Abstract: This study is aiming at establishing the relationship
between the optical signal of flame and an equivalent ratio of flame. In
this experiment, flame optical signal in a furnace is measured using
photodiode. The combustion system is composed of metal fiber burner
and vertical furnace, and flame chemiluminescence is measured at
various experimental conditions. In this study, the flame
chemiluminescence of laminar premixed flame is measured using
commercially available photodiode. It is experimentally investigated
the relationship between equivalent ratio and photodiode signal. In
addition, the strategy of combustion control method is proposed using
the optical signal and fuel pressure.
The results showed that certain relationship between optical data of
photodiode and equivalence ratio exists, and this leads to the
successful application of this system for instantaneous measurement of
equivalence ration of the combustion system.
Abstract: In the past decade, the use of digital image correlation
(DIC) techniques has increased significantly in the area of
experimental mechanics, especially for materials behavior
characterization. This non-contact tool enables full field displacement
and strain measurements over a complete region of interest. The DIC
algorithm requires a random contrast pattern on the surface of the
specimen in order to perform properly. To create this pattern, the
specimen is usually first coated using a white matt paint. Next, a
black random speckle pattern is applied using any suitable method. If
the applied paint coating is too thick, its top surface may not be able
to exactly follow the deformation of the specimen, and consequently,
the strain measurement might be underestimated. In the present
article, a study of the influence of the paint thickness on the strain
underestimation is performed for different strain levels. The results
are then compared to typical paint coating thicknesses applied by
experienced DIC users. A slight strain underestimation was observed
for paint coatings thicker than about 30μm. On the other hand, this
value was found to be uncommonly high compared to coating
thicknesses applied by DIC users.
Abstract: The paper presents a novel screening method to
indicate congenital heart diseases (CHD), which otherwise could
remain undetected because of their low level. Therefore, not
belonging to the high-risk population, the pregnancies are not subject
to the regular fetal monitoring with ultrasound echocardiography.
Based on the fact that CHD is a morphological defect of the heart
causing turbulent blood flow, the turbulence appears as a murmur,
which can be detected by fetal phonocardiography (fPCG). The
proposed method applies measurements on the maternal abdomen
and from the recorded sound signal a sophisticated processing
determines the fetal heart murmur. The paper describes the problems
and the additional advantages of the fPCG method including the
possibility of measurements at home and its combination with the
prescribed regular cardiotocographic (CTG) monitoring. The
proposed screening process implemented on a telemedicine system
provides an enhanced safety against hidden cardiac diseases.
Abstract: The effect of partially substitution of magnetic
impurity Fe for Cu to the magnetic and transport properties in
electron-doped superconducting cuprates of
Eu1.85+yCe0.15-yCu1-yFeyO4+α-δ (ECCFO) with y = 0, 0.010, 0.020, and
0.050 has been studied, in order to investigate the mechanism of
magnetic and transport properties of ECCFO in normal-state.
Magnetic properties are investigated by DC magnetic-susceptibility
measurements that carried out at low temperatures down to 2 K using a
standard SQUID magnetometer in a magnetic field of 5 Oe on field
cooling. Transport properties addressed to electron mobility, are
extracted from radius of electron localization calculated from
temperature dependence of resistivity. For y = 0, temperature
dependence of dc magnetic-susceptibility (χ) indicated the change of
magnetic behavior from paramagnetic to diamagnetic below 15 K.
Above 15 K, all samples show paramagnetic behavior with the values
of magnetic moment in every volume unit increased with increasing y.
Electron mobility decreased with increasing y.
Abstract: Background: Worldwide, at least 2.8 million people
die each year as a result of being overweight or obese, and 35.8
million (2.3%) of global DALYs are caused by overweight or
obesity. Obesity is acknowledged as one of the burning public
health problems reducing life expectancy and quality of life. The
body composition analysis of the university population is essential
in assessing the nutritional status, as well as the risk of developing
diseases associated with abnormal body fat content so as to make
nutritional recommendations. Objectives: The main aim was to
determine the prevalence of obesity and overweight in University
students using Anthropometric analysis and BIA methods. Material
and Methods: In this cross-sectional study, 283 university students
participated. The body composition analysis was undertaken by
using mainly: i) Anthropometric Measurement: Height, Weight,
BMI, waist circumference, hip circumference and skin fold
thickness, ii) Bio-electrical impedance was used for analysis of
body fat mass, fat percent and visceral fat which was measured by
Tanita SC-330P Professional Body Composition Analyzer. The
data so collected were compiled in MS Excel and analyzed for
males and females using SPSS 16. Results and Discussion: The
mean age of the male (n= 153) studied subjects was 25.37 ±2.39
years and females (n=130) was 22.53 ±2.31. The data of BIA
revealed very high mean fat per cent of the female subjects i.e.
30.3±6.5 per cent whereas mean fat per cent of the male subjects
was 15.60±6.02 per cent indicating a normal body fat range. The
findings showed high visceral fat of both males (12.92±3.02) and
females (16.86±4.98). BMI, BF% and WHR were higher among
females, and BMI was higher among males. The most evident
correlation was verified between BF% and WHR for female
students (r=0.902; p
Abstract: The aim of this paper is to present the concept of an
agile enterprise model and to initiate discussion on the research
assumptions of the model presented. The implementation of the
research project "The agility of enterprises in the process of adapting
to the environment and its changes" began in August 2014 and is
planned to last three years. The article has the form of a work-inprogress
paper which aims to verify and initiate a debate over the
proposed research model. In the literature there are very few
publications relating to research into agility; it can be concluded that
the most controversial issue in this regard is the method of measuring
agility. In previous studies the operationalization of agility was often
fragmentary, focusing only on selected areas of agility, for example
manufacturing, or analysing only selected sectors. As a result the
measures created to date can only be treated as contributory to the
development of precise measurement tools. This research project
aims to fill a cognitive gap in the literature with regard to the
conceptualization and operationalization of an agile company. Thus,
the original contribution of the author of this project is the
construction of a theoretical model that integrates manufacturing
agility (consisting mainly in adaptation to the environment) and
strategic agility (based on proactive measures). The author of this
research project is primarily interested in the attributes of an agile
enterprise which indicate that the company is able to rapidly adapt to
changing circumstances and behave pro-actively.
Abstract: All current experimental methods for determination of
stress intensity factors are based on the assumption that the state of
stress near the crack tip is plane stress. Therefore, these methods rely
on strain and displacement measurements made outside the near
crack tip region affected by the three-dimensional effects or by
process zone. In this paper, we develop and validate an experimental
procedure for the evaluation of stress intensity factors from the
measurements of the out-of-plane displacements in the surface area
controlled by 3D effects. The evaluation of stress intensity factors is
possible when the process zone is sufficiently small, and the
displacement field generated by the 3D effects is fully encapsulated
by K-dominance region.
Abstract: The atmospheres in many cities along the coastal lines
in the world have been rapidly changed to coastal-industrial
atmosphere. Hence, it is vital to investigate the corrosion behavior of
steel exposed to this kind of environment. In this present study,
Electrochemical Impedance Spectrography (EIS) and film thickness
measurement were applied to monitor the corrosion behavior of
weathering steel covered with a thin layer of the electrolyte in a
wet-dry cyclic condition, simulating a coastal-industrial environment
at 25oC and 60% RH. The results indicate that in all cycles, the
corrosion rate increases during the drying process due to an increase in
anion concentration and an acceleration of oxygen diffusion enhanced
by the effect of the thinning out of the electrolyte. During the wet-dry
cyclic corrosion test, the long-term corrosion behavior of this steel
depends on the periods of exposure. Corrosion process is first
accelerated and then decelerated. The decelerating corrosion process is
contributed to the formation of the protective rust, favored by the
wet-dry cycle and the acid regeneration process during the rusting
process.
Abstract: Pt/γ-Al2O3 membrane catalysts were prepared via an
evaporative-crystallization deposition method. The obtained Pt/γ-
Al2O3 catalyst activity was tested after characterization (SEM-EDAX
observation, BET measurement, permeability assessment) in the
catalytic oxidation of selected volatile organic compound (VOC) i.e.
propane, fed in mixture of oxygen. The VOC conversion (nearly
90%) obtained by varying the operating temperature showed that
flow-through membrane reactor might do better in the abatement of
VOCs.
Abstract: One of the main challenges in using the Discrete
Element Method (DEM) is to specify the correct input parameter
values. In general, the models are sensitive to the input parameter
values and accurate results can only be achieved if the correct values
are specified. For the linear contact model, micro-parameters such as
the particle density, stiffness, coefficient of friction, as well as the
particle size and shape distributions are required. There is a need for
a procedure to accurately calibrate these parameters before any
attempt can be made to accurately model a complete bulk materials
handling system. Since DEM is often used to model applications in
the mining and quarrying industries, a calibration procedure was
developed for materials that consist of relatively large (up to 40 mm
in size) particles. A coarse crushed aggregate was used as the test
material. Using a specially designed large shear box with a diameter
of 590 mm, the confined Young’s modulus (bulk stiffness) and
internal friction angle of the material were measured by means of the
confined compression test and the direct shear test respectively. DEM
models of the experimental setup were developed and the input
parameter values were varied iteratively until a close correlation
between the experimental and numerical results was achieved. The
calibration process was validated by modelling the pull-out of an
anchor from a bed of material. The model results compared well with
experimental measurement.
Abstract: Non contact evaluation of the thickness of paint
coatings can be attempted by different destructive and nondestructive
methods such as cross-section microscopy, gravimetric mass
measurement, magnetic gauges, Eddy current, ultrasound or
terahertz. Infrared thermography is a nondestructive and non-invasive
method that can be envisaged as a useful tool to measure the surface
thickness variations by analyzing the temperature response. In this
paper, the thermal quadrupole method for two layered samples heated
up with a pulsed excitation is firstly used. By analyzing the thermal
responses as a function of thermal properties and thicknesses of both
layers, optimal parameters for the excitation source can be identified.
Simulations show that a pulsed excitation with duration of ten
milliseconds allows obtaining a substrate-independent thermal
response. Based on this result, an experimental setup consisting of a
near-infrared laser diode and an Infrared camera was next used to
evaluate the variation of paint coating thickness between 60 μm and
130 μm on two samples. Results show that the parameters extracted
for thermal images are correlated with the estimated thicknesses by
the Eddy current methods. The laser pulsed thermography is thus an
interesting alternative nondestructive method that can be moreover
used for nonconductive substrates.
Abstract: Transmission system performance analysis is vital to
proper planning and operations of power systems in the presence of
deregulation. Key performance indicators (KPIs) are often used as
measure of degree of performance. This paper gives a novel method
to determine the transmission efficiency by evaluating the ratio of
real power losses incurred from a specified transfer direction.
Available Transmission Transfer Efficiency (ATTE) expresses the
percentage of real power received resulting from inter-area available
power transfer. The Tie line (Rated system path) performance is seen
to differ from system wide (Network response) performance and
ATTE values obtained are transfer direction specific. The required
sending end quantities with specified receiving end ATC and the
receiving end power circle diagram are obtained for the tie line
analysis. The amount of real power loss load relative to the available
transfer capability gives a measure of the transmission grid
efficiency.
Abstract: We report the microstructural and magnetic properties
of Ni50Mn39Sn11 and Ni50Mn36Sn14 ribbon Heusler alloys.
Experimental results were obtained by differential scanning
calorymetry, X-ray diffraction and vibrating sample magnetometry
techniques. The Ni-Mn-Sn system undergoes a martensitic structural
transformation in a wide temperature range. For example, for
Ni50Mn39Sn11 the start and finish temperatures of the martensitic and
austenite phase transformation for ribbon alloy were Ms=336K,
Mf=328K, As=335K and Af=343K whereas no structural
transformation is observed for Ni50Mn36Sn14 alloys. Magnetic
measurements show the typical ferromagnetic behavior with Curie
temperature 207 K at low applied field of 50 Oe. The complex
behavior exhibited by these Heusler alloys should be ascribed to the
strong coupling between magnetism and structure, being their
magnetic behavior determined by the distance between Mn atoms.
Abstract: Pipa is one of the most important Chinese traditional
plucked instruments, but its directivity has never been measured
systematically. In western, directivity of loudness for western
instruments is deeply researched through analysis of sound pressure
level, whereas the directivity of timbre is seldom studied. In this paper,
a new method for directivity of timbre was proposed, and horizontal
directivity patterns of loudness and timbre of Pipa were measured.
Directivity of Pipa radiation was measured in an anechoic room. The
sound of Pipa played by a musician was recorded simultaneously by
32 microphones with Pipa in the center. The measuring results were
examined through listening test. According to the measurement of
Pipa directivity radiation, we put forward the best localization of Pipa
in the Chinese traditional orchestra and the optimal recording region.
Abstract: The number of persons with implanted cardiac
pacemakers (PM) has increased in Western countries. The aim of this
paper is to investigate the possible situations where persons with a
PM may be exposed to extremely low frequency (ELF) electric (EF)
and magnetic fields (MF) that may disturb their PM. Based on our
earlier studies, it is possible to find such high public exposure to EFs
only in some places near 400 kV power lines, where an EF may
disturb a PM in unipolar mode. Such EFs cannot be found near 110
kV power lines. Disturbing MFs can be found near welding
machines. However, we do not have measurement data from welding.
Based on literature and earlier studies at Tampere University of
Technology, it is difficult to find public EF or MF exposure that is
high enough to interfere with PMs.
Abstract: This paper presents a novel integrated hybrid
approach for fault diagnosis (FD) of nonlinear systems. Unlike most
FD techniques, the proposed solution simultaneously accomplishes
fault detection, isolation, and identification (FDII) within a unified
diagnostic module. At the core of this solution is a bank of adaptive
neural parameter estimators (NPE) associated with a set of singleparameter
fault models. The NPEs continuously estimate unknown
fault parameters (FP) that are indicators of faults in the system. Two
NPE structures including series-parallel and parallel are developed
with their exclusive set of desirable attributes. The parallel scheme is
extremely robust to measurement noise and possesses a simpler, yet
more solid, fault isolation logic. On the contrary, the series-parallel
scheme displays short FD delays and is robust to closed-loop system
transients due to changes in control commands. Finally, a fault
tolerant observer (FTO) is designed to extend the capability of the
NPEs to systems with partial-state measurement.
Abstract: Increasing prevalence of childhood obesity has
increased the interest in early and late indicators of gaining weight.
Cell blood counts may be indicators of pro-inflammatory states. The
aim was to evaluate associations of hematological parameters,
including hematocrit (HTC), hemoglobin, blood cell counts and their
indices with the degree of obesity in pediatric population. A total of
249; -139 morbidly obese (MO), 82 healthy normal weight (NW) and
28 overweight (OW) children were included into the scope of the
study. WHO BMI-for age percentiles were used to form age- and sexmatched
groups. Informed consent forms and the Ethics Committee
approval were obtained. Anthropometric measurements were
performed. Hematological parameters were determined. Statistical
analyses were performed using SPSS. The degree for statistical
significance was p≤0.05. Significant differences (p=0.000) between
waist-to-hip ratios and head-to- neck ratios (hnrs) of MO and NW
children were detected. A significant difference between hnrs of OW
and MO children (p=0.000) was observed. Red cell distribution width
(RDW) was higher in OW children than NW group (p=0.030). Such
finding couldn’t be detected between MO and NW groups. Increased
RDW was prominent in OW children. The decrease in mean
corpuscular hemoglobin concentration (MCHC) values in MO
children was sharper than the values in OW children (p=0.006 vs
p=0.042) compared to those in NW group. Statistically higher HTC
levels were observed between MO-NW (p=0.014), but none between
OW-NW. Though the cause-effect relationship between obesity and
erythrocyte indices still needs further investigation, alterations in
RDW, HTC, MCHC during obesity may be of significance in the
early life.
Abstract: In the current work, a three-dimensional geometry of a
75% stenosed blood vessel is analyzed. Large eddy simulation (LES)
with the help of a dynamic subgrid scale Smagorinsky model is
applied to model the turbulent pulsatile flow. The geometry, the
transmural pressure and the properties of the blood and the elastic
boundary were based on clinical measurement data. For the flexible
wall model, a thin solid region is constructed around the 75%
stenosed blood vessel. The deformation of this solid region was
modelled as a deforming boundary to reduce the computational cost
of the solid model. Fluid-structure interaction is realized via a twoway
coupling between the blood flow modelled via LES and the
deforming vessel. The information of the flow pressure and the wall
motion was exchanged continually during the cycle by an arbitrary
Lagrangian-Eulerian method. The boundary condition of current time
step depended on previous solutions. The fluctuation of the velocity
in the post-stenotic region was analyzed in the study. The axial
velocity at normalized position Z=0.5 shows a negative value near
the vessel wall. The displacement of the elastic boundary was
concerned in this study. In particular, the wall displacement at the
systole and the diastole were compared. The negative displacement at
the stenosis indicates a collapse at the maximum velocity and the
deceleration phase.
Abstract: Background - The TrendCare Patient Dependency
System is currently used by a large number of maternity Services
across Australia, New Zealand and Singapore. In 2012, 2013 and
2014 validation studies were initiated in all three countries to validate
the acuity tools used for women in labour, and postnatal mothers and
babies. This paper will present the findings of the validation study.
Aim - The aim of this study was to; identify if the care hours
provided by the TrendCare acuity system was an accurate reflection
of the care required by women and babies; obtain evidence of
changes required to acuity indicators and/or category timings to
ensure the TrendCare acuity system remains reliable and valid across
a range of maternity care models in three countries.
Method - A non-experimental action research methodology was
used across maternity services in four District Health Boards in New
Zealand, a large tertiary and a large secondary maternity service in
Singapore and a large public maternity service in Australia.
Standardised data collection forms and timing devices were used to
collect midwife contact times, with women and babies included in the
study. Rejection processes excluded samples when care was not
completed/rationed, and contact timing forms were incomplete. The
variances between actual timed midwife/mother/baby contact and the
TrendCare acuity category times were identified and investigated.
Results - Thirty two (88.9%) of the 36 TrendCare acuity category
timings, fell within the variance tolerance levels when compared to
the actual timings recorded for midwifery care. Four (11.1%)
TrendCare categories provided less minutes of care than the actual
timings and exceeded the variance tolerance level. These were all
night shift category timings. Nine postnatal categories were not able
to be compared as the sample size for these categories was
statistically insignificant. 100% of labour ward TrendCare categories
matched actual timings for midwifery care, all falling within the
variance tolerance levels.
The actual time provided by core midwifery staff to assist lead
maternity carer (LMC) midwives in New Zealand labour wards
showed a significant deviation to previous studies. The findings of
the study demonstrated the need for additional time allocations in
TrendCare to accommodate an increased level of assistance given to
LMC midwives.
Conclusion - The results demonstrated the importance of regularly
validating the TrendCare category timings with actual timings of the
care hours provided. It was evident from the findings that variances
to models of care and length of stay in maternity units have increased
midwifery workloads on the night shift. The level of assistance
provided by the core labour ward staff to the LMC midwife has
increased substantially.
Outcomes - As a consequence of this study, changes were made to
the night duty TrendCare maternity categories, additional acuity
indicators were developed and times for assisting LMC midwives in
labour ward increased. The updated TrendCare version was delivered
to maternity services in 2014.
Abstract: This paper presents a study of SIW circuits (Substrate
Integrated Waveguide) with a rigorous and fast original approach
based on Iterative process (WCIP). The theoretical suggested study is
validated by the simulation of two different examples of SIW
circuits. The obtained results are in good agreement with those of
measurement and with software HFSS.