Vibration Control of Building Using Multiple Tuned Mass Dampers Considering Real Earthquake Time History

The performance of multiple tuned mass dampers to
mitigate the seismic vibration of structures considering real time
history data is investigated in this paper. Three different real
earthquake time history data like Kobe, Imperial Valley and
Mammoth Lake are taken in the present study. The multiple tuned
mass dampers (MTMD) are distributed at each storey. For
comparative study, single tuned mass damper (STMD) is installed at
top of the similar structure. This study is conducted for a fixed mass
ratio (5%) and fixed damping ratio (5%) of structures. Numerical
study is performed to evaluate the effectiveness of MTMDs and
overall system performance. The displacement, acceleration, base
shear and storey drift are obtained for both combined system
(structure with MTMD and structure with STMD) for all earthquakes.
The same responses are also obtained for structure without damper
system. From obtained results, it is investigated that the MTMD
configuration is more effective for controlling the seismic response of
the primary system with compare to STMD configuration.




References:
[1] L. A. Bergman, D. M. McFarland, J.K. Hall, E.A. Johnson, and A. Kareem, “Optimal distribution of tuned-mass dampers in wind sensitive structures.” Proc., 5th Int. Comf. On Struct. Safety and Reliability, (ICOSSAR), ASCE, New York, NY, 1989.
[2] L. A. Bergman, D.M. McFarland, and A. Kareem, “Coupled passive control of tall buildings”, Struct. Abstracts, ASCE, New York, NY, 1991.
[3] K. Xu, and T. Igusa, “Dynamic Characteristics of Multiple Substructures with closely Spaced Frequencies,” Earthquake Eng. Struct. Dyn., 1992, 21(12), 1059-1070.
[4] T. Igusa, and K. Xu, “Vibration control using multiple tuned mass dampers” J. sound vibra., 1994, v175,491-503.
[5] H. Yamaguchi, and N. Harnpornchai, “Fundamental characteristics of multiple tuned madd dampers for suppressing harmonically forced oscillations”, Earthq. Engng. Struct. Dyn., 1993, 22, 51-62.
[6] A. Kareem, and S. Kline, “Performance of Multiple Mass Dampers under Random Loading,” J. Struct. Eng., 1995, 121(2), 348-361.
[7] R. Janjid, “Dynamic characteristic of structures with multiple tuned mass dampers” Struct. Engng. Mech. 1995, 3,497-509.
[8] T. A. Sakr, “Vibration control of buildings by using partial floor loads as multiple tuned mass dampers”, Housing and Building National Research Center, 2015.
[9] O. Levan, and Y. Daniel, “Allocation and sizing of multiple tuned mass dampers for seismic control of irregular structures”, Geotechnical, Geological and Earthquake Engineering, 2013, 24,328-338.
[10] K. C. S. Kowk, and B Samali, “Performance of tuned mass dampers under wind loads”, Engineering Structures, 1995, 17, 655-67.
[11] F. Sadek, B. Mohraz, A. W. Taylor, and R. M. Chung, “A method of estimating the parameters of tuned mass dampers for seismic applications”, Earthquake Engineering and Structural Dynamics, 1997 26, 617-635.
[12] L. Zuo, and S. A. Nayfeh, “Optimization of the Individual Stiffness and Damping Parameters in Multiple-Tuned Mass-Damper Systems”, vibration and acoustics, 2005 127, 77-83.
[13] J. P.Denhartog, Mechanical Vibration, McGraw-Hill, New York, 1947.
[14] G. B. Warburton, “Optimum absorber parameters for various combinations of response and excitation parameters”. Earthquake Engineering and Structural Dynamics, 1982, 10, 381–401.