Abstract: Residential block construction of big cities in China
began in the 1950s, and four models had far-reaching influence on
modern residential block in its development process, including unit
compound and residential district in 1950s to 1980s, and gated
community and open community in 1990s to now. Based on analysis
of the four models’ fabric, the article takes residential blocks in
Hangzhou west area as an example and carries on the studies from
urban structure level and block spacial level, mainly including urban
road network, land use, community function, road organization, public
space and building fabric. At last, the article puts forward “Semi-open
Sub-community” strategy to improve the current fabric.
Abstract: The Composite Shear Walls (CSW) with steel encased
profiles can be used as lateral-load resisting systems for buildings
that require considerable large lateral-load capacity. The aim of this
work is to propose the experimental work conducted on CSW having
L section folded plate (L shape steel made-up sections) as
longitudinal reinforcement in boundary regions. The study in this
paper present the experimental test conducted on CSW having L
section folded plate as longitudinal reinforcement in boundary
regions. The tested 1/3 geometric scaled CSW has aspect ratio of 3.2.
L-shape structural steel materials with 2L-19x57x7mm dimensions
were placed in shear wall boundary zones. The seismic behavior of
CSW test specimen was investigated by evaluating and interpreting
the hysteresis curves, envelope curves, rigidity and consumed energy
graphs of this tested element. In addition to this, the experimental
results, deformation and cracking patterns were evaluated, interpreted
and suggestions of the design recommendations were proposed.
Abstract: Currently there are many use of threaded reinforcing
bars in construction fields because those do not need additional screw
processing when connecting reinforcing bar by threaded coupler. In
this study, reinforced concrete bridge piers using threaded rebar
coupler system at the plastic hinge area were tested to evaluate seismic
performance. The test results showed that threads of the threaded rebar
coupler system could be loosened while under tension-compression
cyclic loading because tolerance and rib face angle of a threaded rebar
coupler system are greater than that of a conventional ribbed rebar
coupler system. As a result, cracks were concentrated just outside of
the mechanical coupler and stiffness of reinforced concrete bridge pier
decreased. Therefore, it is recommended that connection ratio of
mechanical couplers in one section shall be below 50% in order that
cracks are not concentrated just outside of the mechanical coupler.
Also, reduced stiffness of the specimen should be considered when
using the threaded rebar coupler system.
Abstract: Currently, green rating systems are mainly utilized for
correctly sizing mechanical and electrical systems, which have short
lifetime expectancies. In these systems, passive solar and bio-climatic
architecture, which have long lifetime expectancies, are neglected.
Urban rating systems consider buildings and services in addition to
neighborhoods and public transportation as integral parts of the built
environment. The main goal of this study was to develop a more
consistent point allocation system for urban building standards by
using six different lifetime shearing layers: Site, Structure, Skin,
Services, Space, and Stuff, each reflecting distinct environmental
damages. This shearing-layer concept was applied to internationally
well-known rating systems: Leadership in Energy and Environmental
Design (LEED) for Neighborhood Development, BRE
Environmental Assessment Method (BREEAM) for Communities
and Comprehensive Assessment System for Building Environmental
Efficiency (CASBEE) for Urban Development. The results showed
that LEED for Neighborhood Development and BREEAM for
Communities focused on long-lifetime-expectancy building designs,
whereas CASBEE for Urban Development gave equal importance to
the Building and Service Layers. Moreover, although this rating
system was applied using a building-scale assessment, “Urban Area +
Buildings” focuses on a short-lifetime-expectancy system design,
neglecting to improve the architectural design by considering bioclimatic
and passive solar aspects.
Abstract: Drying is a phenomenon that accompanies the
hardening of hydraulic materials. This study is concerned the
modelling of drying shrinkage of the hydraulic materials and the
prediction of the rate of spontaneous deformations of hydraulic
materials during hardening. The model developed takes consideration
of the main factors affecting drying shrinkage. There was agreement
between drying shrinkage predicted by the developed model and
experimental results. In last we show that developed model describe
the evolution of the drying shrinkage of high performances concretes
correctly.
Abstract: In addition to the advantages of light weight, resistant
corrosion and ease of processing, aluminum is also applied to the
long-span spatial structures. However, the elastic modulus of
aluminum is lower than that of the steel. This paper combines the
high performance aluminum honeycomb panel with the aluminum
latticed shell, forming a new panel-and-rod composite shell structure.
Through comparative analysis between the static and dynamic
performance, the conclusion that the structure of composite shell is
noticeably superior to the structure combined before.
Abstract: This paper presents a methodology for probabilistic
assessment of bearing capacity and prediction of failure mechanism
of masonry vaults at the ultimate state with consideration of the
natural variability of Young’s modulus of stones. First, the
computation model is explained. The failure mode corresponds to the
four-hinge mechanism. Based on this consideration, the study of a
vault composed of 16 segments is presented. The Young’s modulus of
the segments is considered as random variable defined by a mean
value and a coefficient of variation. A relationship linking the vault
bearing capacity to the voussoirs modulus variation is proposed. The
most probable failure mechanisms, in addition to that observed in the
deterministic case, are identified for each variability level as well as
their probability of occurrence. The results show that the mechanism
observed in the deterministic case has decreasing probability of
occurrence in terms of variability, while the number of other
mechanisms and their probability of occurrence increases with the
coefficient of variation of Young’s modulus. This means that if a
significant change in the Young’s modulus of the segments is proven,
taking it into account in computations becomes mandatory, both for
determining the vault bearing capacity and for predicting its failure
mechanism.
Abstract: Steel slag is a by-product of the steel industry and can
be used potentially as aggregate in the asphalt mixture. This study
evaluates the use of Steel Slag Aggregates (SSA) as a substitute for
natural aggregates in the production of hot mix asphalt (HMA) for
road construction. Based on intensive laboratory testing program, the
characteristic properties of SSA were assessed to determine its
suitability to be used in HMA. Four different percentages (0, 50, 75,
and 100%) of SSA were used, and the proposed mix designs for
HMA were conducted in accordance with Marshall mix design. The
experiment results revealed that the addition of SSA has a significant
improvement on the properties of HMA. An increase in density and
stability and a reduction in flow and air voids values were clearly
observed in specimens prepared with 100% SSA. It is concluded that
the steel slag can be considered reasonable alternative source of
aggregate for concrete asphalt mixture production.
Abstract: The objective of this paper is to evaluate the effects of
soil-structure interaction (SSI) on the modal characteristics and on
the dynamic response of current structures. The objective is on the
overall behaviour of a real structure of five storeys reinforced
concrete (R/C) building typically encountered in Algeria. Sensitivity
studies are undertaken in order to study the effects of frequency
content of the input motion, frequency of the soil-structure system,
rigidity and depth of the soil layer on the dynamic response of such
structures. This investigation indicated that the rigidity of the soil
layer is the predominant factor in soil-structure interaction and its
increases would definitely reduce the deformation in the R/C
structure. On the other hand, increasing the period of the underlying
soil will cause an increase in the lateral displacements at story levels
and create irregularity in the distribution of story shears. Possible
resonance between the frequency content of the input motion and soil
could also play an important role in increasing the structural
response.
Abstract: Sewer deposits have been identified as a major cause
of dysfunctions in combined sewer systems regarding sewer
management, which induces different negative consequents resulting
in poor hydraulic conveyance, environmental damages as well as
worker’s health. In order to overcome the problematics of
sedimentation, flushing has been considered as the most operative
and cost-effective way to minimize the sediments impacts and
prevent such challenges. Flushing, by prompting turbulent wave
effects, can modify the bed form depending on the hydraulic
properties and geometrical characteristics of the conduit. So far, the
dynamics of the bed-load during high-flow events in combined sewer
systems as a complex environment is not well understood, mostly due
to lack of measuring devices capable to work in the “hostile” in
combined sewer system correctly. In this regards, a one-episode
flushing issue from an opening gate valve with weir function was
carried out in a trunk sewer in Paris to understand its cleansing
efficiency on the sediments (thickness: 0-30 cm). During more than
1h of flushing within 5 m distance in downstream of this flushing
device, a maximum flowrate and a maximum level of water have
been recorded at 5 m in downstream of the gate as 4.1 m3/s and 2.1
m respectively. This paper is aimed to evaluate the efficiency of this
type of gate for around 1.1 km (from the point -50 m to +1050 m in
downstream from the gate) by (i) determining bed grain-size
distribution and sediments evolution through the sewer channel, as
well as their organic matter content, and (ii) identifying sections that
exhibit more changes in their texture after the flush. For the first one,
two series of sampling were taken from the sewer length and then
analyzed in laboratory, one before flushing and second after, at same
points among the sewer channel. Hence, a non-intrusive sampling
instrument has undertaken to extract the sediments smaller than the
fine gravels. The comparison between sediments texture after the
flush operation and the initial state, revealed the most modified zones
by the flush effect, regarding the sewer invert slope and hydraulic
parameters in the zone up to 400 m from the gate. At this distance,
despite the increase of sediment grain-size rages, D50 (median grainsize)
varies between 0.6 mm and 1.1 mm compared to 0.8 mm and 10
mm before and after flushing, respectively. Overall, regarding the
sewer channel invert slope, results indicate that grains smaller than
sands (< 2 mm) are more transported to downstream along about 400
m from the gate: in average 69% before against 38% after the flush
with more dispersion of grain-sizes distributions. Furthermore, high
effect of the channel bed irregularities on the bed material evolution
has been observed after the flush.
Abstract: Twin steel plates-concrete composite shear walls are
composed of a pair of steel plate layers and a concrete layer
sandwiched between them, which have the characteristics of both
reinforced concrete shear walls and steel plate shear walls. Twin steel
plates-composite shear walls contain very high ultimsate bearing
capacity and ductility, which have great potential to be applied in the
super high-rise buildings and special structures. In this paper, we
analyzed the basic characteristics and stress mechanism of the twin
steel plates-composite shear walls. Specifically, we analyzed the
effects of the steel plate thickness, wall thickness and concrete
strength on the bearing capacity of the twin steel plates-composite
shear walls. The analysis results indicate that: (1) the initial shear
stiffness and ultimate shear-carrying capacity is not significantly
affected by the thickness of concrete wall but by the class of concrete,
(2) both factors significantly impact the shear distribution of the
shear walls in ultimate shear-carrying capacity. The technique of twin
steel plates-composite shear walls has been successfully applied in
the construction of an 88-meter Huge Statue of Buddha located in
Hunan Province, China. The analysis results and engineering
experiences showed that the twin steel plates-composite shear walls
have great potential for future research and applications.
Abstract: Concrete is strong in compression however weak in
tension. The tensile strength as well as ductile property of concrete
could be improved by addition of short dispersed fibers. Polyethylene
terephthalate (PET) fiber obtained from hand cutting or mechanical
slitting of plastic sheets generally used as discrete reinforcement in
substitution of steel fiber. PET fiber obtained from the former process
is in the form of straight slit sheet pattern that impart weaker
mechanical bonding behavior in the concrete matrix. To improve the
limitation of straight slit sheet fiber the present study considered two
additional geometry of fiber namely (a) flattened end slit sheet and
(b) deformed slit sheet. The mix for plain concrete was design for a
compressive strength of 25 MPa at 28 days curing time with a watercement
ratio of 0.5. Cylindrical and beam specimens with 0.5% fibers
volume fraction and without fibers were cast to investigate the
influence of geometry on the mechanical properties of concrete. The
performance parameters mainly studied include flexural strength,
splitting tensile strength, compressive strength and ultrasonic pulse
velocity (UPV). Test results show that geometry of fiber has a
marginal effect on the workability of concrete. However, it plays a
significant role in achieving a good compressive and tensile strength
of concrete. Further, significant improvement in term of flexural and
energy dissipation capacity were observed from other fibers as
compared to the straight slit sheet pattern. Also, the inclusion of PET
fiber improved the ability in absorbing energy in the post-cracking
state of the specimen as well as no significant porous structures.
Abstract: Investigating the dynamic responses of high rise
structures under the effect of siesmic ground motion is extremely
important for the proper analysis and design of multitoried structures.
Since the presence of infilled walls strongly influences the behaviour
of frame systems in multistoried buildings, there is an increased need
for developing guidelines for the analysis and design of infilled
frames under the effect of dynamic loads for safe and proper design
of buildings. In this manuscript, we evaluate the natural frequencies
and natural periods of single bay single storey frames considering the
effect of infill walls by using the Eigen value analysis and validating
with SAP 2000 (free vibration analysis). Various parameters obtained
from the diagonal strut model followed for the free vibration analysis
is then compared with the Finite Element model, where infill is
modeled as shell elements (four noded). We also evaluated the effect
of various parameters on the natural periods of vibration obtained by
free vibration analysis in SAP 2000 comparing them with those
obtained by the empirical expressions presented in I.S. 1893(Part I)-
2002.
Abstract: In this paper, relationship between different properties
of IC concrete and water cement ratio, obtained from a
comprehensive experiment conducted on IC using local materials
(Burnt clay chips- BC) is presented. In addition, saturated SAP was
used as an IC material in some cases. Relationships have been
developed through regression analysis. The focus of this analysis is
on developing relationship between a dependent variable and an
independent variable. Different percent replacements of BC and
water cement ratios were used. Compressive strength, modulus of
elasticity, water permeability and chloride permeability were tested
and variations of these parameters were analyzed with respect to
water cement ratio.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: The properties of hollow sandcrete blocks produced in
Minna, Nigeria are presented. Sandcrete block is made of cement,
water and sand binded together in certain mix proportions. For the
purpose of this work, fifty (50) commercial sandcrete block industries
were visited in Minna, Nigeria to obtain block samples and
aggregates used for the manufacture, and to take inventory of the mix
composition and the production process. Sieve analysis tests were
conduction on the soil sample from various block industries to
ascertain their quality to be used for block making. The mix ratios
were also investigated. Five (5) nine inches (9’’ or 225mm) blocks
were obtained from each block industry and tested for dimensional
compliance and compressive strength. The results of the soil test
shows that the grading fall within the limit for natural aggregate and
can easily are used to obtain workable mix. Physical examinations of
the block sizes show slight deviation from the standard requirement
in NIS 87:2000. Compressive strength of hollow sandcrete blocks in
range of 0.12 N/mm2 to 0.54 N/mm2 was obtained which is below the
recommendable value of 3.45 N/mm2 for load bearing hollow
sandcrete blocks. This indicates that these blocks are below the
standard for load-bearing sandcrete blocks and cannot be used as load
bearing walling units. The mix composition also indicated low
cement content resulting in low compressive strength. Most of the
commercial block industries visited does not take curing very serious.
Water were only sprinkled ones or twice before the blocks were
stacked and made readily available for sale. It is recommended that a
mix ratio of 1:4 to 1:6 should be used for the production of sandcrete
blocks and proper curing practice should be adhered. Blocks should
also be cured for 14 days before making them available for
consumers.
Abstract: Fiber Reinforced Polymer (FRP) is a composite material with exceptional properties that are capable to replace conventional steel reinforcement in reinforced and pre-stressed concrete structures. However, the main obstacle for their wide use in pre-stressed concrete application is the anchorage system. Due to the weakness of FRP in the transverse direction, the pre-stressing capacity of FRP bars are limited. This paper investigates the modification of the conventional wedge anchorage system to be used for stressing of FRP bars in pre-stressed applications. Epoxy adhesive material with glass FRP (GFRP) bars and conventional steel wedge were used in this paper. The GFRP bars are encased with epoxy at the anchor zone and the wedge system was used in pull-out test. The results showed a loading capacity of 47.6 kN which is 69% of the bar ultimate capacity. Additionally, nylon wedge was made with the same dimensions of the steel wedge and tested for GFRP bars without epoxy layer. The nylon wedge showed a loading capacity of 19.7 kN which is only 28.5% of the ultimate bar capacity.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear dynamics
analysis of the structures with assuming elastic-perfectly-plastic
behavior was performed using RAM PERFORM-3D software; the
horizontal component was taken into consideration with and without
the incorporation of the corresponding vertical component. Dynamic
responses obtained for the horizontal component acting alone were
compared with those obtained from the simultaneous application of
both seismic components. The results show that the effect of the
vertical component of ground motion may increase the axial load
significantly in the interior columns and, consequently, the stories.
The plastic mechanisms would be changed. The P-Delta effect is
expected to increase. The punching base plate shear of the columns
should be considered. Moreover, the vertical component increases the
input energy when the structures exhibit inelastic behavior and are
taller.
Abstract: In this study, an Artificial Neural Network (ANN)
analytical method has been developed for analyzing earthquake
performances of the Reinforced Concrete (RC) buildings. 66 RC
buildings with four to ten storeys were subjected to performance
analysis according to the parameters which are the existing material,
loading and geometrical characteristics of the buildings. The selected
parameters have been thought to be effective on the performance of
RC buildings. In the performance analyses stage of the study, level of
performance possible to be shown by these buildings in case of an
earthquake was determined on the basis of the 4-grade performance
levels specified in Turkish Earthquake Code-2007 (TEC-2007). After
obtaining the 4-grade performance level, selected 23 parameters of
each building have been matched with the performance level. In this
stage, ANN-based fast evaluation algorithm mentioned above made
an economic and rapid evaluation of four to ten storey RC buildings.
According to the study, the prediction accuracy of ANN has been
found about 74%.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.