Abstract: In this study, the performance of a high-frequency arc
welding machine including a two-switch inverter is analyzed. The
control of the system is achieved using two different control
techniques i- fuzzy logic control (FLC) ii- state space averaging
based sliding control. Fuzzy logic control does not need accurate
mathematical model of a plant and can be used in nonlinear
applications. The second method needs the mathematical model of
the system. In this method the state space equations of the system are
derived for two different “on" and “off" states of the switches. The
derived state equations are combined with the sliding control rule
considering the duty-cycle of the converter. The performance of the
system is analyzed by simulating the system using SIMULINK tool
box of MATLAB. The simulation results show that fuzzy logic
controller is more robust and less sensitive to parameter variations.
Abstract: The most important parameter in transformers life
expectancy is the hot-spot temperature level which accelerates the
rate of aging of the insulation. The aim of this paper is to present
thermal models for transformers loaded at prefabricated MV/LV
transformer substations and outdoor situations. The hot-spot
temperature of transformers is studied using their top-oil temperature
rise models. The thermal models proposed for hot-spot and top-oil
temperatures of different operating situations are compared. Since the
thermal transfer is different for indoor and outdoor transformers
considering their operating conditions, their hot-spot thermal models
differ from each other. The proposed thermal models are verified by
the results obtained from the experiments carried out on a typical
1600 kVA, 30 /0.4 kV, ONAN transformer for both indoor and
outdoor situations.