Electric Field and Potential Distributions along Surface of Silicone Rubber Polymer Insulators Using Finite Element Method

This paper presents the simulation the results of electric field and potential distributions along surface of silicone rubber polymer insulators. Near the same leakage distance subjected to 15 kV in 50 cycle salt fog ageing test, alternate sheds silicone rubber polymer insulator showed better contamination performance than straight sheds silicone rubber polymer insulator. Severe surface ageing was observed on the straight sheds insulator. The objective of this work is to elucidate that electric field distribution along straight sheds insulator higher than alternate shed insulator in salt fog ageing test. Finite element method (FEM) is adopted for this work. The simulation results confirmed the experimental data, as well.




References:
[1] CIGRE TF33.04.07, "Natural and Artificial Ageing and Pollution
Testing of Polymer Insulators", CIGRE Pub. 142, June 1999.
[2] G. G. Karady, H. M. Schneider and F. A. M. Rizk, "Review of CIGRE
and IEEE Research into Pollution Performance of Non Ceramic
Insulators: Field Ageing Effects and Laboratory Test Techniques",
CIGRE 1994 Session Paper No. 33 - 103, August/September 1994.
[3] I. Gutman, R. Harting, R. Matsuoka and K. Kondo, "Experience with
IEC 1109 1000h Salt Fog Ageing Test for Composite Insulators",
IEEE Electrical Insulation Magazine, Vol. 13, No. 3, May/June 1997,
pp. 36 - 39.
[4] T. Zhao and R. A. Bernstorf, "Ageing Tests of Polymeric Housing
Materials for Non - ceramic Insulators", IEEE Electrical Insulation
Magazine, Vol. 14, No. 2, March/April 1998, pp. 26 - 33.
[5] R. S. Gorur, E. A. Cherney and R. Hackam, "A Comparative Study of
Polymer Insulating Materials under Salt Fog Test", IEEE Trans. on
Electrical Insulation, Vol. EI - 21, No. 2, April 1986, pp. 175 - 182.
[6] M. C. Arklove and J. C. G. Wheeler, "Salt - Fog Testing of Composite
Insulators", 7th Int. Conf. on Dielctric Material, Measurements and
Applications, Conf. Pub. No. 430, September 1996, pp. 296 - 302.
[7] S. H. Kim, R. Hackam, "Influence of Multiple Insulator Rods on
Potential and Electric Field Distributions at Their Surface" , Int. Conf.
on Electrical Insulation and Dielectric Phenomena 1994, October 1994,
pp. 663 - 668.
[8] B. Marungsri, H. Shinokubo, R. Matsuoka and S. Kumagai, "Effect of
Specimen Configuration on Deterioration of Silicone Rubber for
Polymer Insulators in Salt Fog Ageing Test", IEEE Trans. on DEI, Vol.
13, No. 1 , February 2006, pp. 129 - 138.
[9] S. Sangkhasaad, "High Voltage Engineering", 3nd edition, Printed in
Bangkok, Thailand, March 2006 (in Thai).
[10] C. N. Kim, J. B. Jang, X. Y. Huang, P. K. Jiang and H. Kim, "Finite
element analysis of electric field distribution in water treed XLPE cable
insulation (1): The influence of geometrical configuration of water
electrode for accelerated water treeing test", J. of Polymer Testing, Vol.
26, 2007, pp. 482 - 488.
[11] P. Pao - la -or, "A New Design of Low Vibration Induction Motor using
Finite Element Method", Doctoral Thesis, Suranaree University of
Technology, Nakhon Ratchasima, Thailand, 2006.