Abstract: This study presents design of a carbon silicon electrode
for iontophorsis treatment towards alopecia. The alopecia is a medical
description means loss of hair from the body. For solving this problem,
the drug need to be delivered into the scalp, therefore, the
iontophoresis was chosen to use in this treatment. However, almost
common electrodes of iontophoresis device are made with metal
material, the electrodes could give patients hurt when they using it, and
it is hard to avoid the hair for attaching the hair. For this reason, an
electrode is made with silicon material to decrease the hurt from the
electrodes, and the carbon material is mixed in it for increasing
conductance. The several cones with stainless material on the
electrode make the electrode is able to void hair to attach the affected
part. According to the results of a vivo-experiment, the carbon silicon
electrode showed a good performance and in treatment comfortably.
Abstract: The purpose of suspension system in automobiles is to
improve the ride comfort and road handling. In this research the ride
and handling performance of a specific automobile with passive
suspension system is compared to a proposed fuzzy logic semi active
suspension system designed for that automobile. The bodysuspension-
wheel system is modeled as a two degree of freedom
quarter car model. MATLAB/SIMULINK [1] was used for
simulation and controller design. The fuzzy logic controller is based
on two inputs namely suspension velocity and body velocity. The
output of the fuzzy controller is the damping coefficient of the
variable damper. The result shows improvement over passive
suspension method.
Abstract: Automotive suspension system is important part of car
comfort and safety. In this article automotive active suspension with
linear motor as actuator is designed using H-infinity control. This
paper is focused on comparison of different controller designed for
quart, half or full-car model (and always used for “full" car). Special
attention is placed on energy demand of the whole system. Each
controller configuration is simulated and then verified on the
hydraulic quarter car test bed.
Abstract: The objective of this study is to present the test
results of variable air volume (VAV) air conditioning system
optimized by two objective genetic algorithm (GA). The objective
functions are energy savings and thermal comfort. The optimal set
points for fuzzy logic controller (FLC) are the supply air temperature
(Ts), the supply duct static pressure (Ps), the chilled water
temperature (Tw), and zone temperature (Tz) that is taken as the
problem variables. Supply airflow rate and chilled water flow rate are
considered to be the constraints. The optimal set point values are
obtained from GA process and assigned into fuzzy logic controller
(FLC) in order to conserve energy and maintain thermal comfort in
real time VAV air conditioning system. A VAV air conditioning
system with FLC installed in a software laboratory has been taken for
the purpose of energy analysis. The total energy saving obtained in
VAV GA optimization system with FLC compared with constant air
volume (CAV) system is expected to achieve 31.5%. The optimal
duct static pressure obtained through Genetic fuzzy methodology
attributes to better air distribution by delivering the optimal quantity
of supply air to the conditioned space. This combination enhanced
the advantages of uniform air distribution, thermal comfort and
improved energy savings potential.
Abstract: Increasing user comfort and reducing operation costs
have always been primary objectives of lighting control strategies in a
building. This paper proposes an architecture of the lighting control
system for a daylit office. The system consists of the lighting
controller, A/D & D/A converter, dimmable LED lights, and the
lighting management software. Verification tests are conducted using
the proposed system specialized for the interior lighting of a open-plan
office. The results showed the proposed architecture of the lighting
system would improve the overall system reliability, lower the system
cost, and provide ease of installation and maintenance.
Abstract: Deep Brain Stimulation or DBS is a surgical treatment for Parkinson-s Disease with three stimulation parameters: frequency, pulse width, and voltage. The parameters should be selected appropriately to achieve effective treatment. This selection now, performs clinically. The aim of this research is to study chaotic behavior of recorded tremor of patients under DBS in order to present a computational method to recognize stimulation optimum voltage. We obtained some chaotic features of tremor signal, and discovered embedding space of it has an attractor, and its largest Lyapunov exponent is positive, which show tremor signal has chaotic behavior, also we found out, in optimal voltage, entropy and embedding space variance of tremor signal have minimum values in comparison with other voltages. These differences can help neurologists recognize optimal voltage numerically, which leads to reduce patients' role and discomfort in optimizing stimulation parameters and to do treatment with high accuracy.
Abstract: In our modern society electricity is vital to our health,
safety, comfort and well-being. While our daily use of electricity is
often taken for granted, public concern has arisen about potential
adverse health effects from electric and magnetic – electromagnetic –
fields (EMFs) produced by our use of electricity.
This paper aims to compare between the measured magnetic field
values and the simulated models for the indoor medium to low
voltage (MV/LV) distribution substations.
To calculate the magnetic flux density in the substations,
interactive software SUBCALC is used which is based on closed
form solution of the Biot-Savart law with 3D conductor model.
The comparison between the measured values and the simulated
models was acceptable. However there were some discrepancies, as
expected, may be due to the current variation during measurements.
Abstract: The paper describes ergonomics problems trend of
student at B5101 classroom building 2, Suranaree University of
Technology. The objective to survey ergonomics problems and effect
from use chairs for sitting in class room. The result from survey
method 100 student they use lecture chair for sitting in classroom
more than 2 hours/ day by RULA[1]. and Body discomfort survey[2].
The result from Body discomfort survey contribute fatigue problems
at neck, lower back, upper back and right shoulder 2.93, 2.91, 2.33,
1.75 respectively and result from RULA contribute fatigue problems
at neck, body and right upper arm 4.00, 3.75 and 3.00 respectively
are consistent. After that the researcher provide improvement plan
for design new chair support student fatigue reduction by prepare
data of sample anthropometry and design ergonomics chair prototype
3 unit. Then sample 100 student trial to use new chair and evaluate
again by RULA, Body discomfort and satisfaction. The result from
trial new chair after improvement by RULA present fatigue reduction
average of head and neck from 4.00 to 2.25 , body and trunk from
3.75 to 2.00 and arm force from 1.00 to 0.25 respectively. The result
from trial new chair after improvement by Body discomfort present
fatigue reduction average of lower back from 2.91 to 0.87, neck from
2.93 to 1.24, upper back 2.33 to 0.84 and right upper arm from 1.75
to 0.74. That statistical of RULA and Body discomfort survey
present fatigue reduction after improvement significance with a
confidence level of 95% (p-value 0.05). When analyzing the
relationship of fatigue as part of the body by Chi – square test during
RULA and Body discomfort that before and after improvements were
consistent with the significant level of confidence 95% (p-value 0.05)
. Moreover the students satisfaction result from trial with a new chair
for 30 minutes [3]. 72 percent very satisfied of the folding of the
secondary writing simple 66% the width of the writing plate, 64% the
suitability of the writing plate, 62% of soft seat cushion and 61%
easy to seat the chair.
Abstract: So much energy is used in high rise buildings to fulfill
the basic needs of users such as lighting and thermal comfort.
Malaysia has hot and humid climate, buildings especially high rise
buildings receive unnecessary solar radiation that cause more solar
heat gain. Energy use specially electricity consumption in high rise
buildings has increased. There have been growing concerns about
energy consumption and its effect on environment. Building, energy
and the environment are important issues that the designers should
consider to them. Self protected form is one of possible ways against
the impact of solar radiation in high rise buildings. The Energy
performance of building envelopes was investigated in term of the
Overall Thermal Transfer Value (OTTV ).In this paper, the amount
of OTTV reduction was calculated through OTTV Equations to
clear the effectiveness of self shading strategy on minimizing energy
consumption for cooling interior spaces in high rise buildings which
has considerable envelope areas against solar radiation. Also increasing
the optimum window area was investigated using self-shading
strategy in designing high rise buildings. As result, the significant
reduction in OTTV was shown based on WWR.In addition slight
increase was demonstrated in WWR that can influence on visible
comfort interior spaces.
Abstract: The automatic transmission (AT) is one of the most
important components of many automobile transmission systems. The
shift quality has a significant influence on the ride comfort of the
vehicle. During the AT shift process, the joint elements such as the
clutch and bands engage or disengage, linking sets of gears to create a
fixed gear ratio. Since these ratios differ between gears in a fixed gear
ratio transmission, the motion of the vehicle could change suddenly
during the shift process if the joint elements are engaged or disengaged
inappropriately, additionally impacting the entire transmission system
and increasing the temperature of connect elements.The objective was
to establish a system model for an AT powertrain using
Matlab/Simulink. This paper further analyses the effect of varying
hydraulic pressure and the associated impact on shift quality during
both engagment and disengagement of the joint elements, proving that
shift quality improvements could be achieved with appropriate
hydraulic pressure control.
Abstract: In this study, we discussed the effects on the thermal
comfort of super high-rise residences that how effected by the high
thermal capacity structural components. We considered different
building orientations, structures, and insulation methods. We used the
dynamic simulation software THERB (simulation of the thermal
environment of residential buildings). It can estimate the temperature,
humidity, sensible temperature, and heating/cooling load for multiple
buildings. In the past studies, we examined the impact of
air-conditioning loads (hereinafter referred to as AC loads) on the
interior structural parts and the AC-usage patterns of super-high-rise
residences.
Super-high-rise residences have more structural components such
as pillars and beams than do ordinary apartment buildings. The
skeleton is generally made of concrete and steel, which have high
thermal-storage capacities. The thermal-storage capacity of
super-high-rise residences is considered to have a larger impact on the
AC load and thermal comfort than that of ordinary residences.
We show that the AC load of super-high-rise units would be
reduced by installing insulation on the surfaces of interior walls that
are not usually insulated in Japan.
Abstract: The aim of this study is to analyze influence of
differences of heat insulation methods on indoor thermal environment and comfort of apartment buildings.
This study analyzes indoor thermal environment and comfort on units of apartment buildings using calculation software "THERB" and
compares three different kinds of heat insulation methods. Those are
outside insulation on outside walls, inside insulation on outside walls and interior insulation. In terms of indoor thermal environment, outside insulation is the best to stabilize room temperature. In winter, room temperature on
outside insulation after heating is higher than other and it is kept 3-5 degrees higher through all night. But the surface temperature with
outside insulation did not dramatically increase when heating was used, which was 3 to 5oC lower than the temperature with other
insulation. The PMV of interior insulation fall nearly range of comfort when the heating and cooling was use.
Abstract: The 'wind-rain' house has a courtyard with glazed
roof, which allows more direct sunlight to come into indoor spaces
during the winter. The glazed roof can be partially opened or closed
and automatically controlled to provide natural ventilation in order to
adjust for indoor thermal conditions and the roof area can be shaded
by reflective insulation materials during the summer. Two field
studies for evaluating indoor thermal conditions of the two 'windrain'
houses have been carried out by author in 2009 and 2010.
Indoor and outdoor air temperature and relative humidity adjacent to
floor and ceiling of the two sample houses were continuously tested
at 15-minute intervals, 24 hours a day during the winter months.
Based on field study data, this study investigates relationships
between building design and indoor thermal condition of the 'windrain'
house to improve the future house design for building thermal
comfort and energy efficiency
Abstract: The antioxidant capability of beverage blends made from cocoa, zobo and ginger with standard antioxidant assay procedures was investigated. The DPPH (2,2-diphenyl-1- picrylhydrazyl) scavenging capacity ranged from 21.2-25.8% in comparison with GSH of 37.1%. The ferric reducing ability was highest in the zobo drink and lowest in ginger. The superoxide scavenging capacity was also highest in the zobo drink followed by the drink with alkalized cocoa. The metal chelating power decreased as the level of zobo in the blends decreases. The chelating power of zobo and ginger were significantly lower than the natural and alkalized cocoa. The 100% zobo drink inhibited linoleic acid till the fifth day while natural and alkalized cocoa as well as the blend with 50% alkalized cocoa inhibited linoleic acid greatly till the sixth day. The finding describes the potential health benefit of the phytochemical antioxidants of cocoa:zobo:ginger beverage blends.
Abstract: Our objectives were to evaluate the effects of sire
breed, type of protein supplement, level of supplementation and sex
on wool spinning fineness (SF), its correlations with other wool
characteristics and prediction accuracy in F1 Merino crossbred lambs.
Texel, Coopworth, White Suffolk, East Friesian and Dorset rams
were mated with 500 purebred Merino dams at a ratio of 1:100 in
separate paddocks within a single management system. The F1
progeny were raised on ryegrass pasture until weaning, before forty
lambs were randomly allocated to treatments in a 5 x 2 x 2 x 2
factorial experimental design representing 5 sire breeds, 2
supplementary feeds (canola or lupins), 2 levels of supplementation
(1% or 2% of liveweight) and sex (wethers or ewes). Lambs were
supplemented for six weeks after an initial three weeks of adjustment,
wool sampled at the commencement and conclusion of the feeding
trial and analyzed for SF, mean fibre diameter (FD), coefficient of
variation (CV), standard deviation, comfort factor (CF), fibre
curvature (CURV), and clean fleece yield. Data were analyzed using
mixed linear model procedures with sire fitted as a random effect,
and sire breed, sex, supplementary feed type, level of
supplementation and their second-order interactions as fixed effects.
Sire breed (P
Abstract: This paper systematically investigates the timedependent
health outcomes for office staff during computer work
using the developed mathematical model. The model describes timedependent
health outcomes in multiple body regions associated with
computer usage. The association is explicitly presented with a doseresponse
relationship which is parametrized by body region
parameters. Using the developed model we perform extensive
investigations of the health outcomes statically and dynamically. We
compare the risk body regions and provide various severity rankings
of the discomfort rate changes with respect to computer-related
workload dynamically for the study population. Application of the
developed model reveals a wide range of findings. Such broad
spectrum of investigations in a single report literature is lacking.
Based upon the model analysis, it is discovered that the highest
average severity level of the discomfort exists in neck, shoulder, eyes,
shoulder joint/upper arm, upper back, low back and head etc. The
biggest weekly changes of discomfort rates are in eyes, neck, head,
shoulder, shoulder joint/upper arm and upper back etc. The fastest
discomfort rate is found in neck, followed by shoulder, eyes, head,
shoulder joint/upper arm and upper back etc. Most of our findings are
consistent with the literature, which demonstrates that the developed
model and results are applicable and valuable and can be utilized to
assess correlation between the amount of computer-related workload
and health risk.
Abstract: Today-s Wi Fi generation utilize the latest technology in their daily lives. Instructors at National University, the second largest non profit private institution of higher learning in California, are incorporating these new tools to modify their Online class formats to better accommodate these new skills in their distance education delivery modes. The University provides accelerated learning in a one-course per month format both Onsite and Online. Since there has been such a significant increase in Online classes over the past three years, and it is expected to grow even more over the over the next five years, Instructors cannot afford to maintain the status quo and not take advantage of these new options. It is at the discretion of the instructors which accessory they use and how comfortable and familiar they are with the technology. This paper explores the effects and summarizes students- comments of some of these new technological options which have been recently provided in order to make students- online learning experience more exciting and meaningful.
Abstract: This paper describes the development, modeling, and
testing of skyhook and MiniMax control strategies of semi-active
suspension. The control performances are investigated using
Matlab/Simulink [1], with a two-degree-of-freedom quarter car semiactive
suspension system model. The comparison and evaluation of
control result are made using software-in-the-loop simulation (SILS)
method. This paper also outlines the development of a hardware-inthe-
loop simulation (HILS) system. The simulation results show that
skyhook strategy can significantly reduce the resonant peak of body
and provide improvement in vehicle ride comfort. Otherwise,
MiniMax strategy can be employed to effectively improve drive
safety of vehicle by influencing wheel load. The two strategies can
be switched to control semi-active suspension system to fulfill
different requirement of vehicle in different stages.
Abstract: Air conditioning is mainly to be used as human
comfort medium. It has been use more often in country in which the
daily temperatures are high. In scientific, air conditioning is defined
as a process of controlling the moisture, cooling, heating and cleaning
air. Without proper estimation of cooling load, big amount of waste
energy been used because of unsuitable of air conditioning system are
not considering to overcoming heat gains from surrounding. This is
due to the size of the room is too big and the air conditioning has to
use more energy to cool the room and the air conditioning is too
small for the room. The studies are basically to develop a program to
calculate cooling load. Through this study it is easy to calculate
cooling load estimation. Furthermore it-s help to compare the cooling
load estimation by hourly and yearly. Base on the last study that been
done, the developed software are not user-friendly. For individual
without proper knowledge of calculating cooling load estimation
might be problem. Easy excess and user-friendly should be the main
objective to design something. This program will allow cooling load
able be estimate by any users rather than estimation by using rule of
thumb. Several of limitation of case study is judged to sure it-s
meeting to Malaysia building specification. Finally validation is done
by comparison manual calculation and by developed program.
Abstract: Home Automation is a field that, among other
subjects, is concerned with the comfort, security and energy
requirements of private homes. The configuration of automatic
functions in this type of houses is not always simple to its inhabitants
requiring the initial setup and regular adjustments. In this work, the
ubiquitous computing system vision is used, where the users- action
patterns are captured, recorded and used to create the contextawareness
that allows the self-configuration of the home automation
system. The system will try to free the users from setup adjustments
as the home tries to adapt to its inhabitants- real habits. In this paper
it is described a completely automated process to determine the light
state and act on them, taking in account the users- daily habits.
Artificial Neural Network (ANN) is used as a pattern recognition
method, classifying for each moment the light state. The work
presented uses data from a real house where a family is actually
living.