Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: Performance based design (PBD) is an iterative exercise in which a preliminary trial design of the building structure is selected and if the selected trial design of the building structure does not conform to the desired performance objective, the trial design is revised. In this context, development of a fundamental approach for performance based seismic design of masonry infilled frames with minimum number of trials is an important objective. The paper presents a plastic design procedure based on the energy balance concept for PBD of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames subjected to near-field earthquakes. The proposed energy based plastic design procedure was implemented for trial performance based seismic design of representative masonry infilled reinforced concrete frames with various practically relevant distributions of masonry infill panels over the frame elevation. Non-linear dynamic analyses of the trial PBD of masonry infilled R/C frames was performed under the action of near-field earthquake ground motions. The results of non-linear dynamic analyses demonstrate that the proposed energy method is effective for performance based design of masonry infilled R/C frames under near-field as well as far-field earthquakes.