Abstract: In this paper the reference current for Voltage Source
Converter (VSC) of the Shunt Active Power Filter (SAPF) is
generated using Synchronous Reference Frame method,
incorporating the PI controller with anti-windup scheme. The
proposed method improves the harmonic filtering by compensating
the winding up phenomenon caused by the integral term of the PI
controller.
Using Reference Frame Transformation, the current is transformed
from om a - b - c stationery frame to rotating 0 - d - q frame. Using
the PI controller, the current in the 0 - d - q frame is controlled to
get the desired reference signal. A controller with integral action
combined with an actuator that becomes saturated can give some
undesirable effects. If the control error is so large that the integrator
saturates the actuator, the feedback path becomes ineffective because
the actuator will remain saturated even if the process output changes.
The integrator being an unstable system may then integrate to a very
large value, the phenomenon known as integrator windup.
Implementing the integrator anti-windup circuit turns off the
integrator action when the actuator saturates, hence improving the
performance of the SAPF and dynamically compensating harmonics
in the power network. In this paper the system performance is
examined with Shunt Active Power Filter simulation model.
Abstract: Fluorescent and WOLED are widely used because it consumes less energy. However, both lamps cause a harmonics because it has semiconductors components. Harmonic is a distorted sinusoidal electric wave and cause excess heat. This study compares the amount of harmonics generated by both lamps. The test shows that both lamps have THDv(Total Harmonics Distortion of Voltage) almost the same with average 2.5% while the average of WOLED's THDi(Total Harmonics Distortion of Current) is lower than fluorescent has. The average WOLED's THDi is 29.10 % and fluorescent's 'THDi is 87. 23 %.
Abstract: In this paper we discuss the behaviour of the longitudinal modes of a magnetized non collisional plasma subjected to an external electromagnetic field. We apply a semiclassical formalism, with the electrons being studied in a quantum mechanical viewpoint whereas the electromagnetic field in the classical context. We calculate the dielectric function in order to obtains the modes and found that, unlike the Bernstein modes, the presence of radiation induces oscillations around the cyclotron harmonics, which are smoothed as the energy stored in the radiation field becomes small compared to the thermal energy of the electrons. We analyze the influence of the number of photon involved in the electronic transitions between the Landau levels and how the parameters such as the external fields strength, plasma density and temperature affect the dispersion relation
Abstract: Nowadays Multilevel inverters are widely using in various applications. Modulation strategy at fundamental switching frequency like, SHEPWM is prominent technique to eliminate lower order of harmonics with less switching losses and better harmonic profile. The equations which are formed by SHE are highly nonlinear transcendental in nature, there may exist single, multiple or even no solutions for a particular MI. However, some loads such as electrical drives, it is required to operate in whole range of MI. In order to solve SHE equations for whole range of MI, intelligent techniques are well suited to solve equations so as to produce lest %THDV. Hence, this paper uses Continuous genetic algorithm for minimising harmonics. This paper also presents wavelet based analysis of harmonics. The developed algorithm is simulated and %THD from FFT analysis and Wavelet analysis are compared. MATLAB programming environment and SIMULINK models are used whenever necessary.
Abstract: Multilevel inverters supplied from equal and constant
dc sources almost don-t exist in practical applications. The variation
of the dc sources affects the values of the switching angles required
for each specific harmonic profile, as well as increases the difficulty
of the harmonic elimination-s equations. This paper presents an
extremely fast optimal solution of harmonic elimination of multilevel
inverters with non-equal dc sources using Tanaka's fuzzy linear
regression formulation. A set of mathematical equations describing
the general output waveform of the multilevel inverter with nonequal
dc sources is formulated. Fuzzy linear regression is then
employed to compute the optimal solution set of switching angles.
Abstract: This paper presents the experimental results of
discharge current phenomena on various humidity, temperature,
pressure and pollutant conditions of epoxy resin specimen. The
leakage distance of specimen was 3 cm, that it was supplied by high
voltage. The polluted condition was given with NaCl artificial
pollutant. The conducted measurements were discharge current and
applied voltage. The specimen was put in a hermetically sealed
chamber, and the current waveforms were analyzed with FFT.
The result indicated that on discharge condition, the fifth
harmonics still had dominant, rather than third one. The third
harmonics tent to be appeared on low pressure heavily polluted
condition, and followed by high humidity heavily polluted condition.
On the heavily polluted specimen, the peaks discharge current points
would be high and more frequent. Nevertheless, the specimen still
had capacitive property. Besides that, usually discharge current
points were more frequent. The influence of low pressure was still
dominant to be easier to discharge. The non-linear property would be
appear explicitly on low pressure and heavily polluted condition.
Abstract: Based on experimental data using accelerometry technology there was developed an analytical model that approximates human induced ground reaction forces in vertical, longitudinal and lateral directions ascending and descending the stairs. Proposed dynamic loading factors and corresponding phase shifts for the first five harmonics of continuous walking force history in case of stair ascend and descend. Into account is taken imperfectness of individual footfall forcing functions, differences between continuous walking force histories among individuals. There is proposed mean synthetic continuous walking force history that can be used in numerical simulations of human movement on the stairs.
Abstract: Selective harmonic elimination-pulse width modulation techniques offer a tight control of the harmonic spectrum of a given voltage waveform generated by a power electronic converter along with a low number of switching transitions. Traditional optimization methods suffer from various drawbacks, such as prolonged and tedious computational steps and convergence to local optima; thus, the more the number of harmonics to be eliminated, the larger the computational complexity and time. This paper presents a novel method for output voltage harmonic elimination and voltage control of PWM AC/AC voltage converters using the principle of hybrid Real-Coded Genetic Algorithm-Pattern Search (RGA-PS) method. RGA is the primary optimizer exploiting its global search capabilities, PS is then employed to fine tune the best solution provided by RGA in each evolution. The proposed method enables linear control of the fundamental component of the output voltage and complete elimination of its harmonic contents up to a specified order. Theoretical studies have been carried out to show the effectiveness and robustness of the proposed method of selective harmonic elimination. Theoretical results are validated through simulation studies using PSIM software package.
Abstract: Solar Cells are destined to supply electric energy beginning from primary resources. It can charge a battery up to 12V dc. For residential use an inverter for 12V dc to 220Vac conversion is desired. For this a static DC-AC converter is necessarily inserted between the solar cells and the distribution network. This paper describes a new P.W.M. strategy for a voltage source inverter. This modulation strategy reduces the energy losses and harmonics in the P.W.M. voltage source inverter. This technique allows the P.W.M. voltage source inverter to become a new feasible solution for solar home application.
Abstract: This paper presents an optimal design of poly-phase induction motor using Quadratic Interpolation based Particle Swarm Optimization (QI-PSO). The optimization algorithm considers the efficiency, starting torque and temperature rise as objective function (which are considered separately) and ten performance related items including harmonic current as constraints. The QI-PSO algorithm was implemented on a test motor and the results are compared with the Simulated Annealing (SA) technique, Standard Particle Swarm Optimization (SPSO), and normal design. Some benchmark problems are used for validating QI-PSO. From the test results QI-PSO gave better results and more suitable to motor-s design optimization. Cµ code is used for implementing entire algorithms.
Abstract: Personal computers draw non-sinusoidal current
with odd harmonics more significantly. Power Quality of
distribution networks is severely affected due to the flow of these
generated harmonics during the operation of electronic loads. In
this paper, mathematical modeling of odd harmonics in current like
3rd, 5th, 7th and 9th influencing the power quality has been presented.
Live signals have been captured with the help of power quality
analyzer for analysis purpose. The interesting feature is that Total
Harmonic Distortion (THD) in current decreases with the increase
of nonlinear loads has been verified theoretically. The results
obtained using mathematical expressions have been compared with
the practical results and exciting results have been found.
Abstract: This paper proposes a synchronized random switching frequency pulse width modulation (SRSFPWM). In this technique, the clock signal is used to control the random noise frequency which is produced by the feedback voltage of a hysteresis circuit. These make the triangular carrier frequency equaling to the random noise frequency in each switching period with the symmetrical positive and negative slopes of triangular carrier. Therefore, there is no error voltage in PWM signal. The PSpice simulated results shown the proposed technique improved the performance in case of low frequency harmonics of PWM signal comparing with conventional random switching frequency PWM.
Abstract: A numerical method for solving the time-independent Schrödinger equation of a particle moving freely in a three-dimensional
axisymmetric region is developed. The boundary of the region
is defined by an arbitrary analytic function. The method uses a
coordinate transformation and an expansion in eigenfunctions. The
effectiveness is checked and confirmed by applying the method to a
particular example, which is a prolate spheroid.
Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: This paper, a simple continuous conduction mode (CCM) pulse-width-modulated (PWM) controller for high power factor boost converters is introduced. The duty ratios were obtained by the comparison of a sensed signal from inductor current or switch current and a negative slope ramp carrier waveform in each switching period. Due to the proposed control requires only the inductor current or switch current sensor and the output voltage sensor, its circuit implementation was very simple. To verify the proposed control, the circuit experimentation of a 350 W boost converter with the proposed control was applied. From the results, the input current waveform was shaped to be closely sinusoidal, implying high power factor and low harmonics.
Abstract: Wind turbines with double output induction
generators can operate at variable speed permitting conversion
efficiency maximization over a wide range of wind velocities. This
paper presents the performance analysis of a wind driven double
output induction generator (DOIG) operating at varying shafts speed.
A periodic transient state analysis of DOIG equipped with two
converters is carried out using a hybrid induction machine model.
This paper simulates the harmonic content of waveforms in various
points of drive at different speeds, based on the hybrid model
(dqabc). Then the sinusoidal and trapezoidal pulse-width–modulation
control techniques are used in order to improve the power factor of
the machine and to weaken the injected low order harmonics to the
supply. Based on the frequency spectrum, total harmonics distortion,
distortion factor and power factor. Finally advantages of sinusoidal
and trapezoidal pulse width modulation techniques are compared.
Abstract: Most electrical distribution systems are incurring large
losses as the loads are wide spread, inadequate reactive power
compensation facilities and their improper control. A typical static
VAR compensator consists of capacitor bank in binary sequential
steps operated in conjunction with a thyristor controlled reactor of the
smallest step size. This SVC facilitates stepless control of reactive
power closely matching with load requirements so as to maintain
power factor nearer to unity. This type of SVC-s requiring a
appropriately controlled TCR. This paper deals with an air cored
reactor suitable for distribution transformer of 3phase, 50Hz, Dy11,
11KV/433V, 125 KVA capacity. Air cored reactors are designed,
built, tested and operated in conjunction with capacitor bank in five
binary sequential steps. It is established how the delta connected TCR
minimizes the harmonic components and the operating range for
various electrical quantities as a function of firing angle is
investigated. In particular firing angle v/s line & phase currents, D.C.
components, THD-s, active and reactive powers, odd and even triplen
harmonics, dominant characteristic harmonics are all investigated and
range of firing angle is fixed for satisfactory operation. The harmonic
spectra for phase and line quantities at specified firing angles are
given. In case the TCR is operated within the bound specified in this
paper established through simulation studies are yielding the best
possible operating condition particularly free from all dominant
harmonics.
Abstract: It is known that if harmonic spectra are decreased, then
acoustic noise also decreased. Hence, this paper deals with a new
random switching strategy using DSP TMS320F2812 to decrease the
harmonics spectra of single phase switched reluctance motor. The
proposed method which combines random turn-on, turn-off angle
technique and random pulse width modulation technique is shown. A
harmonic spread factor (HSF) is used to evaluate the random
modulation scheme. In order to confirm the effectiveness of the new
method, the experimental results show that the harmonic intensity of
output voltage for the proposed method is better than that for
conventional methods.
Abstract: This paper presents a fast and efficient on-line technique for estimating impedance of unbalanced loads in power systems. The proposed technique is an application of a discrete timedynamic filter based on stochastic estimation theory which is suitable for estimating parameters in noisy environment. The algorithm uses sets of digital samples of the distorted voltage and current waveforms of the non-linear load to estimate the harmonic contents of these two signal. The non-linear load impedance is then calculated from these contents. The method is tested using practical data. Results are reported and compared with those obtained using the conventional least error squares technique. In addition to the very accurate results obtained, the method can detect and reject bad measurements. This can be considered as a very important advantage over the conventional static estimation methods such as the least error square method.