Abstract: To focus on the vibration mode of a cone loudspeaker,
which acts as an electroacoustic transducer, excitation experiments
were performed using two types of loudspeaker units: one employing
an impulse hammer and the other a sweep signal. The on-axis sound
pressure frequency properties of the loudspeaker were evaluated, and
the characteristic properties of the loudspeakers were successfully
determined in both excitation experiments. Moreover, under
conditions identical to the experiment conditions, a coupled analysis of
the vibration-acoustics of the cone loudspeaker was performed using
an acoustic analysis software program that considers the impact of
damping caused by air viscosity. The result of sound pressure
frequency properties with the numerical analysis are the most closely
match that measured in the excitation experiments over a wide range
of frequency bands.
Abstract: Maintenance and design engineers have great concern
for the functioning of rotating machineries due to the vibration
phenomenon. Improper functioning in rotating machinery originates
from the damage to rolling element bearings. The status of rolling
element bearings require advanced technologies to monitor their
health status efficiently and effectively. Avoiding vibration during
machine running conditions is a complicated process. Vibration
simulation should be carried out using suitable sensors/ transducers to
recognize the level of damage on bearing during machine operating
conditions. Various issues arising in rotating systems are interlinked
with bearing faults. This paper presents an approach for fault
diagnosis of bearings using neural networks and time/frequencydomain
vibration analysis.
Abstract: This paper describes the development of a DNA-based
nanobiosensor to detect the dengue virus in mosquito using
electrically active magnetic (EAM) nanoparticles as concentrator and
electrochemical transducer. The biosensor detection encompasses
two sets of oligonucleotide probes that are specific to the dengue
virus: the detector probe labeled with the EAM nanoparticles and the
biotinylated capture probe. The DNA targets are double hybridized to
the detector and the capture probes and concentrated from
nonspecific DNA fragments by applying a magnetic field.
Subsequently, the DNA sandwiched targets (EAM-detector probe–
DNA target–capture probe-biotin) are captured on streptavidin
modified screen printed carbon electrodes through the biotinylated
capture probes. Detection is achieved electrochemically by measuring
the oxidation–reduction signal of the EAM nanoparticles. Results
indicate that the biosensor is able to detect the redox signal of the
EAM nanoparticles at dengue DNA concentrations as low as 10
ng/μl.
Abstract: This study investigates the cleaning performance of
high intensity 360 kHz frequency on removal of nano-dimensional
and sub-micron particles from various surfaces, uniformity of the
cleaning tank and run to run variation of cleaning process. The
uniformity of the cleaning tank was measured by two different
methods i.e. 1. ppbTM meter and 2. Liquid Particle Counting (LPC)
technique. The result indicates that the energy was distributed more
uniformly throughout the entire cleaning vessel even at the corners
and edges of the tank when megasonic sweeping technology is
applied. The result also shows that rinsing the parts with 360 kHz
frequency at final rinse gives lower particle counts, hence higher
cleaning efficiency as compared to other frequencies. When
megasonic sweeping technology is applied each piezoelectric
transducers will operate at their optimum resonant frequency and
generates stronger acoustic cavitational force and higher acoustic
streaming velocity. These combined forces are helping to enhance the
particle removal and at the same time improve the overall cleaning
performance. The multiple extractions study was also carried out for
various frequencies to measure the cleaning potential and asymptote
value.
Abstract: The phased-array ultrasound transducer types are
utilities for medical ultrasonography as well as optical imaging.
However, their discontinuity characteristic limits the applications due
to the artifacts contaminated into the reconstructed images. Because
of the effects of the ultrasound pressure field pattern to the echo
ultrasonic waves as well as the optical modulated signal, the side
lobes of the focused ultrasound beam induced by discontinuity of the
phased-array ultrasound transducer might the reason of the artifacts.
In this paper, a simple method in approach of numerical simulation
was used to investigate the limitation of discontinuity of the elements
in phased-array ultrasound transducer and their effects to the
ultrasound pressure field. Take into account the change of ultrasound
pressure field patterns in the conditions of variation of the pitches
between elements of the phased-array ultrasound transducer, the
appropriated parameters for phased-array ultrasound transducer
design were asserted quantitatively.
Abstract: The aim of this work is to present a theoretical analysis of a 2D ultrasound transducer comprised of crossed arrays of metal strips placed on both sides of thin piezoelectric layer (a). Such a structure is capable of electronic beam-steering of generated wavebeam both in elevation and azimuth. In this paper a semi-analytical model of the considered transducer is developed. It is based on generalization of the well-known BIS-expansion method. Specifically, applying the electrostatic approximation, the electric field components on the surface of the layer are expanded into fast converging series of double periodic spatial harmonics with corresponding amplitudes represented by the properly chosen Legendre polynomials. The problem is reduced to numerical solving of certain system of linear equations for unknown expansion coefficients.
Abstract: Thermodynamic properties of liquids under negative pressures are interesting and important in fields of scienceand technology. Here, phase transitions of a thermotropic liquid crystal are investigatedin a range from positive to negative pressures with a metal Berthelot tube using a commercial pressure transducer.Two co-existinglines, namely crystal (Kr) –nematic (N), and isotropic liquid (I) - nematic (N) lines, weredrawn in a pressure - temperature plane. The I-N line was drawn to ca. -5 (MPa).
Abstract: Modulus of elasticity is one of the important
parameters of construction materials, which considerably influence
their deformation properties and which can also be determined by
means of non-destructive test methods like ultrasonic pulse method.
However, measurement results of ultrasonic pulse methods are
influenced by various factors, one of which is the natural frequency
of the transducers. The paper states knowledge about influence of
natural frequency of the transducers (54; 82 and 150kHz) on
ultrasonic pulse velocity and dynamic modulus of elasticity (Young's
Dynamic modulus of elasticity). Differences between ultrasonic pulse
velocity and dynamic modulus of elasticity were found with the same
smallest dimension of test specimen in the direction of sounding and
density their value decreases as the natural frequency of transducers
grew.
Abstract: Fiber reinforced concrete is important material for load bearing structural elements. Usually fibers are homogeneously distributed in a concrete body having arbitrary spatial orientations. At the same time, in many situations, fiber concrete with oriented fibers is more optimal. Is obvious, that is possible to create constructions with oriented short fibers in them, in different ways. Present research is devoted to one of such approaches- fiber reinforced concrete prisms having dimensions 100mm ×100mm ×400mmwith layers of non-homogeneously distributed fibers inside them were fabricated.
Simultaneously prisms with homogeneously dispersed fibers were produced for reference as well. Prisms were tested under four point bending conditions. During the tests vertical deflection at the center of every prism and crack opening were measured (using linear displacements transducers in real timescale). Prediction results were discussed.
Abstract: Experiments were performed in a three-phase bubble column to study variations of bubble rise velocities. The dynamic gas disengagement (DGD) technique and the fast response pressure transducers were utilized to investigate the bubble rise in the column. The superficial gas velocity of large bubbles and small bubbles, the rise velocities of larger and small bubble fractions were studied considering the effect of particle sizes. The results show that the superficial gas velocity associated with large bubbles linearly increase as superficial gas velocity increasing. Particle size has little effect on the both large and small bubble superficial gas velocities. The rise velocities of larger bubble fractions are larger than that of small bubble fractions, and it had different tendency at low and high superficial gas velocities when changing the particle sizes. The rise velocities of small bubble fractions increased and then had a decrease tendency when the particle size became greater.
Abstract: Planar systems of electrodes arranged on both sides of dielectric piezoelectric layer are applied in numerous transducers. They are capable of electronic beam-steering of generated wave both in azimuth and elevation. The wave-beam control is achieved by addressable driving of two-dimensional transducer through proper voltage supply of electrodes on opposite surfaces of the layer. In this paper a semi-analytical method of analysis of the considered transducer is proposed, which is a generalization of the well-known BIS-expansion method. It was earlier exploited with great success in the theory of interdigital transducers of surface acoustic waves, theory of elastic wave scattering by cracks and certain advanced electrostatic problems. The corresponding nontrivial electrostatic problem is formulated and solved numerically.
Abstract: Earphones and headphones, which are compact electro-acoustic transducers, tend to have a lot of acoustic absorption materials and porous materials known as dampers, which often have a large number of extremely small holes and narrow slits to inhibit the resonance of the vibrating system, because the air viscosity significantly affects the acoustic characteristics in such acoustic paths. In order to perform simulations using the finite element method (FEM), it is necessary to be aware of material characteristics such as the impedance and propagation constants of sound absorbing materials and porous materials. The transfer function is widely known as a measurement method for an acoustic tube with such physical properties, but literature describing the measurements at the upper limits of the audible range is yet to be found. The acoustic tube, which is a measurement instrument, must be made narrow, and the distance between the two sets of microphones must be shortened in order to take measurements of acoustic characteristics at higher frequencies. When such a tube is made narrow, however, the characteristic impedance has been observed to become lower than the impedance of air. This paper considers the cause of this phenomenon to be the effect of the air viscosity and describes an FEM analysis of an acoustic tube considering air viscosity to compare to the theoretical formula by including the effect of air viscosity in the theoretical formula for an acoustic tube.
Abstract: We present the design of Analog front end (AFE) low noise pre-amplifier implemented in a high voltage 0.18-µm CMOS technology for a three dimensional ultrasound bio microscope (3D UBM) application. The fabricated chip has 4X16 pre-amplifiers implemented to interface a 2-D array of high frequency capacitive micro-machined ultrasound transducers (CMUT). Core AFE cell consists of a high-voltage pulser in the transmit path, and a low-noise transimpedance amplifier in the receive path. Proposed system offers a high image resolution by the use of high frequency CMUTs with associated high performance imaging electronics integrated together. Performance requirements and the design methods of the high bandwidth transimpedance amplifier are described in the paper. A single cell of transimpedance (TIA) amplifier and the bias circuit occupies a silicon area of 250X380 µm2 and the full chip occupies a total silicon area of 10x6.8 mm².
Abstract: Plenty researches have reported techniques to harvest energy from piezoelectric transducer. In the earlier years, the researches mainly report linear energy harvesting techniques whereby interface circuitry is designed to have input impedance that match with the impedance of the piezoelectric transducer. In recent years non-linear techniques become more popular. The non-linear technique employs voltage waveform manipulation to boost the available-for-extraction energy at the time of energy transfer. The fact that non-linear energy extraction provides larger available-for-extraction energy doesn’t mean the linear energy extraction is completely obsolete. In some scenarios, such as where initial power is not available, linear energy extraction is still preferred. A modified Buck Boost circuit which is capable of harvesting piezoelectric energy using both linear and non-linear techniques is reported in this paper. Efficiency of at least 64% can be achieved using this circuit. For linear extraction, the modified Buck Boost circuit is controlled using a fix frequency and duty cycle clock. A voltage sensor and a pulse generator are added as the controller for the non-linear extraction technique.
Abstract: The paper presents the multi-element synthetic
transmit aperture (MSTA) method with a small number of elements
transmitting and all elements apertures in medical ultrasound
imaging. As compared to the other methods MSTA allows to
increase the system frame rate and provides the best compromise
between penetration depth and lateral resolution.
In the experiments a 128-element linear transducer array with
0.3 mm pitch excited by a burst pulse of 125 ns duration were used.
The comparison of 2D ultrasound images of tissue mimicking
phantom obtained using the STA and the MSTA methods is
presented to demonstrate the benefits of the second approach. The
results were obtained using SA algorithm with transmit and receive
signals correction based on a single element directivity function.
Abstract: In this work, we try to find the best setting
of Computational Fluid Dynamic solver available for the problems in
the field of supersonic internal flows. We used the supersonic air-toair
ejector to represent the typical problem in focus. There are
multiple oblique shock waves, shear layers, boundary layers
and normal shock interacting in the supersonic ejector making this
device typical in field of supersonic inner flows. Modeling of shocks
in general is demanding on the physical model of fluid, because
ordinary conservation equation does not conform to real conditions in
the near-shock region as found in many works. From these reasons,
we decided to take special care about solver setting in this article by
means of experimental approach of color Schlieren pictures and
pneumatic measurement. Fast pressure transducers were used to
measure unsteady static pressure in regimes with normal shock in
mixing chamber. Physical behavior of ejector in several regimes is
discussed. Best choice of eddy-viscosity setting is discussed on the
theoretical base. The final verification of the k-ω SST is done on the
base of comparison between experiment and numerical results.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: Extensive wind tunnel tests have been conducted to
investigate the unsteady flow field over and behind a 2D model of a
660 kW wind turbine blade section in pitching motion. The surface
pressure and wake dynamic pressure variation at a distance of 1.5
chord length from trailing edge were measured by pressure
transducers during several oscillating cycles at 3 reduced frequencies
and oscillating amplitudes. Moreover, form drag and linear
momentum deficit are extracted and compared at various conditions.
The results show that the wake velocity field and surface pressure of
the model have similar behavior before and after the airfoil beyond
the static stall angle of attack. In addition, the effects of reduced
frequency and oscillation amplitudes are discussed.
Abstract: Functional gastrointestinal disorders affect millions of people spread all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. Aim of this study is, therefore, to develop a diagnostic system for the functional gastrointestinal disorders based on ultrasound technique, which can quantify the characteristic above related to the rigidity of the gastrointestinal tract well. Ultrasound system was designed. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders (Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normal specimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens (0.2±0.1Vp-p) at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens (0.1±0.0Vp-p). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals near to the gastrointestinal tract well for the patient group (2.6±0.3Vp-p) were generally higher than those in normal group (0.1±0.2Vp-p). Here, maximum reflective signals was appeared at 20mm depth approximately from abdominal skin for all human subjects, corresponding to the location of the boundary layer close to gastrointestinal tract well. These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.
Abstract: Planar systems of electrodes arranged on both sides of dielectric piezoelectric layer are applied in numerous transducers. They are capable of electronic beam-steering of generated wave both in azimuth and elevation. The wave-beam control is achieved by addressable driving of two-dimensional transducer through proper voltage supply of electrodes on opposite surfaces of the layer. In this paper a semi-analytical method of analysis of the considered transducer is proposed, which is a generalization of the well-known BIS-expansion method. It was earlier exploited with great success in the theory of interdigital transducers of surface acoustic waves, theory of elastic wave scattering by cracks and certain advanced electrostatic problems. The corresponding nontrivial electrostatic problem is formulated and solved numerically.