Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: The paper presents a plastic analysis procedure based
on the energy balance concept for performance based seismic retrofit
of multi-story multi-bay masonry infilled reinforced concrete (R/C)
frames with a ‘soft’ ground story using passive energy dissipation
(PED) devices with the objective of achieving a target performance
level of the retrofitted R/C frame for a given seismic hazard level at
the building site. The proposed energy based plastic analysis
procedure was employed for developing performance based design
(PBD) formulations for PED devices for a simulated application in
seismic retrofit of existing frame structures designed in compliance
with the prevalent standard codes of practice. The PBD formulations
developed for PED devices were implemented for simulated seismic
retrofit of a representative code-compliant masonry infilled R/C
frame with a ‘soft’ ground story using friction dampers as the PED
device. Non-linear dynamic analyses of the retrofitted masonry
infilled R/C frames is performed to investigate the efficacy and
accuracy of the proposed energy based plastic analysis procedure in
achieving the target performance level under design level
earthquakes. Results of non-linear dynamic analyses demonstrate that
the maximum inter-story drifts in the masonry infilled R/C frames
with a ‘soft’ ground story that is retrofitted with the friction dampers
designed using the proposed PBD formulations are controlled within
the target drifts under near-field as well far-field earthquakes.
Abstract: Performance based design (PBD) is an iterative exercise in which a preliminary trial design of the building structure is selected and if the selected trial design of the building structure does not conform to the desired performance objective, the trial design is revised. In this context, development of a fundamental approach for performance based seismic design of masonry infilled frames with minimum number of trials is an important objective. The paper presents a plastic design procedure based on the energy balance concept for PBD of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames subjected to near-field earthquakes. The proposed energy based plastic design procedure was implemented for trial performance based seismic design of representative masonry infilled reinforced concrete frames with various practically relevant distributions of masonry infill panels over the frame elevation. Non-linear dynamic analyses of the trial PBD of masonry infilled R/C frames was performed under the action of near-field earthquake ground motions. The results of non-linear dynamic analyses demonstrate that the proposed energy method is effective for performance based design of masonry infilled R/C frames under near-field as well as far-field earthquakes.