Abstract: Multifamily residential buildings are increasingly being built with large glazed areas to provide tenants with greater daylight and outdoor views. However, traditional double-glazed window assemblies can lead to significant thermal discomfort from high radiant temperatures as well as increased cooling energy use to address solar gains. Dynamic glazing provides an effective solution by actively controlling solar transmission to maintain indoor thermal comfort, without compromising the visual connection to outdoors. This study uses thermal simulations across three Canadian cities (Toronto, Vancouver and Montreal) to verify if dynamic glazing along with operable windows and ceiling fans can maintain the indoor operative temperature of a prototype southwest facing high-rise apartment unit within the ASHRAE 55 adaptive comfort range for a majority of the year, without any mechanical cooling. Since this study proposes the use of natural ventilation for cooling and the typical building life cycle is 30-40 years, the typical weather files have been modified based on accepted global warming projections for increased air temperatures by 2050. Results for the prototype apartment confirm that thermal discomfort with dynamic glazing occurs only for less than 0.7% of the year. However, in the baseline scenario with low-E glass there are up to 7% annual hours of discomfort despite natural ventilation with operable windows and improved air movement with ceiling fans.
Abstract: The physical effects of upstream flow obstructions such
as vegetation on cross-ventilation phenomena of a building are
important for issues such as indoor thermal comfort. Modelling such
effects in Computational Fluid Dynamics simulations may also be
challenging. The aim of this work is to establish the cross-ventilation
jet behaviour in such complex terrain conditions as well as to provide
guidelines on the implementation of CFD numerical simulations in
order to model complex terrain features such as vegetation in an
efficient manner. The methodology consists of onsite measurements
on a test cell coupled with numerical simulations. It was found
that the cross-ventilation flow is highly turbulent despite the very
low velocities encountered internally within the test cells. While no
direct measurement of the jet direction was made, the measurements
indicate that flow tends to be reversed from the leeward to the
windward side. Modelling such a phenomenon proves challenging
and is strongly influenced by how vegetation is modelled. A solid
vegetation tends to predict better the direction and magnitude of the
flow than a porous vegetation approach. A simplified terrain model
was also shown to provide good comparisons with observation. The
findings have important implications on the study of cross-ventilation
in complex terrain conditions since the flow direction does not remain
trivial, as with the traditional isolated building case.
Abstract: Passive design responds to improve indoor thermal comfort and minimize the energy consumption. The present research analyzed the how efficiently passive solar technologies generate heating and cooling and provide the system integration for domestic applications. In addition to this, the aim of this study is to increase the efficiency of solar systems system with integration some innovation and optimization. As a result, outputs of the project might start a new sector to provide environmentally friendly and cheap cooling for domestic use.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: A one-dimensional mathematical model was developed in order to analyze and optimize the latent heat storage wall. The governing equations for energy transport were developed by using the enthalpy method and discretized with volume control scheme. The resulting algebraic equations were next solved iteratively by using TDMA algorithm. A series of numerical investigations were conducted in order to examine the effects of the thickness of the PCM layer on the thermal behavior of the proposed heating system. Results are obtained for thermal gain and temperature fluctuation. The charging discharging process was also presented and analyzed.
Abstract: In this study, we discussed the effects on the thermal
comfort of super high-rise residences that how effected by the high
thermal capacity structural components. We considered different
building orientations, structures, and insulation methods. We used the
dynamic simulation software THERB (simulation of the thermal
environment of residential buildings). It can estimate the temperature,
humidity, sensible temperature, and heating/cooling load for multiple
buildings. In the past studies, we examined the impact of
air-conditioning loads (hereinafter referred to as AC loads) on the
interior structural parts and the AC-usage patterns of super-high-rise
residences.
Super-high-rise residences have more structural components such
as pillars and beams than do ordinary apartment buildings. The
skeleton is generally made of concrete and steel, which have high
thermal-storage capacities. The thermal-storage capacity of
super-high-rise residences is considered to have a larger impact on the
AC load and thermal comfort than that of ordinary residences.
We show that the AC load of super-high-rise units would be
reduced by installing insulation on the surfaces of interior walls that
are not usually insulated in Japan.
Abstract: The 'wind-rain' house has a courtyard with glazed
roof, which allows more direct sunlight to come into indoor spaces
during the winter. The glazed roof can be partially opened or closed
and automatically controlled to provide natural ventilation in order to
adjust for indoor thermal conditions and the roof area can be shaded
by reflective insulation materials during the summer. Two field
studies for evaluating indoor thermal conditions of the two 'windrain'
houses have been carried out by author in 2009 and 2010.
Indoor and outdoor air temperature and relative humidity adjacent to
floor and ceiling of the two sample houses were continuously tested
at 15-minute intervals, 24 hours a day during the winter months.
Based on field study data, this study investigates relationships
between building design and indoor thermal condition of the 'windrain'
house to improve the future house design for building thermal
comfort and energy efficiency
Abstract: Natural ventilation is an important means to improve indoor thermal comfort and reduce the energy consumption. A solar chimney system is an enhancing natural draft device, which uses solar radiation to heat the air inside the chimney, thereby converting the thermal energy into kinetic energy. The present study considered some parameters such as chimney width and solar intensity, which were believed to have a significant effect on space ventilation. Fluent CFD software was used to predict buoyant air flow and flow rates in the cavities. The results were compared with available published experimental and theoretical data from the literature. There was an acceptable trend match between the present results and the published data for the room air change per hour, ACH. Further, it was noticed that the solar intensity has a more significant effect on ACH.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. Auckland house design not only focus on winter thermal performance and indoor thermal condition, but also indoor moisture control, which is closely related to indirect health effects such as dust mites, fungi, etc. Most Auckland houses are designed to use temporary heating for winter indoor thermal comfort. Based on field study data of indoor microclimate conditions of two Auckland townhouses with a whole home mechanical ventilation system or a passive wind directional skylight vent, this study is to evaluate and compare indoor moisture conditions of two insulated townhouses only using temporary heating with different ventilation systems.