Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: In this paper, we propose a new method for threedimensional
object indexing based on D.A.M.C-S.H.C descriptor
(Direct and Analytical Method for Calculating the Spherical
Harmonics Coefficients). For this end, we propose a direct
calculation of the coefficients of spherical harmonics with perfect
precision. The aims of the method are to minimize, the processing
time on the 3D objects database and the searching time of similar
objects to a request object.
Firstly we start by defining the new descriptor using a new
division of 3-D object in a sphere. Then we define a new distance
which will be tested and prove his efficiency in the search for similar
objects in the database in which we have objects with very various
and important size.
Abstract: This paper proposed the comparison made between
Multi-Carrier Pulse Width Modulation, Sinusoidal Pulse Width
Modulation and Selective Harmonic Elimination Pulse Width
Modulation technique for minimization of Total Harmonic Distortion
in Cascaded H-Bridge Multi-Level Inverter. In Multicarrier Pulse
Width Modulation method by using Alternate Position of Disposition
scheme for switching pulse generation to Multi-Level Inverter.
Another carrier based approach; Sinusoidal Pulse Width Modulation
method is also implemented to define the switching pulse generation
system in the multi-level inverter. In Selective Harmonic Elimination
method using Genetic Algorithm and Particle Swarm Optimization
algorithm for define the required switching angles to eliminate low
order harmonics from the inverter output voltage waveform and
reduce the total harmonic distortion value. So, the results validate that
the Selective Harmonic Elimination Pulse Width Modulation method
does capably eliminate a great number of precise harmonics and
minimize the Total Harmonic Distortion value in output voltage
waveform in compared with Multi-Carrier Pulse Width Modulation
method, Sinusoidal Pulse Width Modulation method. In this paper,
comparison of simulation results shows that the Selective Harmonic
Elimination method can attain optimal harmonic minimization
solution better than Multi-Carrier Pulse Width Modulation method,
Sinusoidal Pulse Width Modulation method.
Abstract: This article proposes a new method for application in
communication circuit systems that increase efficiency, PAE, output
power and gain in the circuit. The proposed method is based on a
combination of switching class-E and class-J and has been termed
class-EJ. This method was investigated using both theory and
simulation to confirm ∼72% PAE and output power of >39dBm. The
combination and design of the proposed power amplifier accrues gain
of over 15dB in the 2.9 to 3.5GHz frequency bandwidth. This circuit
was designed using MOSFET and high power transistors. The loadand
source-pull method achieved the best input and output networks
using lumped elements. The proposed technique was investigated for
fundamental and second harmonics having desirable amplitudes for
the output signal.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: This article presents two methods for the
compensation of harmonics generated by a nonlinear load. The first is
the classic method P-Q. The second is the controller by modern
method of artificial intelligence specifically fuzzy logic. Both
methods are applied to a shunt Active Power Filter (sAPF) based on a
three-phase voltage converter at five levels NPC topology. In
calculating the harmonic currents of reference, we use the algorithm
P-Q and pulse generation, we use the intersective PWM. For
flexibility and dynamics, we use fuzzy logic. The results give us clear
that the rate of Harmonic Distortion issued by fuzzy logic is better
than P-Q.
Abstract: ESPRIT-TLS method appears a good choice for high
resolution fault detection in induction machines. It has a very high
effectiveness in the frequency and amplitude identification.
Contrariwise, it presents a high computation complexity which
affects its implementation in real time fault diagnosis. To avoid this
problem, a Fast-ESPRIT algorithm that combined the IIR band-pass
filtering technique, the decimation technique and the original
ESPRIT-TLS method was employed to enhance extracting accurately
frequencies and their magnitudes from the wind stator current with
less computation cost. The proposed algorithm has been applied to
verify the wind turbine machine need in the implementation of an online,
fast, and proactive condition monitoring. This type of remote
and periodic maintenance provides an acceptable machine lifetime,
minimize its downtimes and maximize its productivity. The
developed technique has evaluated by computer simulations under
many fault scenarios. Study results prove the performance of Fast-
ESPRIT offering rapid and high resolution harmonics recognizing
with minimum computation time and less memory cost.
Abstract: In this paper, we propose a method for three-dimensional
(3-D)-model indexing based on defining a new
descriptor, which we call new descriptor using spherical harmonics.
The purpose of the method is to minimize, the processing time on the
database of objects models and the searching time of similar objects
to request object.
Firstly we start by defining the new descriptor using a new
division of 3-D object in a sphere. Then we define a new distance
which will be used in the search for similar objects in the database.
Abstract: The aim of this work is to present a theoretical analysis of a 2D ultrasound transducer comprised of crossed arrays of metal strips placed on both sides of thin piezoelectric layer (a). Such a structure is capable of electronic beam-steering of generated wavebeam both in elevation and azimuth. In this paper a semi-analytical model of the considered transducer is developed. It is based on generalization of the well-known BIS-expansion method. Specifically, applying the electrostatic approximation, the electric field components on the surface of the layer are expanded into fast converging series of double periodic spatial harmonics with corresponding amplitudes represented by the properly chosen Legendre polynomials. The problem is reduced to numerical solving of certain system of linear equations for unknown expansion coefficients.
Abstract: Power quality has become a very important issue recently due to the impact on electricity suppliers, equipment manufacturers and customers. Power quality is described as the variation of voltage, current and frequency in a power system. Voltage magnitude is one of the major factors that determine the quality of power. Indeed, custom power technology, the low-voltage counterpart of the more widely known flexible ac transmission system (FACTS) technology, aimed at high-voltage power transmission applications, has emerged as a credible solution to solve many problems relating to power quality problems. There are various power quality problems such as voltage sags, swells, flickers, interruptions and harmonics etc. Active Power Filter (APF) is one of the custom power devices and can mitigate harmonics, reactive power and unbalanced load currents originating from load side. In this study, an extensive review of APF studies, the advantages and disadvantages of each introduced methods are presented. The study also helps the researchers to choose the optimum control techniques and power circuit configuration for APF applications.
Abstract: In the last few years, harmonics have been occurred
with the increasing use of nonlinear loads, and these harmonics have
been an ever increasing problem for the line systems. This situation
importantly affects the quality of power and gives large losses to the
network. An efficient way to solve these problems is providing
harmonic compensation through parallel active power filters. Many
methods can be used in the control systems of the parallel active
power filters which provide the compensation. These methods
efficiently affect the performance of the active power filters. For this
reason, the chosen control method is significant. In this study, Fourier
analysis (FA) control method and synchronous reference frame (SRF)
control method are discussed. These control methods are designed for
both eliminate harmonics and perform reactive power compensation
in MATLAB/Simulink pack program and are tested. The results have
been compared for each two methods.
Abstract: The increasing penetration of Distributed Generation and storage connected to the distribution network via PWM converters increases the possibility of a DC-component (offset) in voltage or current flowing into the grid. This occurs when even harmonics are present in the network voltage. DC-components can affect the operation and safety of several grid components. Therefore, an investigation of the way they are produced is important in order to take appropriate measures for their elimination. Further research on DC-components that appear on output voltage of converters is performed for different parameters of PWM technique and characteristics of even harmonics.
Abstract: In this work, an experimental technique is applied
for the measurements of the vibrations and deformation of a test
transformer core. Since the grid voltage contains some higher
harmonics, in addition to a purely sinusoidal magnetisation of the
core the presence of third harmonic is also studied. The vibrations of
the transformer core for points as well as the surface scan of the leg
show more deformation in the corners of the leg than the middle of
the leg. The influence of the higher harmonic of the magnetisation
on the core deformation is also more significant in the corners of the
leg. The core deformation shape under a sinusoidal magnetisation
with a higher harmonic is more wavy and fluctuating than that under
a purely sinusoidal magnetisation.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: Multilevel inverters such as flying capacitor, diodeclamped,
and cascaded H-bridge inverters are very popular
particularly in medium and high power applications. This paper
focuses on a cascaded H-bridge module using a single direct current
(DC) source in order to generate an 11-level output voltage. The
noble approach reduces the number of switches and gate drivers, in
comparison with a conventional method. The anticipated topology
produces more accurate result with an isolation transformer at high
switching frequency. Different modulation techniques can be used for
the multilevel inverter, but this work features modulation techniques
known as selective harmonic elimination (SHE).This modulation
approach reduces the number of carriers with reduction in Switching
Losses, Total Harmonic Distortion (THD), and thereby increasing
Power Quality (PQ). Based on the simulation result obtained, it
appears SHE has the ability to eliminate selected harmonics by
chopping off the fundamental output component. The performance
evaluation of the proposed cascaded multilevel inverter is performed
using PSIM simulation package and THD of 0.94% is obtained.
Abstract: One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results.
Abstract: This study is carried out to understand the effects of Static frequency converter (SFC) on large machine. SFC has a feature of four quadrant operations. By virtue of this it can be implemented to run a synchronous machine either as a motor or alternator. This dual mode operation helps a single machine to start & run as a motor and then it can be converted as an alternator whenever required. One such dual purpose machine is taken here for study. This machine is installed at a laboratory carrying out short circuit test on high power electrical equipment. SFC connected with this machine is broadly described in this paper. The same SFC has been modeled with the MATLAB/Simulink software. The data applied on this virtual model are the actual parameters from SFC and synchronous machine. After running the model, simulated machine voltage and current waveforms are validated with the real measurements. Processing of these waveforms is done through Fast Fourier Transformation (FFT) which reveals that the waveforms are not sinusoidal rather they contain number of harmonics. These harmonics are the major cause of generating shaft voltage. It is known that bearings of electrical machine are vulnerable to current flow through it due to shaft voltage. A general discussion on causes of shaft voltage in perspective with this machine is presented in this paper.
Abstract: In this paper, the development of the ephemeris generation module used for the Thaichote satellite operations is presented. It is a vital part of the flight dynamics system, which comprises, the orbit determination, orbit propagation, event prediction and station-keeping maneouvre modules. In the generation of the spacecraft ephemeris data, the estimated orbital state vector from the orbit determination module is used as an initial condition. The equations of motion are then integrated forward in time to predict the satellite states. The higher geopotential harmonics, as well as other disturbing forces, are taken into account to resemble the environment in low-earth orbit. Using a highly accurate numerical integrator based on the Burlish-Stoer algorithm the ephemeris data can be generated for long-term predictions, by using a relatively small computation burden and short calculation time. Some events occurring during the prediction course that are related to the mission operations, such as the satellite’s rise/set viewed from the ground station, Earth and Moon eclipses, the drift in groundtrack as well as the drift in the local solar time of the orbital plane are all detected and reported. When combined with other modules to form a flight dynamics system, this application is aimed to be applied for the Thaichote satellite and successive Thailand’s Earth-observation missions.
Abstract: Power quality is used to describe the degree of consistency of electrical energy expected from generation source to point of use. The term power quality refers to a wide variety of electromagnetic phenomena that characterize the voltage and current at a given time and at a given location on the power system. Power quality problems can be defined as problem that results in failure of customer equipments, which manifests itself as an economic burden to users, or produces negative impacts on the environment. Voltage stability, power factor, harmonics pollution, reactive power and load unbalance are some of the factors that affect the consistency or the quality level. This research proposal proposes to investigate and analyze the causes and effects of power quality to homes and industries in Sarawak. The increasing application of electronics equipment used in the industries and homes has caused a big impact on the power quality. Many electrical devices are now interconnected to the power network and it can be observed that if the power quality of the network is good, then any loads connected to it will run smoothly and efficiently. On the other hand, if the power quality of the network is bad, then loads connected to it will fail or may cause damage to the equipments and reduced its lifetime. The outcome of this research will enable better and novel solutions of poor power quality to small industries and reduce damage of electrical devices and products in the industries.