Abstract: Heterogeneous catalysis is vital for a number of
chemical, refinery and pollution control processes. The use of
catalyst pellets of hollow cylindrical shape provide several distinct
advantages over other common shapes, and can therefore help to
enhance conversion levels in reactors. A better utilization of the
catalytic material is probably most notable of these features due to
the absence of the pellet core, which helps to significantly lower the
effect of the internal transport resistance. This is reflected in the
enhancement of the effectiveness factor. For the case of the first order
irreversible kinetics, a substantial increase in the effectiveness factor
can be obtained by varying shape parameters. Important shape
parameters of a finite hollow cylinder are the ratio of the inside to the
outside radii (κ) and the height to the diameter ratio (γ). A high value
of κ the generally helps to enhance the effectiveness factor. On the
other hand, lower values of the effectiveness factors are obtained
when the dimension of the height and the diameter are comparable.
Thus, the departure of parameter γ from the unity favors higher
effectiveness factor. Since a higher effectiveness factor is a measure
of a greater utilization of the catalytic material, higher conversion
levels can be achieved using the hollow cylindrical pellets possessing
optimized shape parameters.
Abstract: The improvement of a filer case utilized to purify the
let-out smoke and smell in the production of Benjarong Ceramic is
studied through Participatory Action Research (PAR). This research
is aimed to protect smell, dirty smoke, and air pollution which are
effects of incomplete combustion in the production of Benjarong
ceramic. This research was conducted at Jongjint Benjarong Ceramic
Factory in Plai Bang, Bang Kruai, Nonthaburi Province,Thailand,
also 12 employees were interviewed for data collection. All collected
data were analyzed to develop and create solution to protect smoke
and smell pollution from Benjarong ceramic production.
The results revealed that the employees who have used the
developed filer cases are moderately satisfied. In addition to the
efficiency of developed smoke-and-smell filer cases, it was found
that Overall, the respondents were satisfied moderately with
efficiency of modified smoke and smell filter cases.
Abstract: A long-term campaign for monitoring the
concentration of atmospheric Particulate Matter (PM) was conducted
at multiple sites located in the center and suburbs of the Tokyo
Metropolitan Area in Japan. The concentration of fine PM has shown a
declining trend over the last two decades. A positive matrix
factorization model elucidated that the contribution of combustion
sources was drastically reduced. In Japan, the regulations on vehicle
exhaust emissions were phased in and gradually tightened over the last
two decades, which has triggered a notable reduction in PM emissions
from automobiles and has contributed to the mitigation of the problem
of fine PM pollution.
Abstract: Petrol Fuel Station (PFS) has potential hazards to the
people, asset, environment and reputation of an operating company.
Fire hazards, static electricity air pollution evoked by aliphatic and
aromatic organic compounds are major causes of accident/incident
occurrence at fuel station. Activities such as carelessness,
maintenance, housekeeping, slips trips and falls, transportation
hazard, major and minor injuries, robbery and snake bites has a
potential to create unsafe conditions. The level of risk of these
hazards varies according to location and country. The emphasis on
safety considerations by the government is variable all around the
world. Developed countries safety records are much better as
compared to developing countries safety statistics. There is no
significant approach available to highlight the unsafe acts and unsafe
conditions during operation and maintenance of fuel station. Fuel
station is the most commonly available facilities that contain
flammable and hazardous materials. Due to continuous operation of
fuel station they pose various hazards to people, environment and
assets of an organization. To control these hazards, there is a need for
specific approach. PFS operation is unique as compared to other
businesses. For smooth operations it demands an involvement of
operating company, contractor and operator group. This study will
focus to address hazard contributing factors that have a potential to
make PFS operation risky. One year data collected, 902 activities
analyzed, comparisons were made to highlight significant
contributing factors. The study will provide help and assistance to
PFS outlet marketing companies to make their fuel station operation
safer. It will help health safety and environment (HSE) professionals
to arrest the gap available related to safety matters at PFS.
Abstract: The main purpose of this research is the calculation of implicit prices of the environmental level of air quality in the city of Moscow on the basis of housing property prices. The database used contains records of approximately 20 thousand apartments and has been provided by a leading real estate agency operating in Russia. The explanatory variables include physical characteristics of the houses, environmental (industry emissions), neighbourhood sociodemographic and geographic data: GPS coordinates of each house. The hedonic regression results for ecological variables show «negative» prices while increasing the level of air contamination from such substances as carbon monoxide, nitrogen dioxide, sulphur dioxide, and particles (CO, NO2, SO2, TSP). The marginal willingness to pay for higher environmental quality is presented for linear and log-log models.
Abstract: Following the research in the Department of environmental engineering in Faculty of mechanical engineering on Technical University of Kosice and experiences with electrocoagulation style of disposal waste water, there were designed and partly examining the equipment of two stage revitalization on the standing and little fusible water of tenet electrolysis on the little tarns. With the cooperation with vet experts was that manners prove and it is innocuous for animals, during which time cyanobacteria are totally paralyzed. For the implementation of science and research results have been obtained by means EU funds for structural development.
Abstract: Most often the contaminants are not taken seriously into consideration, and this behavior comes out directly from the lack of monitoring and professional reporting about pollution in the printing facilities in Serbia. The goal of planned and systematic ozone measurements in ambient air of the screen printing facilities in Novi Sad is to examine of its impact on the employees health, and to track trends in concentration. In this study, ozone concentrations were determined by using discontinuous and continuous method during the automatic and manual screen printing process. Obtained results indicates that the average concentrations of ozone measured during the automatic process were almost 3 to 28 times higher for discontinuous and 10 times higher for continuous method (1.028 ppm) compared to the values prescribed by OSHA. In the manual process, average concentrations of ozone were within prescribed values for discontinuous and almost 3 times higher for continuous method (0.299 ppm).
Abstract: In recent years, there has been an increasing interest in using daylight to save energy in buildings. In tropical regions, daylighting is always an energy saver. On the other hand, daylight provides visual comfort. According to standards, it shows that many criteria should be taken into consideration in order to have daylight utilization and visual comfort. The current standard in Malaysia, MS 1525 does not provide sufficient guideline. Hence, more research is needed on daylight performance. If architects do not consider daylight design, it not only causes inconvenience in working spaces but also causes more energy consumption as well as environmental pollution. This research had surveyed daylight performance in 5 selected office buildings from different area of Malaysian through experimental method. Several parameters of daylight quality such as daylight factor, surface luminance and surface luminance ratio were measured in different rooms in each building. The result of this research demonstrated that most of the buildings were not designed for daylight utilization. Therefore, it is very important that architects follow the daylight design recommendation to reduce consumption of electric power for artificial lighting while the sufficient quality of daylight is available.
Abstract: Electronic nose (array of chemical sensors) are widely
used in food industry and pollution control. Also it could be used to
locate or detect the direction of the source of emission odors. Usually
this task is performed by electronic nose (ENose) cooperated with
mobile vehicles, but when a source is instantaneous or surrounding is
hard for vehicles to reach, problem occurs. Thus a method for
stationary ENose to detect the direction of the source and locate the
source will be required. A novel method which uses the ratio between
the responses of different sensors as a discriminant to determine the
direction of source in natural wind surroundings is presented in this
paper. The result shows that the method is accurate and easily to be
implemented. This method could be also used in movably, as an
optimized algorithm for robot tracking source location.
Abstract: Water pollution assessment problems arise frequently
in environmental science. In this research, a finite difference method
for solving the one-dimensional steady convection-diffusion equation
with variable coefficients is proposed; it is then used to optimize
water treatment costs.
Abstract: Pentachlorophenol (PCP) is a polychlorinated
aromatic compound that is widespread in industrial effluents and is
considered to be a serious pollutant. Among the variety of industrial
effluents encountered, effluents from tanning industry are very
important and have a serious pollution potential. PCP is also formed
unintentionally in effluents of paper and pulp industries. It is highly
persistent in soils and is lethal to a wide variety of beneficial
microorganisms and insects, human beings and animals. The natural
processes that breakdown toxic chemicals in the environment have
become the focus of much attention to develop safe and environmentfriendly
deactivation technologies. Microbes and plants are among
the most important biological agents that remove and degrade waste
materials to enable their recycling in the environment. The present
investigation was carried out with the aim of developing a microbial
system for bioremediation of PCP polluted soils. A number of plant
species were evaluated for their ability to tolerate different
concentrations of pentachlorophenol (PCP) in the soil. The
experiment was conducted for 30 days under pot culture conditions.
The toxic effect of PCP on plants was studied by monitoring seed
germination, plant growth and biomass. As the concentration of PCP
was increased to 50 ppm, the inhibition of seed germination, plant
growth and biomass was also increased. Although PCP had a
negative effect on all plant species tested, maize and groundnut
showed the maximum tolerance to PCP. Other tolerating crops
included wheat, safflower, sunflower, and soybean. From the
rhizosphere soil of the tolerant seedlings, as many as twenty seven
PCP tolerant bacteria were isolated. From soybean, 8; sunflower, 3;
safflower 8; maize 2; groundnut and wheat, 3 each isolates were
made. They were screened for their PCP degradation potentials.
HPLC analyses of PCP degradation revealed that the isolate MAZ-2
degraded PCP completely. The isolate MAZ-1 was the next best
isolate with 90 per cent PCP degradation. These strains hold promise
to be used in the bioremediation of PCP polluted soils.
Abstract: The increased use of biodiesel implies variations on both greenhouse gases and air pollutant emissions. Some studies point out that the use of biodiesel blends on diesel can help in controlling air pollution and promote a reduction of CO2 emissions. Reductions on PM, SO2, VOC and CO emissions are also expected, however NOx emissions may increase, which may potentiate O3 formation. This work aims to assess the impact of the biodiesel use on air quality, through a numerical modeling study, taking the Northern region of Portugal as a case study. The emission scenarios are focused on 2008 (baseline year) and 2020 (target year of Renewable Energy Directive-RED) and on three biodiesel blends (B0, B10 and B20). In a general way the use of biodiesel by 2020 will reduce the CO2 and air pollutants emissions in the Northern Portugal, improving air quality. However it will be in a very small extension.
Abstract: The pollution of sediments sampled from the North
Port by polycyclic aromatic hydrocarbons (PAHs) was investigated.
Concentrations of PAHs estimated in the port sediments ranged from
199 to 2851.2 μg/kg dw. The highest concentration was found which
is closed to the Berth line, this locations affected by intensive
shipping activities and Land based runoff and they were dominated
by the high molecular weight PAHs (4–6- rings). Source
identification showed that PAHs originated mostly from the
pyrogenic source either from the combustion of fossil fuels, grass,
wood and coal (majority of the samples). Ecological Risk Assessment
on the port sediments presented that slightly adverse ecological
effects to biological community are expected to occur at the vicinity
of the stations 1 and 4. Thus PAHs are not considered as pollutants of
concern in the North Port.
Abstract: Smoke from domestic wood burning has been
identified as a major contributor to air pollution, motivating detailed
emission measurements under controlled conditions. A series of
experiments was performed to characterise the emissions from wood
combustion in a fireplace and in a woodstove of two common species
of trees grown in Spain: Pyrenean oak (Quercus pyrenaica) and
black poplar (Populus nigra). Volatile organic compounds (VOCs) in
the exhaust emissions were collected in Tedlar bags, re-sampled in
sorbent tubes and analysed by thermal desorption-gas
chromatography-flame ionisation detection. Pyrenean oak presented
substantially higher emissions in the woodstove than in the fireplace,
for the majority of compounds. The opposite was observed for
poplar. Among the 45 identified species, benzene and benzenerelated
compounds represent the most abundant group, followed by
oxygenated VOCs and aliphatics. Emission factors obtained in this
study are generally of the same order than those reported for
residential experiments in the USA.
Abstract: Environmental pollution problems have been globally
main concern in all fields including economy, society and culture into
the 21st century. Beginning with the Kyoto Protocol, the reduction on
the emissions of greenhouse gas such as CO2 and SOX has been a
principal challenge of our day. As most buildings unlike durable goods
in other industries have a characteristic and long life cycle, they
consume energy in quantity and emit much CO2. Thus, for green
building construction, more research is needed to reduce the CO2
emissions at each stage in the life cycle. However, recent studies are
focused on the use and maintenance phase. Also, there is a lack of
research on the initial design stage, especially the structure design.
Therefore, in this study, we propose an optimal design plan
considering CO2 emissions and cost in composite buildings
simultaneously by applying to the structural design of actual building.
Abstract: This paper presents a computer simulation model based on system dynamics methodology for analyzing the dynamic characteristics of input energy structure in agriculture and Bangladesh is used here as a case study for model validation. The model provides an input energy structure linking the major energy flows with human energy and draft energy from cattle as well as tractors and/or power tillers, irrigation, chemical fertilizer and pesticide. The evaluation is made in terms of different energy dependent indicators. During the simulation period, the energy input to agriculture increased from 6.1 to 19.15 GJ/ha i.e. 2.14 fold corresponding to energy output in terms of food, fodder and fuel increase from 71.55 to 163.58 GJ/ha i.e. 1.28 fold from the base year. This result indicates that the energy input in Bangladeshi agricultural production is increasing faster than the energy output. Problems such as global warming, nutrient loading and pesticide pollution can associate with this increasing input. For an assessment, a comparative statement of input energy use in agriculture of developed countries (DCs) and least developed countries (LDCs) including Bangladesh has been made. The performance of the model is found satisfactory to analyze the agricultural energy system for LDCs
Abstract: Transesterified vegetable oils (biodiesel) are promising alternative fuel for diesel engines. Used vegetable oils are disposed from restaurants in large quantities. But higher viscosity restricts their direct use in diesel engines. In this study, used cooking oil was dehydrated and then transesterified using an alkaline catalyst. The combustion, performance and emission characteristics of Used Cooking oil Methyl Ester (UCME) and its blends with diesel oil are analysed in a direct injection C.I. engine. The fuel properties and the combustion characteristics of UCME are found to be similar to those of diesel. A minor decrease in thermal efficiency with significant improvement in reduction of particulates, carbon monoxide and unburnt hydrocarbons is observed compared to diesel. The use of transesterified used cooking oil and its blends as fuel for diesel engines will reduce dependence on fossil fuels and also decrease considerably the environmental pollution.
Abstract: This paper presents an inexpensive and effective temperature-controlled chamber for temperature environment tests of Organic Light Emitting Diode (OLED) panels. The proposed chamber is a compact warmer and cooler with an exact temperature control system. In the temperature-controlled space of the chamber, thermoelectric modules (TEMs) are utilized to cool or to heat OLED panels, novel fixtures are designed to flexibly clamp the OLED panels of different size, and special connectors for wiring between the OLED panels and the test instrument are supplied. The proposed chamber has the following features. (1) The TEMs are solid semi-conductive devices, so they operate without noise and without pollution. (2) The volume of the temperature-controlled space of the chamber about 160mm*160mm*120mm, so the chamber are compact and easy to move. (3) The range of the controlled temperatures is from -10 oC to +80 oC, and the precision is ?0.5 oC. (4) The test instrument can conveniently and easily measure the OLED panels via the novel fixtures and special connectors. In addition to a constant temperature being maintained in the chamber, a temperature shock experiments can run for a long time. Therefore, the chamber will be convenient and useful for temperature environment tests of OLED panels.
Abstract: In this study, a 3D combustion chamber was simulated
using FLUENT 6.32. Aims to obtain accurate information about the
profile of the combustion in the furnace and also check the effect of
oxygen enrichment on the combustion process. Oxygen enrichment is
an effective way to reduce combustion pollutant. The flow rate of air
to fuel ratio is varied as 1.3, 3.2 and 5.1 and the oxygen enriched
flow rates are 28, 54 and 68 lit/min. Combustion simulations
typically involve the solution of the turbulent flows with heat
transfer, species transport and chemical reactions. It is common to
use the Reynolds-averaged form of the governing equation in
conjunction with a suitable turbulence model. The 3D Reynolds
Averaged Navier Stokes (RANS) equations with standard k-ε
turbulence model are solved together by Fluent 6.3 software. First
order upwind scheme is used to model governing equations and the
SIMPLE algorithm is used as pressure velocity coupling. Species
mass fractions at the wall are assumed to have zero normal
gradients.Results show that minimum mole fraction of CO2 happens
when the flow rate ratio of air to fuel is 5.1. Additionally, in a fixed
oxygen enrichment condition, increasing the air to fuel ratio will
increase the temperature peak. As a result, oxygen-enrichment can
reduce the CO2 emission at this kind of furnace in high air to fuel
rates.
Abstract: A good green building design project, designers should consider not only energy consumption, but also healthy and comfortable needs of inhabitants. In recent years, the Taiwan government paid attentions on both carbon reduction and indoor air quality issues, which be presented in the legislation of Building Codes and other regulations. Taiwan located in hot and humid climates, dampness in buildings leads to significant microbial pollution and building damage. This means that the high temperature and humidity present a serious indoor air quality issue. The interactions between vapor transfers and energy fluxes are essential for the whole building Heat Air and Moisture (HAM) response. However, a simulation tool with short calculation time, property accuracy and interface is needed for practical building design processes. In this research, we consider the vapor transfer phenomenon of building materials as well as temperature and humidity and energy consumption in a building space. The simulation bases on the EMPD method, which was performed by EnergyPlus, a simulation tool developed by DOE, to simulate the indoor moisture variation in a one-zone residential unit based on the Effective Moisture Penetration Depth Method, which is more suitable for practical building design processes.