Abstract: This paper deals with the harmonic decontamination of current in an electrical grid by an active shunt filter in order to improve power quality. The contribution of this paper is mainly based on the proposal of a control strategy for an active filter based on Duty Cycle Modulation (DCM). First, three-monophase method is applied for the identification of disturbing currents. A Simulink model of this method is given for one phase of the grid. Secondly, two orders were designed: the first one is the Hysteresis Control and the second one is the DCM Control. Finally, a comparative study of the two controls was performed. The results obtained show a significant improvement in the rate of harmonic distortion for both controls. The harmonic distortion for the Hysteresis control is limited by the non-controllability of the switching frequencies of the inverter's switches and reduces the harmonic distortion rate (THD) to 3.12% as opposed to the DCM control which limits the THD to 2.82% which makes it better.
Abstract: The Q-enhanced LC filters are the most used
architecture in the Bandpass (BP) Continuous-Time (CT)
Delta-Sigma (ΣΔ) modulators, due to their: high frequencies
operation, high linearity than the active filters and a high quality
factor obtained by Q-enhanced technique. This technique consists
of the use of a negative resistance that compensate the ohmic
losses in the on-chip inductor. However, this technique introduces a
zero in the filter transfer function which will affect the modulator
performances in term of Dynamic Range (DR), stability and in-band
noise (Signal-to-Noise Ratio (SNR)). In this paper, we study the
effect of this zero and we demonstrate that a calibration of the
excess loop delay (ELD) is required to ensure the best performances
of the modulator. System level simulations are done for a 2ndorder
BP CT (ΣΔ) modulator at a center frequency of 300MHz. Simulation
results indicate that the optimal ELD should be reduced by 13% to
achieve the maximum SNR and DR compared to the ideal LC-based
ΣΔ modulator.
Abstract: The use of more and more electronic power switches with a nonlinear behavior generates non-sinusoidal currents in distribution networks, which causes damage to domestic and industrial equipment. The multi-level shunt power active filter is subsequently shown to be an adequate solution to the problem raised. Nevertheless, the difficulty of adjusting the active filter DC supply voltage requires another technology to ensure it. In this article, a photovoltaic generator is associated with the DC bus power terminals of the active filter. The proposed system consists of a field of solar panels, three multi-level voltage inverters connected to the power grid and a non-linear load consisting of a six-diode rectifier bridge supplying a resistive-inductive load. Current control techniques of active and reactive power are used to compensate for both harmonic currents and reactive power as well as to inject active solar power into the distribution network. An algorithm of the search method of the maximum power point of type Perturb and observe is applied. Simulation results of the system proposed under the MATLAB/Simulink environment shows that the performance of control commands that reassure the solar power injection in the network, harmonic current compensation and power factor correction.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: Power quality has become a very important issue recently due to the impact on electricity suppliers, equipment manufacturers and customers. Power quality is described as the variation of voltage, current and frequency in a power system. Voltage magnitude is one of the major factors that determine the quality of power. Indeed, custom power technology, the low-voltage counterpart of the more widely known flexible ac transmission system (FACTS) technology, aimed at high-voltage power transmission applications, has emerged as a credible solution to solve many problems relating to power quality problems. There are various power quality problems such as voltage sags, swells, flickers, interruptions and harmonics etc. Active Power Filter (APF) is one of the custom power devices and can mitigate harmonics, reactive power and unbalanced load currents originating from load side. In this study, an extensive review of APF studies, the advantages and disadvantages of each introduced methods are presented. The study also helps the researchers to choose the optimum control techniques and power circuit configuration for APF applications.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.
Abstract: One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results.
Abstract: A new first order all-pass filter topology realized using current controlled current conveyors (CCCIIs) is introduced in this paper. Offered benefits are the high-impedance of the input node, the absence of external resistors because of the usage of CCCIIs with positive and negative intrinsic resistances, the presence of only grounded capacitors, and the capability of electronic adjustment of the phase shift through a single bias current. The correct operation of the introduced topology is conformed through simulation results, while its behavior is evaluated through comparison results.
Abstract: A new circuit topology realizing a first-order currentmode all-pass filter is proposed using two dual-output second generation
current conveyor and two passive components. The circuit possesses low-input and high-output impedance, which makes it ideal
for current-mode systems. The proposed circuit is verified through PSPICE simulation results.
Abstract: The aim of this paper is to identify an optimum
control strategy of three-phase shunt active filters to minimize the total harmonic distortion factor of the supply current. A classical PIPI cascade control solution of the output current of the active filterand the voltage across the DC capacitor based on Modulus–Optimum
criterion is taken into consideration. The control system operation
has been simulated using Matlab-Simulink environment and the results agree with the theoretical expectation. It is shown that there is
an optimum value of the DC-bus voltage which minimizes the supply current harmonic distortion factor. It corresponds to the equality of the apparent power at the output of the active filter and the apparent power across the capacitor. Finally, predicted results are verified experimentally on a MaxSine active power filter.
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: The perfect operation of common Active Filters is depended on accuracy of identification system distortion. Also, using a suitable method in current injection and reactive power compensation, leads to increased filter performance. Due to this fact, this paper presents a method based on predictive current control theory in shunt active filter applications. The harmonics of the load current is identified by using o–d–q reference frame on load current and eliminating the DC part of d–q components. Then, the rest of these components deliver to predictive current controller as a Threephase reference current by using Park inverse transformation. System is modeled in discreet time domain. The proposed method has been tested using MATLAB model for a nonlinear load (with Total Harmonic Distortion=20%). The simulation results indicate that the proposed filter leads to flowing a sinusoidal current (THD=0.15%) through the source. In addition, the results show that the filter tracks the reference current accurately.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: In this paper, we analyze and test a scheme for the
estimation of electrical fundamental frequency signals from the
harmonic load current and voltage signals.
The scheme was based on using two different Multi Layer
Artificial Neural Networks (ML-ANN) one for the current and the
other for the voltage.
This study also analyzes and tests the effect of choosing the
optimum artificial neural networks- sizes which determine the quality
and accuracy of the estimation of electrical fundamental frequency
signals.
The simulink tool box of the Matlab program for the simulation of
the test system and the test of the neural networks has been used.
Abstract: In recent years Operational Transconductance Amplifier based high frequency integrated circuits, filters and systems have been widely investigated. The usefulness of OTAs over conventional OP-Amps in the design of both first order and second order active filters are well documented. This paper discusses some of the tunability issues using the Matlab/Simulink® software which are previously unreported for any commercial OTA. Using the simulation results two first order voltage controlled all pass filters with phase tuning capability are proposed.
Abstract: A new current-mode multifunction filter using minimum number of passive elements is proposed. The proposed filter has single-input and four high-impedance outputs. It uses four passive elements (two capacitors and two resistors) and four dual output second generation current conveyors. Each output provides a different filter response, namely, low-pass, high-pass, band-pass and band-reject. The sensitivity analysis is also carried out on both ideal and non-ideal filter configurations. The validity of the proposed filter is verified through PSPICE simulations.
Abstract: This paper deals with the current space-vector
decomposition in three-phase, three-wire systems on the basis of
some case studies. We propose four components of the current spacevector
in terms of DC and AC components of the instantaneous
active and reactive powers. The term of supplementary useless
current vector is also pointed out. The analysis shows that the current
decomposition which respects the definition of the instantaneous
apparent power vector is useful for compensation reasons only if the
supply voltages are sinusoidal. A modified definition of the
components of the current is proposed for the operation under
nonsinusoidal voltage conditions.
Abstract: A new voltage-mode triple-input single-output multifunction filter using only two current conveyors is presented. The proposed filter which possesses three inputs and single-output can generate all biquadratic filtering functions at the output terminal by selecting different input signal combinations. The validity of the proposed filter is verified through PSPICE simulations.
Abstract: This paper presents a fuzzy logic controlled shunt
active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a
simple method for the calculation of the reference compensation current based of Fast Fourier Transform. This presented filter is able
to operate in both balanced and unbalanced load conditions. A fuzzy
logic based current controller strategy is used to regulate the filter current and hence ensure harmonic free supply current. The validity
of the presented approach in harmonic mitigation is verified via
simulation results of the proposed test system under different loading
conditions.
Abstract: Pulse width modulation (PWM) techniques have been
the subject of intensive research for different industrial and power
sector applications. A large variety of methods, different in concept
and performance, have been newly developed and described. This
paper analyzes the comparative merits of Sinusoidal Pulse Width
Modulation (SPWM) and Space Vector Pulse Width Modulation
(SVPWM) techniques and the suitability of these techniques in a
Shunt Active Filter (SAF). The objective is to select the scheme that
offers effective utilization of DC bus voltage and also harmonic
reduction at the input side. The effectiveness of the PWM techniques
is tested in the SAF configuration with a non linear load. The
performance of the SAF with the SPWM and (SVPWM) techniques
are compared with respect to the THD in source current. The study
reveals that in the context of closed loop SAF control with the
SVPWM technique there is only a minor improvement in THD. The
utilization of the DC bus with SVPWM is also not significant
compared to that with SPWM because of the non sinusoidal
modulating signal from the controller in SAF configuration.