Abstract: Encryption protects communication partners from
disclosure of their secret messages but cannot prevent traffic analysis
and the leakage of information about “who communicates with
whom". In the presence of collaborating adversaries, this linkability
of actions can danger anonymity. However, reliably providing
anonymity is crucial in many applications. Especially in contextaware
mobile business, where mobile users equipped with PDAs
request and receive services from service providers, providing
anonymous communication is mission-critical and challenging at the
same time. Firstly, the limited performance of mobile devices does
not allow for heavy use of expensive public-key operations which are
commonly used in anonymity protocols. Moreover, the demands for
security depend on the application (e.g., mobile dating vs. pizza
delivery service), but different users (e.g., a celebrity vs. a normal
person) may even require different security levels for the same
application. Considering both hardware limitations of mobile devices
and different sensitivity of users, we propose an anonymity
framework that is dynamically configurable according to user and
application preferences. Our framework is based on Chaum-s mixnet.
We explain the proposed framework, its configuration
parameters for the dynamic behavior and the algorithm to enforce
dynamic anonymity.
Abstract: The gas safety management system using an
intelligent gas meter we proposed is to monitor flow and
pressure of gas, earthquake, temperature, smoke and leak of
methane. Then our system takes safety measures to protect a
serious risk by the result of an event, to communicate with a
wall-pad including a gateway by zigbee network in buildings
and to report the event to user by the safety management
program in a server. Also, the inner cutoff valve of an
intelligent gas meter is operated if any event occurred or
abnormal at each sensor.
Abstract: In this study, noise characteristics of structure were analyzed in an effort to reduce noise passing through an opening of an
enclosure surrounding the structure that generates noise. Enclosures
are essential measure to protect noise propagation from operating machinery. Access openings of the enclosures are important path of noise leakage. First, noise characteristics of structure were analyzed
and feed-forward noise control was performed using simulation in
order to reduce noise passing through the opening of enclosure, which
surrounds a structure generating noise. We then implemented a
feed-forward controller to actively control the acoustic power through
the opening. Finally, we conducted optimization of placement of the
reference sensors for several cases of the number of sensors. Good
control performances were achieved using the minimum number of microphones arranged an optimal placement.
Abstract: This article simulates the wind generator set which has
two fault bearing collar rail destruction and the gear box oil leak fault.
The electric current signal which produced by the generator, We use
Empirical Mode Decomposition (EMD) as well as Fast Fourier
Transform (FFT) obtains the frequency range-s signal figure and
characteristic value. The last step is use a kind of Artificial Neural
Network (ANN) classifies which determination fault signal's type and
reason. The ANN purpose of the automatic identification wind
generator set fault..
Abstract: This work aims to reduce the read power consumption
as well as to enhance the stability of the SRAM cell during the read
operation. A new 10-transisor cell is proposed with a new read
scheme to minimize the power consumption within the memory core.
It has separate read and write ports, thus cell read stability is
significantly improved. A 16Kb SRAM macro operating at 1V
supply voltage is demonstrated in 65 nm CMOS process. Its read
power consumption is reduced to 24% of the conventional design.
The new cell also has lower leakage current due to its special bit-line
pre-charge scheme. As a result, it is suitable for low-power mobile
applications where power supply is restricted by the battery.
Abstract: Laboratory classes in Electrical Engineering are often hampered by safety issues, as students have to work on high voltage lines. One solution is to make use of virtual laboratory simulations, to help students understand the concepts taught in their coursework. In this context, we have conceived and implemented virtual lab experiments in connection with the study of earthing arrangements. In this work, software was developed, which aid student in understanding the working of a residual current device (RCD) in a TT earthing system. Various parameters, such as the earthing resistances, leakage currents and harmonics were included for a TT system with RCD connection.
Abstract: For a quick and accurate calculation of spatial neutron
distribution in nuclear power reactors 3D nodal codes are usually
used aiming at solving the neutron diffusion equation for a given
reactor core geometry and material composition. These codes use a
second order polynomial to represent the transverse leakage term. In
this work, a nodal method based on the well known nodal expansion
method (NEM), developed at COPPE, making use of this polynomial
expansion was modified to treat the transverse leakage term for the
external surfaces of peripheral reflector nodes.
The proposed method was implemented into a computational
system which, besides solving the diffusion equation, also solves the
burnup equations governing the gradual changes in material
compositions of the core due to fuel depletion. Results confirm the
effectiveness of this modified treatment of peripheral nodes for
practical purposes in PWR reactors.
Abstract: This paper presents the experimental results on
ageing deterioration of silicone rubber outdoor polymer insulator
under salt water dip wheel test based on IEC 62217. In order to comparison effect of chemical contents, silicone rubber outdoor
polymer insulators having same configuration and leakage distant
from two manufactures were tested together continuously 30,000 test cycles. Many discharge activities were observed in during the test.
After 30,000 test cycles, in spite of same configuration, differences in
degree of surface aging were observed. Physical analysis such as
decreasing in hydrophobicity and increasing in hardness
measurement were measured on two-type tested specimen surface in order to confirm degree of surface ageing. Furthermore, chemical
analysis by ATR-FTIR to diagnose the chemical change of tested
specimen surface was conducted to confirm the physical analysis results.
Abstract: In this paper, FinFET devices are analyzed with
emphasis on sub-threshold leakage current control. This is achieved
through proper biasing of the back gate, and through the use of
asymmetric work functions for the four terminal FinFET devices. We
are also examining different configurations of multiplexers and XOR
gates using transistors of symmetric and asymmetric work functions.
Based on extensive characterization data for MUX circuits, our
proposed configuration using symmetric devices lead to leakage
current and delay improvements of 65% and 47% respectively
compared to results in the literature. For XOR gates, a 90%
improvement in the average leakage current is achieved by using
asymmetric devices. All simulations are based on a 25nm FinFET
technology using the University of Florida UFDG model.
Abstract: In this article the influence of higher frequency effects
in addition to a special damper design on the electrical behavior of a
synchronous generator main exciter machine is investigated. On the
one hand these machines are often highly stressed by harmonics from
the bridge rectifier thus facing additional eddy current losses. On the
other hand the switching may cause the excitation of dangerous
voltage peaks in resonant circuits formed by the diodes of the
rectifier and the commutation reactance of the machine. Therefore
modern rotating exciters are treated like synchronous generators
usually modeled with a second order equivalent circuit. Hence the
well known Standstill Frequency Response Test (SSFR) method is
applied to a test machine in order to determine parameters for the
simulation. With these results it is clearly shown that higher
frequencies have a strong impact on the conventional equivalent
circuit model. Because of increasing field displacement effects in the
stranded armature winding the sub-transient reactance is even smaller
than the armature leakage at high frequencies. As a matter of fact this
prevents the algorithm to find an equivalent scheme. This issue is
finally solved using Laplace transfer functions fully describing the
transient behavior at the model ports.
Abstract: A simple microstructure optical fiber design based on an octagonal cladding structure is presented for simultaneously controlling dispersion and leakage properties. The finite difference method with anisotropic perfectly matched boundary layer is used to investigate the guiding properties. It is demonstrated that octagonal photonic crystal fibers with four rings can assume negative ultra-flattened dispersion of -19 + 0.23 ps/nm/km in the wavelength range of 1.275 μm to 1.68 μm, nearly zero ultra-flattened dispersion of 0 ± 0.40 ps/nm/km in a 1.38 to 1.64 μm, and low confinement losses less than 10-3 dB/km in the entire band of interest.
Abstract: Bond graph models of an electrical transformer including
the nonlinear saturation are presented. The transformer
using electrical and magnetic circuits are modelled. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two windings using the properties of a bond graph. The
equivalence between electrical and magnetic variables is given.
The modelling and analysis using this methodology to three phase
power transformers can be extended.
Abstract: In the modern construction practices, industrial wastes
or by-products are largely used as raw materials in cement and
concrete. These impart many benefits to the environment and bringabout
an economic impact because the cost of waste disposal is
constantly increasing due to strict environmental regulations. It was
reported in literature that the leakage of oil onto concrete element in
older cement grinding unit resulted in concrete with greater resistance
to freezing and thawing. This effect was thought to be similar to
adding an air-entraining chemical admixture to concrete. This paper
presents an investigation on the load deflection behaviour and crack
patterns of reinforced concrete (RC) beams subjected to four point
loading. Ten 120x260x1900 mm beams were cast with 100%
ordinary Portland cement (OPC) concrete, 20% fly ash (FA) and 20%
rice husk ash (RHA) blended cement concrete. 0.15% dosage of
admixtures (used engine oil, new engine oil, and superplasticizer)
was used throughout the experiment. Results show that OPC and
OPC/RHA RC beams containing used engine oil and superplasticizer
exhibit higher capacity, 18-26% than their corresponding control
mix.
Abstract: The COSvd Ciphers has been proposed by Filiol and others (2004). It is a strengthened version of COS stream cipher family denoted COSvd that has been adopted for at least one commercial standard. We propose a distinguish attack on this version, and prove that, it is distinguishable from a random stream. In the COSvd Cipher used one S-Box (10×8) on the final part of cipher. We focus on S-Box and use weakness this S-Box for distinguish attack. In addition, found a leak on HNLL that the sub s-boxes don-t select uniformly. We use this property for an Improve distinguish attack.
Abstract: The contact width is important design parameter for
optimizing the design of new metal gasket for asbestos substitution
gasket. The contact width is found have relationship with the helium
leak quantity. In the increasing of axial load value, the helium leak
quantity is decreasing and the contact width is increasing. This study
provides validity method using simulation analysis and the result is
compared to experimental using pressure sensitive paper. The results
denote similar trend data between simulation and experimental result.
Final evaluation is determined by helium leak quantity to check
leakage performance of gasket design. Considering the phenomena of
position change on the convex contact, it can be developed the
optimization of gasket design by increasing contact width.
Abstract: In order to provide accurate heart rate variability
indices of sympathetic and parasympathetic activity, the low
frequency and high frequency components of an RR heart rate signal
must be adequately separated. This is not always possible by just
applying spectral analysis, as power from the high and low frequency
components often leak into their adjacent bands. Furthermore,
without the respiratory spectra it is not obvious that the low
frequency component is not another respiratory component, which
can appear in the lower band. This paper describes an adaptive filter,
which aids the separation of the low frequency sympathetic and high
frequency parasympathetic components from an ECG R-R interval
signal, enabling the attainment of more accurate heart rate variability
measures. The algorithm is applied to simulated signals and heart rate
and respiratory signals acquired from an ambulatory monitor
incorporating single lead ECG and inductive plethysmography
sensors embedded in a garment. The results show an improvement
over standard heart rate variability spectral measurements.
Abstract: Skip cycle is a working strategy for spark ignition
engines, which allows changing the effective stroke of an engine
through skipping some of the four stroke cycles. This study proposes
a new mechanism to achieve the desired skip-cycle strategy for
internal combustion engines. The air and fuel leakage, which occurs
through the gas exchange, negatively affects the efficiency of the
engine at high speeds and loads. An absolute sealing is assured by
direct use of poppet valves, which are kept in fully closed position
during the skipped mode. All the components of the mechanism were
designed according to the real dimensions of the Anadolu Motor's
gasoline engine and modeled in 3D by means of CAD software. As
the mechanism operates in two modes, two dynamically equivalent
models are established to obtain the force and strength analysis for
critical components.
Abstract: There are a many of needs for the development of
SiC-based hydrogen sensor for harsh environment applications. We
fabricated and investigated Pd/Ta2O5/SiC-based hydrogen sensors
with MOS capacitor structure for high temperature process monitoring
and leak detection applications in such automotive, chemical and
petroleum industries as well as direct monitoring of combustion
processes. In this work, we used silicon carbide (SiC) as a substrate to
replace silicon which operating temperatures are limited to below
200°C. Tantalum oxide was investigated as dielectric layer which has
high permeability for hydrogen gas and high dielectric permittivity,
compared with silicon dioxide or silicon nitride. Then, electrical
response properties, such as I-V curve and dependence of capacitance
on hydrogen concentrations were analyzed in the temperature ranges
of room temperature to 500°C for performance evaluation of the
sensor.
Abstract: Due to memory leaks, often-valuable system memory
gets wasted and denied for other processes thereby affecting the
computational performance. If an application-s memory usage
exceeds virtual memory size, it can leads to system crash. Current
memory leak detection techniques for clusters are reactive and
display the memory leak information after the execution of the
process (they detect memory leak only after it occur).
This paper presents a Dynamic Memory Monitoring Agent
(DMMA) technique. DMMA framework is a dynamic memory leak
detection, that detects the memory leak while application is in
execution phase, when memory leak in any process in the cluster is
identified by DMMA it gives information to the end users to enable
them to take corrective actions and also DMMA submit the affected
process to healthy node in the system. Thus provides reliable service
to the user. DMMA maintains information about memory
consumption of executing processes and based on this information
and critical states, DMMA can improve reliability and
efficaciousness of cluster computing.
Abstract: This paper presents the simulation the results of
electric field and potential distributions along surface of silicone
rubber polymer insulators. Near the same leakage distance subjected
to 15 kV in 50 cycle salt fog ageing test, alternate sheds silicone
rubber polymer insulator showed better contamination performance
than straight sheds silicone rubber polymer insulator. Severe surface
ageing was observed on the straight sheds insulator. The objective of
this work is to elucidate that electric field distribution along straight
sheds insulator higher than alternate shed insulator in salt fog ageing
test. Finite element method (FEM) is adopted for this work. The
simulation results confirmed the experimental data, as well.