
in the matrix of polyaniline (PANI).
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: This paper is focused on the reference current
calculation in the compensation mode of the active DC traction
substations. The so-called p-q theory of the instantaneous reactive
power is used as theoretical foundation. The compensation goal of
total compensation is taken into consideration for the operation under
both sinusoidal and nonsinusoidal voltage conditions, through the
two objectives of unity power factor and perfect harmonic
cancelation. Four blocks of reference current generation implement
the conceived algorithms and they are included in a specific Simulink
library, which is useful in a DSP dSPACE-based platform working
under Matlab/Simulink. The simulation results validate the
correctness of the implementation and fulfillment of the
compensation tasks.
Abstract: While choosing insulating oil, characteristic features
such as thermal cooling, endurance, efficiency and being
environment-friendly should be considered. Mineral oils are referred
as petroleum-based oil. In this study, vegetable oils investigated as an
alternative insulating liquid to mineral oil. Dissipation factor,
breakdown voltage, relative dielectric constant and resistivity
changes with the frequency and voltage of mineral, rapeseed and nut
oils were measured. Experimental studies were performed according
to ASTM D924 and IEC 60156 standards.
Abstract: This paper presents an application of Artificial Neural
Network (ANN) algorithm for improving power system voltage
stability. The training data is obtained by solving several normal and
abnormal conditions using the Linear Programming technique. The
selected objective function gives minimum deviation of the reactive
power control variables, which leads to the maximization of
minimum Eigen value of load flow Jacobian. The considered reactive
power control variables are switchable VAR compensators, OLTC
transformers and excitation of generators. The method has been
implemented on a modified IEEE 30-bus test system. The results
obtain from the test clearly show that the trained neural network is
capable of improving the voltage stability in power system with a
high level of precision and speed.
Abstract: Durability of Membrane Electrode Assembly for
Proton Exchange Membrane Fuel Cells was evaluated in both steady
state and accelerated decay modes. Steady state mode was carried out
at constant current of 800mA/cm2 for 2500 hours using air as cathode
feed and pure hydrogen as anode feed. The degradation of the cell
voltage was 0.015V after such 2500 hrs operation. The degradation
rate was therefore calculated to be 6uV/hr. Continuously Vigorous
fluctuation of the cell voltage, which was switched between OCV and
0.2V, was employed for the accelerated decay mode. No obvious
change in performance of the MEA was observed after 10000 cycles
of such operation.