Abstract: In the operation of power transformers of 110 kV/MV from substations, these are traveled by fault current resulting from MV line damage. Defect electrical contacts are heated when they are travelled from fault currents. In the case of high temperatures when 135 °C is reached, the electrical insulating oil in the vicinity of the electrical faults comes into contact with these contacts releases gases, and activates the electrical protection. To avoid auto-flammability of electro-insulating oil, we designed a security system thermal of electrical contact defects by pouring fire-resistant polyurethane foam, mastic or mortar fire inside a cardboard electro-insulating cylinder. From practical experience, in the exploitation of power transformers of 110 kV/MT in oil electro-insulating were recorded some passing disconnecting commanded by the gas protection at internal defects. In normal operation and in the optimal load, nominal currents do not require thermal secure contacts inside electrical transformers, contacts are made at the fabrication according to the projects or to repair by solder. In the case of external short circuits close to the substation, the contacts inside electrical transformers, even if they are well made in sizes of Rcontact = 10‑6 Ω, are subjected to short-circuit currents of the order of 10 kA-20 kA which lead to the dissipation of some significant second-order electric powers, 100 W-400 W, on contact. At some internal or external factors which action on electrical contacts, including electrodynamic efforts at short-circuits, these factors could be degraded over time to values in the range of 10-4 Ω to 10-5 Ω and if the action time of protection is great, on the order of seconds, power dissipation on electrical contacts achieve high values of 1,0 kW to 40,0 kW. This power leads to strong local heating, hundreds of degrees Celsius and can initiate self-ignition and burning oil in the vicinity of electro-insulating contacts with action the gas relay. Degradation of electrical contacts inside power transformers may not be limited for the duration of their operation. In order to avoid oil burn with gas release near electrical contacts, at short-circuit currents 10 kA-20 kA, we have outlined the following solutions: covering electrical contacts in fireproof materials that would avoid direct burn oil at short circuit and transmission of heat from electrical contact along the conductors with heat dissipation gradually over time, in a large volume of cooling. Flame retardant materials are: polyurethane foam, mastic, cement (concrete). In the normal condition of operation of transformer, insulating of conductors coils is with paper and insulating oil. Ignition points of its two components respectively are approximated: 135 °C heat for oil and 200 0C for paper. In the case of a faulty electrical contact, about 10-3 Ω, at short-circuit; the temperature can reach for a short time, a value of 300 °C-400 °C, which ignite the paper and also the oil. By burning oil, there are local gases that disconnect the power transformer. Securing thermal electrical contacts inside the transformer, in cardboard tube with polyurethane foams, mastik or cement, ensures avoiding gas release and also gas protection working.
Abstract: Power transformer is a vital element in a power system as it continuously regulates power flow, maintaining good voltage regulation. The working of transformer much depends on the oil insulation, the oil insulation also decides the aging of transformer and hence its reliability. The mineral oil based liquid insulation is globally accepted for power transformer insulation; however it is potentially hazardous due to its non-biodegradability. In this work efficient alternative biodegradable insulating fluid is presented as a replacement to conventional mineral oil. Dielectric tests are performed as distinct alternating fluid to evaluate the suitability for transformer insulation. The selection of the distinct natural esters for an insulation system is carried out by the laboratory investigation of Breakdown voltage, Oxidation stability, Dissipation factor, Permittivity, Viscosity, Flash and Fire point. It is proposed to study and characterize the properties of natural esters to be used in power transformer. Therefore for the investigation of the dielectric behavior rice bran oil, sesame oil, and sunflower oil are considered for the study. The investigated results have been compared with the mineral oil to validate the dielectric behavior of natural esters.
Abstract: Power transformers are the most crucial part of power electrical system, distribution and transmission grid. This part is maintained using predictive or condition-based maintenance approach. The diagnosis of power transformer condition is performed based on Dissolved Gas Analysis (DGA). There are five main methods utilized for analyzing these gases. These methods are International Electrotechnical Commission (IEC) gas ratio, Key Gas, Roger gas ratio, Doernenburg, and Duval Triangle. Moreover, due to the importance of the transformers, there is a need for an accurate technique to diagnose and hence predict the transformer condition. The main objective of this technique is to avoid the transformer faults and hence to maintain the power electrical system, distribution and transmission grid. In this paper, the DGA was utilized based on the data collected from the transformer records available in the General Electricity Company of Libya (GECOL) which is located in Benghazi-Libya. The Fuzzy Logic (FL) technique was implemented as a diagnostic approach based on IEC gas ratio method. The FL technique gave better results and approved to be used as an accurate prediction technique for power transformer faults. Also, this technique is approved to be a quite interesting for the readers and the concern researchers in the area of FL mathematics and power transformer.
Abstract: In this paper, the equivalent circuit of the ideal single-phase power transformer with its appropriate voltage current measurement was presented. The calculated values of the voltages and currents of the different connections single phase normal transformer and the results of the simulation process are compared. As it can be seen, the calculated results are the same as the simulated results. This paper includes eight possible different transformer connections. Depending on the desired voltage level, step-down and step-up application transformer is considered. Modelling and analysis of a system consisting of an equivalent source, transformer (primary and secondary), and loads are performed to investigate the combinations. The obtained values are simulated in PSpice environment and then how the currents, voltages and phase angle are distributed between them is explained based on calculation.
Abstract: There is a great problem in testing and investigations the reliability of different type of transformers insulation materials. It summarized in how to create and simulate the real conditions of working transformer and testing its insulation materials for Partial Discharge PD, typically as in the working mode. A lot of tests may give untrue results as the physical behavior of the insulation material differs under tests from its working condition. In this work, the real working conditions were simulated, and a large number of specimens have been tested. The investigations first stage, begin with choosing samples of different types of insulation materials (papers, pressboards, etc.). The second stage, the samples were dried in ovens at 105 C0and 0.01bar for 48 hours, and then impregnated with dried and gasless oil (the water content less than 6 ppm.) at 105 C0and 0.01bar for 48 hours, after so specimen cooling at room pressure and temperature for 24 hours. The third stage is investigating PD for the samples using ICM PD measuring device. After that, a continuous test on oil-impregnated insulation materials (paper, pressboards) was developed, and the phase resolved partial discharge pattern of PD signals was measured. The important of this work in providing the industrial sector with trusted high accurate measuring results based on real simulated working conditions. All the PD patterns (results) associated with a discharge produced in well-controlled laboratory condition. They compared with other previous and other laboratory results. In addition, the influence of different temperatures condition on the partial discharge activities was studied.
Abstract: In the standards of IEC 60076-2 and IEC 60076-7, three different hot-spot temperature estimation methods are suggested. In this study, the algorithms which used in hot-spot temperature calculations are analyzed by comparing the algorithms with the results of an experimental set-up made by a Transformer Monitoring System (TMS) in use. In tested system, TMS uses only top oil temperature and load ratio for hot-spot temperature calculation. And also, it uses some constants from standards which are on agreed statements tables. During the tests, it came out that hot-spot temperature calculation method is just making a simple calculation and not uses significant all other variables that could affect the hot-spot temperature.
Abstract: Voltage level must be raised in order to deliver the
produced energy to the consumption zones with less loss and less
cost. Power transformers used to raise or lower voltage are important
parts of the energy transmission system. Power transformers used in
switchgear and power generation plants stay in human's intensive
habitat zones as a result of expanding cities. Accordingly, noise
levels produced by power transformers have begun more and more
important and they have established itself as one of the research field.
In this research, the noise cause on transformers has been
investigated, it's causes has been examined and noise measurement
techniques have been introduced. Examples of transformer noise test
results are submitted and precautions to be taken were discussed for
the purpose of decreasing of the noise which will occurred by
transformers.
Abstract: In insulation and cooling of power transformers
various liquids are used. Mineral oils have wide availability and low
cost. However, they have a poor biodegradability potential and lower
fire point in comparison with other insulating liquids. Use of a liquid
having high biodegradability is important due to environmental
consideration. This paper investigates edible corn oil as an alternative
to mineral oil. Various properties of mineral and corn oil like
breakdown voltage, dissipation factor, relative dielectric constant,
power loss and resistivity were measured according to different
standards.
Abstract: Dissolved gas analysis has been accepted as a sensitive, informative and reliable technique for incipient faults detection in power transformers and is widely used. In the last few years this method, which has been recommended by IEEE Power & Energy society, has been applied for fault detection in load tap changers. Regarding the critical role of load tap changers in electrical network and essential of catastrophic failures prevention, it is necessary to choose "condition based preventative maintenance strategy" which leads to reduction in costs, the number of unnecessary visits as well as the probability of interruptions and also increment in equipment reliability. In current work, considering the condition based preventative maintenance strategy, condition assessment of an Elin tap changer was carried out using dissolved gas analysis.
Abstract: Power transformers are among the most important and
expensive equipments in the electric power systems. Consequently
the transformer protection is an essential part of the system
protection. This paper presents a new method for locating
transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer
body, turn-to-earth, and high voltage winding to low
voltage winding. In this study the current and voltage signals of input
and output terminals of the transformer are measured, which the
Fourier transform of measured signals and harmonic analysis
determine the fault's location.
Abstract: Diagnostic goal of transformers in service is to detect the winding or the core in fault. Transformers are valuable equipment which makes a major contribution to the supply security of a power system. Consequently, it is of great importance to minimize the frequency and duration of unwanted outages of power transformers. So, Frequency Response Analysis (FRA) is found to be a useful tool for reliable detection of incipient mechanical fault in a transformer, by finding winding or core defects. The authors propose as first part of this article, the coupled circuits method, because, it gives most possible exhaustive modelling of transformers. And as second part of this work, the application of FRA in low frequency in order to improve and simplify the response reading. This study can be useful as a base data for the other transformers of the same categories intended for distribution grid.
Abstract: This paper describes interconnection between
technical and economical making decision. The reason of this dealing
could be different: poor technical condition, change of substation
(electrical network) regime, power transformer owner budget deficit
and increasing of tariff on electricity. Establishing of recommended
practice as well as to give general advice and guidance in economical
sector, testing, diagnostic power transformers to establish its
conditions, identify problems and provide potential remedies.
Abstract: Bond graph models of an electrical transformer including
the nonlinear saturation are presented. The transformer
using electrical and magnetic circuits are modelled. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two windings using the properties of a bond graph. The
equivalence between electrical and magnetic variables is given.
The modelling and analysis using this methodology to three phase
power transformers can be extended.
Abstract: Bond graph models of an electrical transformer
including the nonlinear saturation are presented. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two and three windings using the properties of a bond
graph. The modelling and analysis using this methodology to
three phase power transformers or transformers with internal
incipient faults can be extended.
Abstract: In this paper, multilayered coreless printed circuit
board (PCB) step-down power transformers for DC-DC converter
applications have been designed, manufactured and evaluated. A set
of two different circular spiral step-down transformers were
fabricated in the four layered PCB. These transformers have been
modelled with the assistance of high frequency equivalent circuit and
characterized with both sinusoidal and square wave excitation. This
paper provides the comparative results of these two different
transformers in terms of their resistances, self, leakage, mutual
inductances, coupling coefficient and also their energy efficiencies.
The operating regions for optimal performance of these transformers
for power transfer applications are determined. These transformers
were tested for the output power levels of about 30 Watts within the
input voltage range of 12-50 Vrms. The energy efficiency for these
step down transformers is observed to be in the range of 90%-97% in
MHz frequency region.
Abstract: Since large power transformers are the most
expensive and strategically important components of any power
generator and transmission system, their reliability is crucially
important for the energy system operation. Also, Circuit breakers are
very important elements in the power transmission line so monitoring
the events gives a knowledgebase to determine time to the next
maintenance. This paper deals with the introduction of the
comparative method of the state estimation of transformers and
Circuit breakers using continuous monitoring of voltage, current.
This paper gives details a new method based on wavelet to apparatus
insulation monitoring. In this paper to insulation monitoring of
transformer, a new method based on wavelet transformation and
neutral point analysis is proposed. Using the EMTP tools, fault in
transformer winding and the detailed transformer winding model
were simulated. The current of neutral point of winding was analyzed
by wavelet transformation. It is shown that the neutral current of the
transformer winding has useful information about fault in insulation
of the transformer.
Abstract: Economically transformers constitute one of the largest investments in a Power system. For this reason, transformer condition assessment and management is a high priority task. If a transformer fails, it would have a significant negative impact on revenue and service reliability. Monitoring the state of health of power transformers has traditionally been carried out using laboratory Dissolved Gas Analysis (DGA) tests performed at periodic intervals on the oil sample, collected from the transformers. DGA of transformer oil is the single best indicator of a transformer-s overall condition and is a universal practice today, which started somewhere in the 1960s. Failure can occur in a transformer due to different reasons. Some failures can be limited or prevented by maintenance. Oil filtration is one of the methods to remove the dissolve gases and prevent the deterioration of the oil. In this paper we analysis the DGA data by regression method and predict the gas concentration in the oil in the future. We bring about a comparative study of different traditional methods of regression and the errors generated out of their predictions. With the help of these data we can deduce the health of the transformer by finding the type of fault if it has occurred or will occur in future. Additional in this paper effect of filtration on the transformer health is highlight by calculating the probability of failure of a transformer with and without oil filtrating.
Abstract: The most important parameter in transformers life
expectancy is the hot-spot temperature level which accelerates the
rate of aging of the insulation. The aim of this paper is to present
thermal models for transformers loaded at prefabricated MV/LV
transformer substations and outdoor situations. The hot-spot
temperature of transformers is studied using their top-oil temperature
rise models. The thermal models proposed for hot-spot and top-oil
temperatures of different operating situations are compared. Since the
thermal transfer is different for indoor and outdoor transformers
considering their operating conditions, their hot-spot thermal models
differ from each other. The proposed thermal models are verified by
the results obtained from the experiments carried out on a typical
1600 kVA, 30 /0.4 kV, ONAN transformer for both indoor and
outdoor situations.