Abstract: This paper focuses on parametric analysis of reinforced concrete structures equipped with supplemental damping braces. Practitioners still luck sufficient data for current design of damper added structures and often reduce the real model to a pure damper braced structure even if this assumption is neither realistic nor conservative. In the present study, the damping brace is modelled as made by a linear supporting brace connected in series with the viscous/hysteretic damper. Deformation capacity of existing structures is usually not adequate to undergo the design earthquake. In spite of this, additional dampers could be introduced strongly limiting structural damage to acceptable values, or in some cases, reducing frame response to elastic behavior. This work is aimed at providing useful considerations for retrofit of existing buildings by means of supplemental damping braces. The study explicitly takes into consideration variability of (a) relative frame to supporting brace stiffness, (b) dampers’ coefficient (viscous coefficient or yielding force) and (c) non-linear frame behavior. Non-linear time history analysis has been run to account for both dampers’ behavior and non-linear plastic hinges modelled by Pivot hysteretic type. Parametric analysis based on previous studies on SDOF or MDOF linear frames provide reference values for nearly optimal damping systems design. With respect to bare frame configuration, seismic response of the damper-added frame is strongly improved, limiting deformations to acceptable values far below ultimate capacity. Results of the analysis also demonstrated the beneficial effect of stiffer supporting braces, thus highlighting inadequacy of simplified pure damper models. At the same time, the effect of variable damping coefficient and yielding force has to be treated as an optimization problem.
Abstract: The present research work investigates the seismic
response of reinforced concrete (RC) frame building considering the
effect of modeling masonry infill (MI) walls. The seismic behavior of
a residential 6-storey RC frame building, considering and ignoring
the effect of masonry, is numerically investigated using response
spectrum (RS) analysis. The considered herein building is designed
as a moment resisting frame (MRF) system following the Egyptian
code (EC) requirements. Two developed models in terms of bare
frame and infill walls frame are used in the study. Equivalent
diagonal strut methodology is used to represent the behavior of infill
walls, whilst the well-known software package ETABS is used for
implementing all frame models and performing the analysis. The
results of the numerical simulations such as base shear,
displacements, and internal forces for the bare frame as well as the
infill wall frame are presented in a comparative way. The results of
the study indicate that the interaction between infill walls and frames
significantly change the responses of buildings during earthquakes
compared to the results of bare frame building model. Specifically,
the seismic analysis of RC bare frame structure leads to
underestimation of base shear and consequently damage or even
collapse of buildings may occur under strong shakings. On the other
hand, considering infill walls significantly decrease the peak floor
displacements and drifts in both X and Y-directions.