Abstract: The IEEE 802.22 working group aims to drive the
Digital Video Broadcasting-Terrestrial (DVB-T) bands for data
communication to the rural area without interfering the TV broadcast.
In this paper, we arrive at a closed-form expression for average
detection probability of Fusion center (FC) with multiple antenna
over the κ − μ fading channel model. We consider a centralized
cooperative multiple antenna network for reporting. The DVB-T
samples forwarded by the secondary user (SU) were combined using
Maximum ratio combiner at FC, an energy detection is performed
to make the decision. The fading effects of the channel degrades
the detection probability of the FC, a generalized independent and
identically distributed (IID) κ − μ and an additive white Gaussian
noise (AWGN) channel is considered for reporting and sensing
respectively. The proposed system performance is verified through
simulation results.
Abstract: At present, the evaluation of voltage stability
assessment experiences sizeable anxiety in the safe operation of
power systems. This is due to the complications of a strain power
system. With the snowballing of power demand by the consumers
and also the restricted amount of power sources, therefore, the system
has to perform at its maximum proficiency. Consequently, the
noteworthy to discover the maximum ability boundary prior to
voltage collapse should be undertaken. A preliminary warning can be
perceived to evade the interruption of power system’s capacity. The
effectiveness of line voltage stability indices (LVSI) is differentiated
in this paper. The main purpose of the indices used is to predict the
proximity of voltage instability of the electric power system. On the
other hand, the indices are also able to decide the weakest load buses
which are close to voltage collapse in the power system. The line
stability indices are assessed using the IEEE 14 bus test system to
validate its practicability. Results demonstrated that the implemented
indices are practically relevant in predicting the manifestation of
voltage collapse in the system. Therefore, essential actions can be
taken to dodge the incident from arising.
Abstract: This paper reports a structured literature review of the
application of Health Information Technology in developing
countries, defined as the World Bank categories Low-income
countries, Lower-middle-income, and Upper-middle-income
countries. The aim was to identify and classify the various
applications of health information technology to assess its current
state in developing countries and explore potential areas of research.
We offer specific analysis and application of HIT in Libya as one of
the developing countries. A structured literature review was
conducted using the following online databases: IEEE, Science
Direct, PubMed, and Google Scholar. Publication dates were set for
2000-2013. For the PubMed search, publications in English, French,
and Arabic were specified. Using a content analysis approach, 159
papers were analyzed and a total number of 26 factors were identified
that affect the adoption of health information technology. Of the 2681
retrieved articles, 159 met the inclusion criteria which were carefully
analyzed and classified. The implementation of health information
technology across developing countries is varied. Whilst it was
initially expected financial constraints would have severely limited
health information technology implementation, some developing
countries like India have nevertheless dominated the literature and
taken the lead in conducting scientific research. Comparing the
number of studies to the number of countries in each category, we
found that Low-income countries and Lower-middle-income had
more studies carried out than Upper-middle-income countries.
However, whilst IT has been used in various sectors of the economy,
the healthcare sector in developing countries is still failing to benefit
fully from the potential advantages that IT can offer.
Abstract: This paper proposes a backward/forward sweep
method to analyze the power flow in radial distribution systems. The
distribution system has radial structure and high R/X ratios. So the
newton-raphson and fast decoupled methods are failed with
distribution system. The proposed method presents a load flow study
using backward/forward sweep method, which is one of the most
effective methods for the load-flow analysis of the radial distribution
system. By using this method, power losses for each bus branch and
voltage magnitudes for each bus node are determined. This method
has been tested on IEEE 33-bus radial distribution system and
effective results are obtained using MATLAB.
Abstract: In this paper an isolated wind-diesel hybrid power
system has been considered for reactive power control study having
an induction generator for wind power conversion and synchronous
alternator with automatic voltage regulator (AVR) for diesel unit is
presented. The dynamic voltage stability evaluation is dependent on
small signal analysis considering a Static VAR Compensator (SVC)
and IEEE type -I excitation system. It's shown that the variable
reactive power source like SVC is crucial to meet the varying
demand of reactive power by induction generator and load and to
acquire an excellent voltage regulation of the system with minimum
fluctuations. Integral square error (ISE) criterion can be used to
evaluate the optimum setting of gain parameters. Finally the dynamic
responses of the power systems considered with optimum gain setting
will also be presented.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.
Abstract: This paper considers the characterization of a complex
electromagnetic environment due to multiple sources of
electromagnetic radiation as a five-dimensional surface which can be
described by a set of several surface sections including: instant EM
field intensity distribution maps at a given frequency and altitude,
instantaneous spectrum at a given location in space and the time
evolution of the electromagnetic field spectrum at a given point in
space. This characterization if done over time can enable the
exposure levels of Radio Frequency Radiation at every point in the
analysis area to be determined and results interpreted based on
comparison of the determined RFR exposure level with the safe
guidelines for general public exposure given by recognized body
such as the International commission on non-ionizing radiation
protection (ICNIRP), Institute of Electrical and Electronic Engineers
(IEEE), the National Radiation Protection Authority (NRPA).
Abstract: WiMAX is a telecommunications technology and it is
specified by the Institute of Electrical and Electronics Engineers Inc.,
as the IEEE 802.16 standard. The goal of this technology is to
provide a wireless data over long distances in a variety of ways. IEEE
802.16 is a recent standard for mobile communication. In this paper,
we provide an overview of various key management algorithms to
provide security for WiMAX.
Abstract: This paper aims at finding a suitable neural network
for monitoring congestion level in electrical power systems. In this
paper, the input data has been framed properly to meet the target
objective through supervised learning mechanism by defining normal
and abnormal operating conditions for the system under study. The
congestion level, expressed as line congestion index (LCI), is
evaluated for each operating condition and is presented to the NN
along with the bus voltages to represent the input and target data.
Once, the training goes successful, the NN learns how to deal with a
set of newly presented data through validation and testing
mechanism. The crux of the results presented in this paper rests on
performance comparison of a multi-layered feed forward neural
network with eleven types of back propagation techniques so as to
evolve the best training criteria. The proposed methodology has been
tested on the standard IEEE-14 bus test system with the support of
MATLAB based NN toolbox. The results presented in this paper
signify that the Levenberg-Marquardt backpropagation algorithm
gives best training performance of all the eleven cases considered in
this paper, thus validating the proposed methodology.
Abstract: This paper presents the voltage problem location
classification using performance of Least Squares Support Vector
Machine (LS-SVM) and Learning Vector Quantization (LVQ) in
electrical power system for proper voltage problem location
implemented by IEEE 39 bus New- England. The data was collected
from the time domain simulation by using Power System Analysis
Toolbox (PSAT). Outputs from simulation data such as voltage, phase
angle, real power and reactive power were taken as input to estimate
voltage stability at particular buses based on Power Transfer Stability
Index (PTSI).The simulation data was carried out on the IEEE 39 bus
test system by considering load bus increased on the system. To verify
of the proposed LS-SVM its performance was compared to Learning
Vector Quantization (LVQ). The results showed that LS-SVM is faster
and better as compared to LVQ. The results also demonstrated that the
LS-SVM was estimated by 0% misclassification whereas LVQ had
7.69% misclassification.
Abstract: Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been developed and incorporated in the SVS control system located at the middle of the series compensated long transmission line. Damping of torsional stresses due to subsynchronous resonance resulting from series capacitive compensation using CBVLC is investigated in this paper. Simulation results are carried out with MATLAB/Simulink on the IEEE first benchmark model (FBM). The simulation results show that the oscillations are satisfactorily damped out by the SVS supplementary controller. Time domain simulation is performed on power system and the results demonstrate the effectiveness of the proposed controller.
Abstract: This paper investigates the effect of simultaneous placement of DGs and smart meters (SMs), on voltage profile improvement in active distribution networks (ADNs). A substantial center of attention has recently been on responsive loads initiated in power system problem studies such as distributed generations (DGs). Existence of responsive loads in active distribution networks (ADNs) would have undeniable effect on sizing and siting of DGs. For this reason, an optimal framework is proposed for sizing and siting of DGs and SMs in ADNs. SMs are taken into consideration for the sake of successful implementing of demand response programs (DRPs) such as direct load control (DLC) with end-side consumers. Looking for voltage profile improvement, the optimization procedure is solved by genetic algorithm (GA) and tested on IEEE 33-bus distribution test system. Different scenarios with variations in the number of DG units, individual or simultaneous placing of DGs and SMs, and adaptive power factor (APF) mode for DGs to support reactive power have been established. The obtained results confirm the significant effect of DRPs and APF mode in determining the optimal size and site of DGs to be connected in ADN resulting to the improvement of voltage profile as well.
Abstract: This paper presents an intensive measurement studying of the network performance analysis when IEEE 802.11g Wireless Local Area Networks (WLAN) coexisting with IEEE 802.15.4 Wireless Personal Area Network (WPAN). The measurement results show that the coexistence between both networks could increase the Frame Error Rate (FER) of the IEEE 802.15.4 networks up to 60% and it could decrease the throughputs of the IEEE 802.11g networks up to 55%.
Abstract: Indoor wireless localization systems have played an
important role to enhance context-aware services. Determining the
position of mobile objects in complex indoor environments, such as
those in multi-floor buildings, is very challenging problems. This
paper presents an effective floor estimation algorithm, which can
accurately determine the floor where mobile objects located. The
proposed algorithm is based on the confidence interval of the
summation of online Received Signal Strength (RSS) obtained from
the IEEE 802.15.4 Wireless Sensor Networks (WSN).We compare
the performance of the proposed algorithm with those of other floor
estimation algorithms in literature by conducting a real
implementation of WSN in our facility. The experimental results and
analysis showed that the proposed floor estimation algorithm
outperformed the other algorithms and provided highest percentage
of floor accuracy up to 100% with 95-percent confidence interval.
Abstract: The advent of Flexible AC Transmission Systems (FACTS) is giving rise to a new family of power electronic equipment emerging for controlling and optimizing the performance of power system, e.g. STATCOM. Static synchronous Compensator (STATCOM) is a commonly used FACTS device and has been successfully applied in power systems. In this sense, superconducting magnetic energy storage (SMES) in integration with a static synchronous compensator (STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper the structure and characteristics of the STATCOM/SMES is proposed. In addition, using a proper control scheme, STATCOM/ SMES is tested on an IEEE 3-bus system and more effective performance of the presented STATCOM/SMES compensator is evaluated with alone STATCOM through the dynamic simulation by using PSCAD/EMTDC software.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: One of the most essential issues in software products is to maintain it relevancy to the dynamics of the user’s requirements and expectation. Many studies have been carried out in quality aspect of software products to overcome these problems. Previous software quality assessment models and metrics have been introduced with strengths and limitations. In order to enhance the assurance and buoyancy of the software products, certification models have been introduced and developed. From our previous experiences in certification exercises and case studies collaborating with several agencies in Malaysia, the requirements for user based software certification approach is identified and demanded. The emergence of social network applications, the new development approach such as agile method and other varieties of software in the market have led to the domination of users over the software. As software become more accessible to the public through internet applications, users are becoming more critical in the quality of the services provided by the software. There are several categories of users in web-based systems with different interests and perspectives. The classifications and metrics are identified through brain storming approach with includes researchers, users and experts in this area. The new paradigm in software quality assessment is the main focus in our research. This paper discusses the classifications of users in web-based software system assessment and their associated factors and metrics for quality measurement. The quality model is derived based on IEEE structure and FCM model. The developments are beneficial and valuable to overcome the constraints and improve the application of software certification model in future.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. The distribution feeder reconfiguration (DFR) is one of the most important control schemes in the distribution networks, which can be affected by DGs. This paper presents a new approach to DFR at the distribution networks considering wind turbines. The main objective of the DFR is to minimize the deviation of the bus voltage. Since the DFR is a nonlinear optimization problem, we apply the Adaptive Modified Firefly Optimization (AMFO) approach to solve it. As a result of the conflicting behavior of the single- objective function, a fuzzy based clustering technique is employed to reach the set of optimal solutions called Pareto solutions. The approach is tested on the IEEE 32-bus standard test system.
Abstract: In this paper, the design of a coaxial feed single layer rectangular microstrip patch antenna for IEEE802.11b application is presented. The proposed antenna is designed by using substrate FR4_epoxy having permittivity of about 4.4 and tangent loss of 0.013. The characteristics of the substrate are designed and to evaluate the performance of modeled antenna using HFSS v.11 EM simulator, from Ansoft. The proposed antenna dual resonant frequency has been achieved in the band of 1.57GHz-1.68GHz (with BW 30 MHz) and 2.25 GHz -2.55GHz (with BW 40MHz). The simulation results with frequency response, radiation pattern and return loss, VSWR, Input Impedance are presented with appropriate table and graph.
Abstract: This paper presents a novel CPW fed patch antenna supporting a wide band from 2.7 GHz – 6.5 GHz. The antenna is compact with size 32 x 30 x 1.6mm3, built over FR4-epoxy substrate (εr=4.4). Bandwidth enhancement has been achieved by using the concept of modified ground structure (MGS). For this purpose structural design has been optimized by parametric simulations in CST MWS. The proposed antenna can perform well in variety of wireless communication services including 5.15 GHz- 5.35 GHz and 5.725 GHz- 5.825 GHz WLAN IEEE 802.11 g/a, 5.2/ 5.5/ 5.8 GHz Wi-Fi, 3.5/5.5 GHz WiMax applications and 3.7 - 4.2 GHz C band satellite communications bands. The measured experimental results show that bandwidth (S11 < -10 dB) of antenna is 3.8 GHz. The performance of antenna is studied in terms of reflection coefficient, radiation characteristics, current distribution and gain.