Power Frequency Magnetic Field Survey in Indoor Power Distribution Substation in Egypt

In our modern society electricity is vital to our health, safety, comfort and well-being. While our daily use of electricity is often taken for granted, public concern has arisen about potential adverse health effects from electric and magnetic – electromagnetic – fields (EMFs) produced by our use of electricity. This paper aims to compare between the measured magnetic field values and the simulated models for the indoor medium to low voltage (MV/LV) distribution substations. To calculate the magnetic flux density in the substations, interactive software SUBCALC is used which is based on closed form solution of the Biot-Savart law with 3D conductor model. The comparison between the measured values and the simulated models was acceptable. However there were some discrepancies, as expected, may be due to the current variation during measurements.




References:
[1] "Application of ICNIRP Exposure Guidelines for 50 Hz Power
Frequency Fields", available on http://www.icra.org/ratingsv02.html
[2] Exposure Standards Applicable In Europe and Elsewhere," (Brussels:
Union of the Electricity Industry - EURELECTRIC, May 2003).
[3] A.S. Farag, T. Juhana Hashim, H. Hussain, I. Said, N. Abdul Rahman"
Exposure Assessment of Electromagnetic Fields in Malaysian Public
Schools Environment" , Proceeding of International Conference on
Non-Ionizing Radiation at UNITEN (ICNIR2003),Electromagnetic
Fields and Our Health, 20th-22nd October 2003.
[4] A Hossam El din, K Youssef and H Karawia, "Study
And Evaluation Of Induced Currents In Human Body From Exposure
To Electromagnetic Fields At Low Frequencies," Cired 20th
International Conference on Electricity Distribution, Session 2,paper
no.60, Prague, 8-11 June 2009.
[5] I. Said, A.S. Farag, H. Hussain, N.A. Rahman, "Measurement of
Magnetic Field From Distribution Substations in Malaysia",
Australasian Universities Power Engineering Conference (AUPEC
2004),paper no. 142, 26-29 September 2004, Brisbane, Australia.
[6] ANSI/ IEEE Std 644-1987,IEEE Standard Procedures for Measurement
of Power Frequency Electric and Magnetic Fields from AC Power
Lines.
[7] A Hossam El din, I. Madi and H Karawia," Measurement and Analysis
of Magnetic Fields in MV/LV Distribution Substation in Egypt",13th
International Middle East Power Systems Conference, paper
no.151,December 2009.
[8] H. B. San Segundo, C. C. García, V. F. Roig,T. Y. Vega,"Magnetic
field reduction study for low voltage distribution panels located in
MV/LV substations",19th International Conference, Electrical Power
Quality and Utilization,Barcelona,9-11 October 2007.
[9] I.O.Habiballah, M.M.Dawoud,K.AL Balawi , A.S.Farag,"Magnetic
Field Measurement& Simulation of A 230kV Substatio",Proceeding of
the International Conference on Non- Ionizing Radiation at UNITEN
(ICNIR 2003), Electromagnetic Fileds and Our Health, 20th-21th
October 2003, Malaysia.