Harmonic Pollution Control of the Electrical Network by Three-Phase Shunt Active Filter: Comparative Study of Controls, by Hysteresis and by Duty Cycle Modulation

This paper deals with the harmonic decontamination of current in an electrical grid by an active shunt filter in order to improve power quality. The contribution of this paper is mainly based on the proposal of a control strategy for an active filter based on Duty Cycle Modulation (DCM). First, three-monophase method is applied for the identification of disturbing currents. A Simulink model of this method is given for one phase of the grid. Secondly, two orders were designed: the first one is the Hysteresis Control and the second one is the DCM Control. Finally, a comparative study of the two controls was performed. The results obtained show a significant improvement in the rate of harmonic distortion for both controls. The harmonic distortion for the Hysteresis control is limited by the non-controllability of the switching frequencies of the inverter's switches and reduces the harmonic distortion rate (THD) to 3.12% as opposed to the DCM control which limits the THD to 2.82% which makes it better.




References:
[1] Mamane Adamou et al, “Dépollution harmonique des réseaux électriques: Etude comparative des commandes, par Modulation de Largeur d’Impulsion et par Hystérésis, des filtres actifs shunts triphasés,” International Journal of Innovation and Applied Studies ISSN 2028-9324, Vol. 28, 2020, pp. 557-566.
[2] M. Abdusalam, P. Poure and S. Saadate, “A new control scheme of hybrid active filter using Self-Tuning-Filter,” Powereng, International Conference on Power Engineering, Energy and Electrical Drives, Setubal, Portugal, 2007.
[3] A. F. Hanna. Nohra, M. Fadel and H. Y. Kanaan, “A novel instantaneous power based control method for afour-wire SAPF operating with highly perturbed mains voltages,” 2016 ieee international conference on industrial technology (icit), taipei, taiwan, 2016 pp. 1236-1241.
[4] Shraddha Dhumal, Jalaja Gundi Poonam Khrid, Manashri Yadav, M.D. Tuljapurkar, “Detection of Harmonicsin distribution System using FFT with case studies,” International Journal for Scientific Research and Development, 2015, Vol.3 Issue 04, pp 75-82.
[5] Farooq Haroon, Chengke Zhou, Mohamed Emad Farrag, “Analysing the harmonic distortion in a distribution system caused by the non-linear residential loads,” International Journal of Smart Grid and Clean Energy, 2013, Vol. 2, Issue, pp. 46-51.
[6] T.P Nna Nna, S. Ndjakomo Essiane, S. Pérabi Ngoffé “Control of an Active Filter by Duty Cycle Modulation (DCM) for the Harmonic Decontamination of a Three-Phase Electrical Network” Journal of Power and Energy Engineering, 2020, Vol.8, pp. 1-14.
[7] M. Abdusalam “Structures et stratégies de commande des filtres actifs parallèles et hybrides avec validations expérimentales” Thèse de doctorat, Université Henri Poincaré-Nancy I France 2008.
[8] Chaoui Abdelmadjid, “Filtrage actif triphasé pour charges non linéaires,” thèse de doctorat L’université de setif, 2010.
[9] A. Morsli et al “Dépollution des réseaux électriques basse tension utilisant un filtre actif parallèle à deux niveaux contrôlé par l’algorithme P-Q,” Médiamira Science, 2012, Vol.53, pp. 105-111.
[10] A. L. Dourari, M. K. Fellah “Application d’un Filtre Actif Parallèle au Contrôle de la Tension d’un Réseau à Haute Tension, ” Conférence Nationale sur la Haute Tension, Laghouat, ALGERIE, Avril 2013.
[11] Makawana Mukundkumar M., Swapnil Arya “Design of Active Shunt Filter for Harmonics Reduction at Load Side for Power Quality Improvement,” International Conference & Expo on “Advances in Power Generation from Renewable Energy Sources APGRES 2017.
[12] R. Senthil kumar et al, “Reduction and Elimination of Harmonics using Power Active Harmonic Filter,” International Journal of Recent Technology and Engineering (IJRTE) ISSN: 2277-3878, Volume-8, Issue-2S3, July 2019.
[13] Mbihi, J., Ndjali Beng, F., Mbouenda, M., “Modeling and simulation of a class of duty-cycle modulators for industrial instrumentation,” Iranian Journal of Electrical and Computer engineering, 4 (2)2, pp. 121-128, 2005.
[14] Mbihi, J., Ndjali Beng, F., Kom, M., and Nneme Nneme, L. “A novel analog-to-digital conversion technique using nonlinear duty-cycle modulation,” International Journal of electronics and computer science engineering, 1(3), pp. 818-825, 2012.
[15] Mbihi, J., Nneme Nneme, L. “A novel control scheme for buck power converters using duty-cycle modulation,” International Journal of power electronics and computer science engineering, 5(3), pp. 185-199, 2013.
[16] Moffo Lonla B., Jean Mbihi, Leandre Nneme Nneme, “A Low Cost and High Quality Duty–Cycle Modulation Scheme and Applications,” International Journal of Electrical, Computer, Energetic, Electronic and communication Engineering, 8(3):82p–88p, 2014.
[17] A. Obono Biyobo, L. Nneme Nneme, J. Mbihi “A Novel Sine Duty-Cycle Modulation Control Scheme for Photovoltaic Single-Phase Power Inverters,” Wseas Transactions on Circuits and Systems, Vol. 17, 2018.
[18] Liva Falisoa Rafanotsimiva, Gildas Besançon, Didier Georges, Eric Jean Roy Sambatra et Jean Marie Razafimahenina, “Modélisation multimodèle et commande par compensation parallèle distribuée d’un système SMIB, ” Mada-ENELSA, 2013, Vol. 1, pp .9-14.
[19] Gupta Shuvashis Das, Raihan Faruq, Ashraful Bari Chowdhury “A comparative stady on harmonics of different electric Bulbs,” American Journal of Engineering Research (AJER), 2016, Vol. 5, pp. 156-166.
[20] G. Sonfack, J. Mbihi, B. Lonla Moffo, “Optimal Duty Cycle Modulation Scheme for AnalogTo-Digital Conversion Systems,” International Journal of Electronics and Communication Engineering, 2017, Vol.1, pp. 354-360.
[21] R. Senthil kumar et al “Reduction and Elimination of Harmonics using Power Active Harmonic Filter,” International Journal of Recent Technology and Engineering (IJRTE). ISSN: 2277-3878, Vol.8, Issue-2S3, July 2019.