Abstract: The demand for power supply increases day by day in developing countries like India henceforth demand of reactive power support in the form of ancillary services provider also has been increased. The multi-line and multi-type Flexible alternating current transmission system (FACTS) controllers are playing a vital role to regulate power flow through the transmission line. Unified power flow controller and interline power flow controller can be utilized to control reactive power flow through the transmission line. In a restructured power system, the demand of such controller is being popular due to their inherent capability. The transmission pricing by using reactive power cost allocation through modified matrix methodology has been proposed. The FACTS technologies have quite costly assembly, so it is very useful to apportion the expenses throughout the restructured electricity industry. Therefore, in this work, after embedding the FACTS devices into load flow, the impact on the costs allocated to users in fraction to the transmission framework utilization has been analyzed. From the obtained results, it is clear that the total cost recovery is enhanced towards the Reactive Power flow through the different transmission line for 5 bus test system. The fair pricing policy towards reactive power can be achieved by the proposed method incorporating FACTS controller towards cost recovery of the transmission network.
Abstract: This study is carried out to understand the effects of Static frequency converter (SFC) on large machine. SFC has a feature of four quadrant operations. By virtue of this it can be implemented to run a synchronous machine either as a motor or alternator. This dual mode operation helps a single machine to start & run as a motor and then it can be converted as an alternator whenever required. One such dual purpose machine is taken here for study. This machine is installed at a laboratory carrying out short circuit test on high power electrical equipment. SFC connected with this machine is broadly described in this paper. The same SFC has been modeled with the MATLAB/Simulink software. The data applied on this virtual model are the actual parameters from SFC and synchronous machine. After running the model, simulated machine voltage and current waveforms are validated with the real measurements. Processing of these waveforms is done through Fast Fourier Transformation (FFT) which reveals that the waveforms are not sinusoidal rather they contain number of harmonics. These harmonics are the major cause of generating shaft voltage. It is known that bearings of electrical machine are vulnerable to current flow through it due to shaft voltage. A general discussion on causes of shaft voltage in perspective with this machine is presented in this paper.
Abstract: Electric machines are driven nowadays by static system popularly known as soft starter. This paper describes a thyristor based static frequency converter (SFC) to run a large synchronous machine installed at a short circuit test laboratory. Normally a synchronous machine requires prime mover or some other driving mechanism to run. This machine doesn’t need a prime mover as it operates in dual mode. In the beginning SFC starts this machine as a motor to achieve the full speed. Thereafter whenever required it can be converted to generator mode. This paper begins with the various starting methodology of synchronous machine. Detailed of SFC with different operational modes have been analyzed. Shaft voltage is a very common phenomenon for the machines with static drives. Various causes of shaft voltages in perspective with this machine are the main attraction of this paper.
Abstract: This paper presents an approach for the design of
fuzzy logic power system stabilizers using genetic algorithms. In the
proposed fuzzy expert system, speed deviation and its derivative
have been selected as fuzzy inputs. In this approach the parameters of
the fuzzy logic controllers have been tuned using genetic algorithm.
Incorporation of GA in the design of fuzzy logic power system
stabilizer will add an intelligent dimension to the stabilizer and
significantly reduces computational time in the design process. It is
shown in this paper that the system dynamic performance can be
improved significantly by incorporating a genetic-based searching
mechanism. To demonstrate the robustness of the genetic based
fuzzy logic power system stabilizer (GFLPSS), simulation studies on
multimachine system subjected to small perturbation and three-phase
fault have been carried out. Simulation results show the superiority
and robustness of GA based power system stabilizer as compare to
conventionally tuned controller to enhance system dynamic
performance over a wide range of operating conditions.
Abstract: This paper presents a systematic approach for the
design of power system stabilizer using genetic algorithm and
investigates the robustness of the GA based PSS. The proposed
approach employs GA search for optimal setting of PSS parameters.
The performance of the proposed GPSS under small and large
disturbances, loading conditions and system parameters is tested.
The eigenvalue analysis and nonlinear simulation results show the
effectiveness of the GPSS to damp out the system oscillations. It is
found tat the dynamic performance with the GPSS shows improved
results, over conventionally tuned PSS over a wide range of
operating conditions.