Abstract: The aim of this study is to test the feasibility of SIPINA method to predict the harmfulness parameters controlling the seismic response. The approach developed takes into consideration both the focal depth and the peak ground acceleration. The parameter to determine is displacement. The data used for the learning of this method and analysis nonlinear seismic are described and applied to a class of models damaged to some typical structures of the existing urban infrastructure of Jassy, Romania. The results obtained indicate an influence of the focal depth and the peak ground acceleration on the displacement.
Abstract: Structural vibration means repetitive motion that causes fatigue and reduction of the performance of a structure. An earthquake may release high amount of energy that can have adverse effect on all components of a structure. Therefore, decreasing of vibration or maintaining performance of structures such as bridges, dams, roads and buildings is important for life safety and reducing economic loss. When earthquake or any vibration happens, investigation on parts of a structure which sustain the seismic loads is mandatory to provide a safe condition for the occupants. One of the solutions for reducing the earthquake vibration in a structure is using of vibration control devices such as dampers and base isolators. The objective of this study is to investigate the optimal positions of friction dampers and base isolators for better seismic response of 2D frame. For this purpose, a two bay and six story frame with different distribution formats was modeled and some of their responses to earthquake such as inter-story drift, max joint displacement, max axial force and max bending moment were determined and compared using non-linear dynamic analysis.
Abstract: The performance of multiple tuned mass dampers to
mitigate the seismic vibration of structures considering real time
history data is investigated in this paper. Three different real
earthquake time history data like Kobe, Imperial Valley and
Mammoth Lake are taken in the present study. The multiple tuned
mass dampers (MTMD) are distributed at each storey. For
comparative study, single tuned mass damper (STMD) is installed at
top of the similar structure. This study is conducted for a fixed mass
ratio (5%) and fixed damping ratio (5%) of structures. Numerical
study is performed to evaluate the effectiveness of MTMDs and
overall system performance. The displacement, acceleration, base
shear and storey drift are obtained for both combined system
(structure with MTMD and structure with STMD) for all earthquakes.
The same responses are also obtained for structure without damper
system. From obtained results, it is investigated that the MTMD
configuration is more effective for controlling the seismic response of
the primary system with compare to STMD configuration.
Abstract: The seismic responses-based structural health monitoring system has been performed to prevent seismic damage. Structural seismic damage of building is caused by the instantaneous stress concentration which is related with dynamic characteristic of earthquake. Meanwhile, seismic response analysis to estimate the dynamic responses of building demands significantly high computational cost. To prevent the failure of structural members from the characteristic of the earthquake and the significantly high computational cost for seismic response analysis, this paper presents an artificial neural network (ANN) based prediction model for dynamic responses of building considering specific time length. Through the measured dynamic responses, input and output node of the ANN are formed by the length of specific time, and adopted for the training. In the model, evolutionary radial basis function neural network (ERBFNN), that radial basis function network (RBFN) is integrated with evolutionary optimization algorithm to find variables in RBF, is implemented. The effectiveness of the proposed model is verified through an analytical study applying responses from dynamic analysis for multi-degree of freedom system to training data in ERBFNN.
Abstract: In this study, the time-dependent behavior of damaged
reinforced concrete shear wall structures strengthened with composite
plates having variable fibers spacing was investigated to analyze their
seismic response. In the analytical formulation, the adherent and the
adhesive layers are all modeled as shear walls, using the mixed Finite
Element Method (FEM). The anisotropic damage model is adopted to
describe the damage extent of the Reinforced Concrete shear walls.
The phenomenon of creep and shrinkage of concrete has been
determined by Eurocode 2. Large earthquakes recorded in Algeria
(El-Asnam and Boumerdes) have been tested to demonstrate the
accuracy of the proposed method. Numerical results are obtained for non-uniform distributions of
carbon fibers in epoxy matrices. The effects of damage extent and the
delay mechanism creep and shrinkage of concrete are highlighted.
Prospects are being studied.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: This study, tries to suggest a design method based on
displacement using finite difference numerical modeling in
reinforcing soil retaining wall with steel strip. In this case, dynamic
loading characteristics such as duration, frequency, peak ground
acceleration, geometrical characteristics of reinforced soil structure
and type of the site are considered to correct the pseudo static method
and finally introduce the pseudo static coefficient as a function of
seismic performance level and peak ground acceleration. For this
purpose, the influence of dynamic loading characteristics,
reinforcement length, height of reinforced system and type of the site
are investigated on seismic behavior of reinforcing soil retaining wall
with steel strip. Numerical results illustrate that the seismic response
of this type of wall is highly dependent to cumulative absolute
velocity, maximum acceleration, and height and reinforcement length
so that the reinforcement length can be introduced as the main factor
in shape of failure. Considering the loading parameters, geometric parameters of the
wall and type of the site showed that the used method in this study
leads to efficient designs in comparison with other methods, which
are usually based on limit-equilibrium concept. The outputs show the
over-estimation of equilibrium design methods in comparison with
proposed displacement based methods here.
Abstract: Environmental and functional conditions, sometimes,
necessitate the architectural plan of the building to be asymmetric,
and this result in an asymmetric structure. In such cases finding an
optimal pattern for locating the components of lateral load bearing
system, including shear walls, in the building’s plan is desired. In
case of shear wall in addition to the location the shape of the wall
cross-section is also an effective factor. Various types of shear walls
and their proper layout might come effective in better stiffness
distribution and more appropriate seismic response of the building.
Several studies have been conducted in the context of analysis and
design of shear walls; however, few studies have been performed on
making decisions for the location and form of shear walls in multistory
buildings, especially those with irregular plan. In this study, an
attempt has been made to obtain the most reliable seismic behavior of
multi-story reinforced concrete vertically chamfered buildings by
using more appropriate shear walls form and arrangement in 7-, 10-,
12-, and 15-stoy buildings. The considered forms and arrangements
include common rectangular walls and L-, T-, U- and Z-shaped plan,
located as the core or in the outer frames of the building structure.
Comparison of seismic behaviors of the buildings, including
maximum roof displacement and particularly formation of plastic
hinges and their distribution in the buildings’ structures, have been
done based on the results of a series of nonlinear time history
analyses, by using a set of selected earthquake records. Results show
that shear walls with U-shaped cross-section, placed as the building
central core, and also walls with Z-shaped cross-section, placed at the
corners give the building more reliable seismic behavior.
Abstract: Damage status of RC buildings is greatly influenced
by the characteristics of the imposed ground motion. Peak Ground
Acceleration and frequency contents are considered the main two
factors that affect ground motion characteristics; hence, affecting the
seismic response of RC structures and consequently their damage
state. A detailed investigation on the combined effects of these two
factors on damage assessment of RC buildings is carried out. Twenty
one earthquake records are analyzed and arranged into three groups,
according to their frequency contents. These records are used in an
investigation to define the expected damage state that would be
attained by RC buildings, if subjected to varying ground motion
characteristics. The damage assessment is conducted through
examining drift ratios and damage indices of the overall structure and
the significant structural components of RC building. Base and story
shear of RC building model, are also investigated, for cases when the
model is subjected to the chosen twenty one earthquake records.
Nonlinear dynamic analyses are performed on a 2-dimensional model
of a 12-story RC building.
Abstract: The present research work investigates the seismic
response of reinforced concrete (RC) frame building considering the
effect of modeling masonry infill (MI) walls. The seismic behavior of
a residential 6-storey RC frame building, considering and ignoring
the effect of masonry, is numerically investigated using response
spectrum (RS) analysis. The considered herein building is designed
as a moment resisting frame (MRF) system following the Egyptian
code (EC) requirements. Two developed models in terms of bare
frame and infill walls frame are used in the study. Equivalent
diagonal strut methodology is used to represent the behavior of infill
walls, whilst the well-known software package ETABS is used for
implementing all frame models and performing the analysis. The
results of the numerical simulations such as base shear,
displacements, and internal forces for the bare frame as well as the
infill wall frame are presented in a comparative way. The results of
the study indicate that the interaction between infill walls and frames
significantly change the responses of buildings during earthquakes
compared to the results of bare frame building model. Specifically,
the seismic analysis of RC bare frame structure leads to
underestimation of base shear and consequently damage or even
collapse of buildings may occur under strong shakings. On the other
hand, considering infill walls significantly decrease the peak floor
displacements and drifts in both X and Y-directions.
Abstract: The seismic responses of steel buildings with semirigid
post-tensioned connections (PC) are estimated and compared
with those of steel buildings with typical rigid (welded) connections
(RC). The comparison is made in terms of global and local response
parameters. The results indicate that the seismic responses in terms of
interstory shears, roof displacements, axial load and bending
moments are smaller for the buildings with PC connection. The
difference is larger for global than for local parameters, which in turn
varies from one column location to another. The reason for this
improved behavior is that the buildings with PC dissipate more
hysteretic energy than those with RC. In addition, unlike the case of
buildings with WC, for the PC structures the hysteretic energy is
mostly dissipated at the connections, which implies that structural
damage in beams and columns is not significant. According to these
results, steel buildings with PC are a viable option in high seismicity
areas because of their smaller response and self-centering connection
capacity as well as the fact that brittle failure is avoided.
Abstract: A capacity spectrum method (CSM), one of methodologies to evaluate seismic fragilities of building structures, has been long recognized as the most convenient method, even if it contains several limitations to predict the seismic response of structures of interest. This paper proposes the procedure to estimate seismic fragility curves using an incremental dynamic analysis (IDA) rather than the method adopting a CSM. To achieve the research purpose, this study compares the seismic fragility curves of a 5-story reinforced concrete (RC) moment frame obtained from both methods; an IDA method and aCSM. Both seismic fragility curves are similar in slight and moderate damage states whereas the fragility curve obtained from the IDA method presents less variation (or uncertainties) in extensive and complete damage states. This is due to the fact that the IDA method can properly capture the structural response beyond yielding rather than the CSM and can directly calculate higher mode effects. From these observations, the CSM could overestimate seismic vulnerabilities of the studied structure in extensive or complete damage states.
Abstract: There are many researches on parameters affecting seismic behavior of steel moment frames. Great deal of these researches considers cover plate connections with or without haunch and direct beam to column connection for exterior columns. Also there are experimental results for interior connections with equal beam depth on both sides but not much research has been performed on the seismic behavior of joints with unequal beam depth. Based on previous experimental results, a series of companion analyses have been set up considering different beam height and connection detailing configuration to investigate the seismic behavior of the connections. Results of this study indicate that when the differences between beams height on both side increases, use of haunch connection system leads to significant improvement in the seismic response whereas other configurations did not provide satisfying results.
Abstract: Concentric bracing systems have been in practice for many years because of their effectiveness in reducing seismic response. Depending on concept, seismic design codes provide various response modification factors (R), which itself consists of different terms, for different types of lateral load bearing systems but configuration of these systems are often ignored in the proposed values. This study aims at considering the effect of different x-bracing diagonal configuration on values of ductility dependent term in R computation. 51 models were created and nonlinear push over analysis has been performed. The main variables of this study were the suitable location of X–bracing diagonal configurations, which establishes better nonlinear behavior in concentric braced steel frames. Results show that some x-bracing diagonal configurations improve the seismic performance of CBF significantly and explicit consideration of lateral load bearing systems seems necessary.
Abstract: The modern energy-efficient houses are often founded on a thermal insulation (TI) layer placed under the building’s RC foundation slab.The purpose of the paper is to identify the potential problems of the buildings founded on TI layer from the seismic point of view. The two main goals of the study were to assess the seismic behavior of such buildings, and to search for the critical structural parameters affecting the response of the superstructure as well as of the extruded polystyrene (XPS) layer. As a test building a multi-storeyed RC frame structure with and without the XPS layer under the foundation slab has been investigated utilizing nonlinear dynamic (time-history) and static (pushover) analyses. The structural response has been investigated with reference to the following performance parameters: i) Building’s lateral roof displacements, ii) Edge compressive and shear strains of the XPS, iii) Horizontal accelerations of the superstructure, iv) Plastic hinge patterns of the superstructure, v) Part of the foundation in compression, and vi) Deformations of the underlying soil and vertical displacements of the foundation slab (i.e. identifying the potential uplift). The results have shown that in the case of higher and stiff structures lying on firm soil the use of XPS under the foundation slab might induce amplified structural peak responses compared to the building models without XPS under the foundation slab. The analysis has revealed that the superstructure as well as the XPS response is substantially affected by the stiffness of the foundation slab.
Abstract: Building code-related literature provides
recommendations on normalizing approaches to the calculation of
the dynamic properties of structures. Most building codes make a
distinction among types of structural systems, construction material,
and configuration through a numerical coefficient in the
expression for the fundamental period. The period is then used in
normalized response spectra to compute base shear. The typical
parameter used in simplified code formulas for the fundamental
period is overall building height raised to a power determined from
analytical and experimental results. However, reinforced concrete
buildings which constitute the majority of built space in less
developed countries pose additional challenges to the ones built with
homogeneous material such as steel, or with concrete under stricter
quality control. In the present paper, the particularities of reinforced
concrete buildings are explored and related to current methods of
equivalent static analysis. A comparative study is presented between
the Uniform Building Code, commonly used for buildings within
and outside the USA, and data from the Middle East used to model
151 reinforced concrete buildings of varying number of bays, number
of floors, overall building height, and individual story height. The
fundamental period was calculated using eigenvalue matrix
computation. The results were also used in a separate regression
analysis where the computed period serves as dependent variable,
while five building properties serve as independent variables. The
statistical analysis shed light on important parameters that simplified
code formulas need to account for including individual story height,
overall building height, floor plan, number of bays, and concrete
properties. Such inclusions are important for reinforced concrete
buildings of special conditions due to the level of concrete damage,
aging, or materials quality control during construction.
Overall results of the present analysis show that simplified code
formulas for fundamental period and base shear may be applied but
they require revisions to account for multiple parameters. The
conclusion above is confirmed by the analytical model where
fundamental periods were computed using numerical techniques and
eigenvalue solutions. This recommendation is particularly relevant
to code upgrades in less developed countries where it is customary to
adopt, and mildly adapt international codes.
We also note the necessity of further research using empirical data
from buildings in Lebanon that were subjected to severe damage due
to impulse loading or accelerated aging. However, we excluded this
study from the present paper and left it for future research as it has its
own peculiarities and requires a different type of analysis.
Abstract: A scheme integrated with deterministic–stochastic subspace system identification and the method of damage localization vector is proposed in this study for damage detection of structures based on seismic response data. A series of shaking table tests using a five-storey steel frame has been conducted in National Center for Research on Earthquake Engineering (NCREE), Taiwan. Damage condition is simulated by reducing the cross-sectional area of some of the columns at the bottom. Both single and combinations of multiple damage conditions at various locations have been considered. In the system identification analysis, either full or partial observation conditions have been taken into account. It has been shown that the damaged stories can be identified from global responses of the structure to earthquakes if sufficiently observed. In addition to detecting damage(s) with respect to the intact structure, identification of new or extended damages of the as-damaged (ill-conditioned) counterpart has also been studied. The proposed scheme proves to be effective.
Abstract: Recently, an increasing trend of passive and low-energy buildings transferring form non earthquake-prone to earthquake-prone regions has thrown out the question about the seismic safety of such buildings. The paper describes the most commonly used thermal insulating materials and the special details, which could be critical from the point of view of earthquake resistance. The most critical appeared to be the cases of buildings founded on the RC foundation slab lying on a thermal insulation (TI) layer made of extruded polystyrene (XPS). It was pointed out that in such cases the seismic response of such buildings might differ to response of their fixed based counterparts. The main parameters that need special designers’ attention are: the building’s lateral top displacement, the ductility demand of the superstructure, the foundation friction coefficient demand, the maximum compressive stress in the TI layer and the percentage of the uplifted foundation. The analyses have shown that the potentially negative influences of inserting the TI under the foundation slab could be expected only for slender high-rise buildings subjected to severe earthquakes. Oppositely it was demonstrated for the foundation friction coefficient demand which could exceed the capacity value yet in the case of low-rise buildings subjected to moderate earthquakes. Some suggestions to prevent the horizontal shifts are also given.
Abstract: Steel bracing members are widely used in steel
structures to reduce lateral displacement and dissipate energy during
earthquake motions. Concentric steel bracing provide an excellent
approach for strengthening and stiffening steel buildings. Using these
braces the designer can hardly adjust the stiffness together with
ductility as needed because of buckling of braces in compression. In
this study the use of SMA bracing and steel bracing (Mega) utilized
in steel frames are investigated. The effectiveness of these two
systems in rehabilitating a mid-rise eight-storey steel frames were
examined using time-history nonlinear analysis utilizing seismostruct
software. Results show that both systems improve the strength and
stiffness of the original structure but due to excellent behavior of
SMA in nonlinear phase and under compressive forces this system
shows much better performance than the rehabilitation system of
Mega bracing.
Abstract: A multi-panel PMC infilled system, using polymer matrix composite (PMC) material, was introduced as new conceptual design for seismic retrofitting. A proposed multi panel PMC infilled system was composed of two basic structural components: inner PMC sandwich infills and outer FRP damping panels. The PMC material had high stiffness-to-weight and strength-to-weight ratios. Therefore, the addition of PMC infill panels into existing structures would not significantly alter the weight of the structure, while providing substantial structural enhancement.
In this study, an equivalent linearized dynamic analysis for a proposed multi-panel PMC infilled frame was performed, in order to assess their effectiveness and their responses under the simulated earthquake loading. Upon comparing undamped (without PMC panel) and damped (with PMC panel) structures, numerical results showed that structural damping with passive interface damping layer could significantly enhance the seismic response.