Abstract: Modern industrial processes are based on a large amount of electronic devices such as programmable logic controllers and adjustable speed drives. Unfortunately, electronic devices are sensitive to disturbances, and thus, industrial loads become less tolerant to power quality problems such as sags, swells, and harmonics. Voltage sags are an important power quality problem. In this paper proposed a new configuration of Static Var Compensator (SVC) considering three different conditions named as topologies and Booster transformer with fuzzy logic based controller, capable of compensating for power quality problems associated with voltage sags and maintaining a prescribed level of voltage profile. Fuzzy logic controller is designed to achieve the firing angles for SVC such that it maintains voltage profile. The online monitoring system for voltage sag mitigation in the laboratory using the hardware is used. The results are presented from the performance of each topology and Booster transformer considered in this paper.
Abstract: This paper is based on the performance of the Switched Reluctance Motor (SRM) drives using Z-Source Inverter with the simplified rule base of Fuzzy Logic Controller (FLC) with the output scaling factor (SF) self-tuning mechanism are proposed. The aim of this paper is to simplify the program complexity of the controller by reducing the number of fuzzy sets of the membership functions (MFs) without losing the system performance and stability via the adjustable controller gain. ZSI exhibits both voltage-buck and voltage-boost capability. It reduces line harmonics, improves reliability, and extends output voltage range. The output SF of the controller can be tuned continuously by a gain updating factor, whose value is derived from fuzzy logic, with the plant error and error change ratio as input variables. Then the results, carried out on a four-phase 6/8 pole SRM based on the dSPACEDS1104 platform, to show the feasibility and effectiveness of the devised methods and also performance of the proposed controllers will be compared with conventional counterpart.
Abstract: Robust stability and performance are the two most
basic features of feedback control systems. The harmonic balance
analysis technique enables to analyze the stability of limit cycles
arising from a neural network control based system operating over
nonlinear plants. In this work a robust stability analysis based on the
harmonic balance is presented and applied to a neural based control
of a non-linear binary distillation column with unstructured
uncertainty. We develop ways to describe uncertainty in the form of
neglected nonlinear dynamics and high harmonics for the plant and
controller respectively. Finally, conclusions about the performance of
the neural control system are discussed using the Nyquist stability
margin together with the structured singular values of the uncertainty
as a robustness measure.
Abstract: This paper presents an effective technique for harmonic current mitigation using an adaptive notch filter (ANF) to estimate current harmonics. The proposed filter consists of multiple units of ANF connected in parallel structure; each unit is governed by two ordinary differential equations. The frequency estimation is carried out based on the output of these units. The simulation and experimental results show the ability of the proposed tracking scheme to accurately estimate harmonics. The proposed filter was implemented digitally in TMS320F2808 and used in the control of hybrid active power filter (HAPF). The theoretical expectations are verified and demonstrated experimentally.
Abstract: A Space Vector based Pulse Width Modulation
control technique for the three-phase PWM converter is proposed in
this paper. The proposed control scheme is based on a synchronous
reference frame model. High performance and efficiency is obtained
with regards to the DC bus voltage and the power factor
considerations of the PWM rectifier thus leading to low losses.
MATLAB/SIMULINK are used as a platform for the simulations and
a SIMULINK model is presented in the paper. The results show that
the proposed model demonstrates better performance and properties
compared to the traditional SPWM method and the method improves
the dynamic performance of the closed loop drastically.
For the Space Vector based Pulse Width Modulation, Sine signal
is the reference waveform and triangle waveform is the carrier
waveform. When the value sine signal is large than triangle signal,
the pulse will start produce to high. And then when the triangular
signals higher than sine signal, the pulse will come to low. SPWM
output will changed by changing the value of the modulation index
and frequency used in this system to produce more pulse width. The
more pulse width produced, the output voltage will have lower
harmonics contents and the resolution increase.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical trainings,
thanks to the adjustable inverters, as the Pulse Wide Modulation
(PWM) five level inverters, which is the object of study in this
article.The authors treat the relation between the law order adopted for
a given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment).
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: Application of neural networks in execution of
programmed pulse width modulation (PPWM) of a voltage source
inverter (VSI) is studied in this paper. Using the proposed method it is
possible to cancel out the desired harmonics in output of VSI in
addition to control the magnitude of fundamental harmonic,
contineously. By checking the non-trained values and a performance
index, the most appropriate neural network is proposed. It is shown
that neural networks may solve the custom difficulties of practical
utilization of PPWM such as large size of memory, complex digital
circuits and controlling the magnitude of output voltage in a discrete
manner.
Abstract: In this paper, we analyze the rotor eddy currents losses provoqued by the stator slot harmonics developed in the permanent magnets or pole pieces of synchronous machines. An analytical approach is presented to evaluate the effect of slot ripples on rotor field and losses calculation. This analysis is then tested on a model by 2D/3D finite element (FE) calculation. The results show a good agreement on loss calculations when skin effect is negligible and the magnet is considered.
Abstract: The perfect operation of common Active Filters is depended on accuracy of identification system distortion. Also, using a suitable method in current injection and reactive power compensation, leads to increased filter performance. Due to this fact, this paper presents a method based on predictive current control theory in shunt active filter applications. The harmonics of the load current is identified by using o–d–q reference frame on load current and eliminating the DC part of d–q components. Then, the rest of these components deliver to predictive current controller as a Threephase reference current by using Park inverse transformation. System is modeled in discreet time domain. The proposed method has been tested using MATLAB model for a nonlinear load (with Total Harmonic Distortion=20%). The simulation results indicate that the proposed filter leads to flowing a sinusoidal current (THD=0.15%) through the source. In addition, the results show that the filter tracks the reference current accurately.
Abstract: This paper describes a new method for extracting the fetal heart rate (fHR) and the fetal heart rate variability (fHRV) signal non-invasively using abdominal maternal electrocardiogram (mECG) recordings. The extraction is based on the fundamental frequency (Fourier-s) theorem. The fundamental frequency of the mother-s electrocardiogram signal (fo-m) is calculated directly from the abdominal signal. The heart rate of the fetus is usually higher than that of the mother; as a result, the fundamental frequency of the fetal-s electrocardiogram signal (fo-f) is higher than that of the mother-s (fo-f > fo-m). Notch filters to suppress mother-s higher harmonics were designed; then a bandpass filter to target fo-f and reject fo-m is implemented. Although the bandpass filter will pass some other frequencies (harmonics), we have shown in this study that those harmonics are actually carried on fo-f, and thus have no impact on the evaluation of the beat-to-beat changes (RR intervals). The oscillations of the time-domain extracted signal represent the RR intervals. We have also shown in this study that zero-to-zero evaluation of the periods is more accurate than the peak-to-peak evaluation. This method is evaluated both on simulated signals and on different abdominal recordings obtained at different gestational ages.
Abstract: A new topology of unified power quality conditioner
(UPQC) is proposed for different power quality (PQ) improvement in
a three-phase four-wire (3P-4W) distribution system. For neutral
current mitigation, a star-hexagon transformer is connected in shunt
near the load along with three-leg voltage source inverters (VSIs)
based UPQC. For the mitigation of source neutral current, the uses of
passive elements are advantageous over the active compensation due
to ruggedness and less complexity of control. In addition to this, by
connecting a star-hexagon transformer for neutral current mitigation
the over all rating of the UPQC is reduced. The performance of the
proposed topology of 3P-4W UPQC is evaluated for power-factor
correction, load balancing, neutral current mitigation and mitigation
of voltage and currents harmonics. A simple control algorithm based
on Unit Vector Template (UVT) technique is used as a control
strategy of UPQC for mitigation of different PQ problems. In this
control scheme, the current/voltage control is applied over the
fundamental supply currents/voltages instead of fast changing APFs
currents/voltages, thereby reducing the computational delay.
Moreover, no extra control is required for neutral source current
compensation; hence the numbers of current sensors are reduced. The
performance of the proposed topology of UPQC is analyzed through
simulations results using MATLAB software with its Simulink and
Power System Block set toolboxes.
Abstract: This paper proposes a new optimal feedback controller
for voltage source converters VSC's, for current regulated voltage
source converters, which allows compensate the harmonics of current
produced by nonlinear loads and load reactive power. The aim of the
present paper is to describe a novel switching signal generation
technique called optimal controller which guarantees that the injected
currents follow the reference currents determined by the
compensation strategy, with the smallest possible tracking error and
fixed switching frequency. It is compared with well-known
hysteresis current controller HCC. The validity of presented method
and its comparison with HCC is studied through simulation results.
Abstract: Rolling element bearings are widely used in industry,
especially where high load capacity is required. The diagnosis of
their conditions is essential matter for downtime reduction and saving
cost of maintenance. Therefore, an intensive analysis of frequency
spectrum of their faults must be carried out in order to determine the
main reason of the fault. This paper focus on a beating phenomena
observed in the waveform (time domain) of a cylindrical rolling
element bearing. The beating frequencies were not related to any
sources nearby the machine nor any other malfunctions (unbalance,
misalignment ...etc). More investigation on the spike energy and the
frequency spectrum indicated a problem with races of the bearing.
Multi-harmonics of the fundamental defects frequencies were
observed. Two of them were close to each other in magnitude those
were the source of the beating phenomena.
Abstract: This paper proposes fractal patterns for power quality
(PQ) detection using color relational analysis (CRA) based classifier.
Iterated function system (IFS) uses the non-linear interpolation in the
map and uses similarity maps to construct various fractal patterns of
power quality disturbances, including harmonics, voltage sag, voltage
swell, voltage sag involving harmonics, voltage swell involving
harmonics, and voltage interruption. The non-linear interpolation
functions (NIFs) with fractal dimension (FD) make fractal patterns
more distinguishing between normal and abnormal voltage signals.
The classifier based on CRA discriminates the disturbance events in a
power system. Compared with the wavelet neural networks, the test
results will show accurate discrimination, good robustness, and faster
processing time for detecting disturbing events.
Abstract: This paper proposes different methods for estimation
of the harmonic currents of the single-phase diode bridge rectifier. Both simple and advanced methods are compared and the models are
put into a context of practical use for calculating the harmonic distortion in a typical application. Finally, the different models are
compared to measurements of a real application and convincing results are achieved.
Abstract: A bird strike can cause damage to stationary and
rotating aircraft engine parts, especially the engine fan. This paper
presents a bird strike simulated by blocking four stator blade
passages. It includes the numerical results of the unsteady lowfrequency
aerodynamic forces and the aeroelastic behaviour caused
by a non-symmetric upstream flow affecting the first two rotor blade
stages in the axial-compressor of a jet engine. The obtained results
show that disturbances in the engine inlet strongly influence the level
of unsteady forces acting on the rotor blades. With a partially
blocked inlet the whole spectrum of low-frequency harmonics is
observed. Such harmonics can lead to rotor blade damage. The lowfrequency
amplitudes are higher in the first stage rotor blades than in
the second stage. In both rotor blades stages flutter appeared as a
result of bird strike.
Abstract: Laboratory classes in Electrical Engineering are often hampered by safety issues, as students have to work on high voltage lines. One solution is to make use of virtual laboratory simulations, to help students understand the concepts taught in their coursework. In this context, we have conceived and implemented virtual lab experiments in connection with the study of earthing arrangements. In this work, software was developed, which aid student in understanding the working of a residual current device (RCD) in a TT earthing system. Various parameters, such as the earthing resistances, leakage currents and harmonics were included for a TT system with RCD connection.
Abstract: In this article the influence of higher frequency effects
in addition to a special damper design on the electrical behavior of a
synchronous generator main exciter machine is investigated. On the
one hand these machines are often highly stressed by harmonics from
the bridge rectifier thus facing additional eddy current losses. On the
other hand the switching may cause the excitation of dangerous
voltage peaks in resonant circuits formed by the diodes of the
rectifier and the commutation reactance of the machine. Therefore
modern rotating exciters are treated like synchronous generators
usually modeled with a second order equivalent circuit. Hence the
well known Standstill Frequency Response Test (SSFR) method is
applied to a test machine in order to determine parameters for the
simulation. With these results it is clearly shown that higher
frequencies have a strong impact on the conventional equivalent
circuit model. Because of increasing field displacement effects in the
stranded armature winding the sub-transient reactance is even smaller
than the armature leakage at high frequencies. As a matter of fact this
prevents the algorithm to find an equivalent scheme. This issue is
finally solved using Laplace transfer functions fully describing the
transient behavior at the model ports.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.