Abstract: This study presents the effect of prefabricated vertical drain system properties on embankment behavior by calculating the settlement, lateral displacement and induced excess pore pressure by numerical method. In order to investigate this behavior, three different prefabricated vertical drains have been simulated under an embankment. The finite element software PLAXIS has been carried out for analyzing the displacements and excess pore pressures. The results showed that the consolidation time and induced excess pore pressure are highly depended to the discharge capacity of the prefabricated vertical drain. The increase in the discharge capacity leads to decrease the consolidation process and the induced excess pore pressure. Moreover, it was seen that the vertical drains spacing does not have any significant effect on the consolidation time. However, the increase in the drains spacing would decrease the system stiffness.
Abstract: The paper presents design and production of thin-walled U-profile footbridge made of UHPFRC. The main structure of the bridge is one prefabricated shell structure made of UHPFRC with dispersed steel fibers without any conventional reinforcement. The span of the bridge structure is 10 m and the clear width of 1.5 m. The thickness of the UHPFRC shell structure oscillated in an interval of 30-45 mm. Several calculations were made during the bridge design and compared with the experiments. For the purpose of verifying the calculations, a segment of 1.5 m was first produced, followed by the whole footbridge for testing. After the load tests were done, the design was optimized to cast the final footbridge.
Abstract: Internal insulation of external walls is often problematic due to increased moisture content in the wall and interstitial or surface condensation risk. In this paper, the hygrothermal performance of prefabricated, concrete, large panel, external wall typical for WK70 system, commonly used in Poland in the 70’s, with inside, additional insulation was investigated. Thermal insulation board made out of hygroscopic, natural materials with moisture buffer capacity and extruded polystyrene (EPS) board was used as interior insulation. Experience with this natural insulation is rare in Poland. The analysis was performed using WUFI software. First of all, the impact of various standard boundary conditions on the behavior of the different wall assemblies was tested. The comparison of results showed that the moisture class according to the EN ISO 13788 leads to too high values of total moisture content in the wall since the boundary condition according to the EN 15026 should be usually applied. Then, hygrothermal 1D-simulations were conducted by WUFI Pro for analysis of internally added insulation, and the weak point like the joint of the wall with the concrete ceiling was verified using 2D simulations. Results showed that, in the Warsaw climate and the indoor conditions adopted in accordance with EN 15026, in the tested wall assemblies, regardless of the type of interior insulation, there would not be any problems with moisture - inside the structure and on the interior surface.
Abstract: There is an urgent need nowadays to reduce energy demand and the current level of greenhouse gas emission and use renewable energy sources increase in energy efficiency. On the other hand, the European Union (EU) countries are largely dependent on energy imports and are vulnerable to disruption in energy supply, which may, in turn, threaten the functioning of their current economic structure. Residential buildings represent a significant part of the energy consumption of the building stock. Only a small part of the building stock is exchanged every year, thus it is essential to increase the energy efficiency of the existing buildings. Present paper focuses on the buildings built with industrialized technology only, and their opportunities in the boundaries of nearly zero-energy regulation. Current paper shows the emergence of panel construction method, and past and present of the ‘panel’ problem in Hungary with a short outlook to Europe. The study shows as well as the possibilities for meeting the nearly zero and cost optimized requirements for residential buildings by analyzing the renovation scenarios of an existing residential typology.
Abstract: More than half of the urban population in Romania lives today in residential buildings made out of large prefabricated reinforced concrete panels. Since their initial design was made in the 1960’s, these housing units are now being technically and morally outdated, consuming large amounts of energy for heating, cooling, ventilation and lighting, while failing to meet the needs of the contemporary life-style. Due to their widespread use, the design of a system that improves their energy efficiency would have a real impact, not only on the energy consumption of the residential sector, but also on the quality of life that it offers. Furthermore, with the transition of today’s existing power grid to a “smart grid”, buildings could become an active element for future electricity networks by contributing in micro-generation and energy storage. One of the most addressed issues today is to find locally adapted strategies that can be applied considering the 20-20-20 EU policy criteria and to offer sustainable and innovative solutions for the cost-optimal energy performance of buildings adapted on the existing local market. This paper presents a possible adaptive design scenario towards sustainable retrofitting of these housing units. The apartments are transformed in order to meet the current living requirements and additional extensions are placed on top of the building, replacing the unused roof space, acting not only as housing units, but as active solar energy collection systems. An adaptive building envelope is ensured in order to achieve overall air-tightness and an elevator system is introduced to facilitate access to the upper levels.
Abstract: In this study, the feasibility of incorporating ceramic
waste from bricks (perforated brick and double hollow brick) and
extruded polystyrene (XPS) waste, is analysed.
Results show that it is possible to incorporate up to 25% of
ceramic waste and 4% of XPS waste over the weight of gypsum in a
gypsum matrix. Furthermore, with the addition of ceramic waste an
8% of surface hardness increase and a 25% of capillary water
absorption reduction can be obtained. On the other hand, with the
addition of XPS, a 26% reduction of density and a 37% improvement
of thermal conductivity can be obtained.
The obtained results are favorable to use these materials in order to
produce prefabricated gypsum and also as material for interior
cladding walls.
Abstract: The design philosophy of building structure has been
changing time to time. The reason for this is because of an increase of
human inertest, an improved building materials and technology that
will impact how we live, to speed up construction period and natural
effect which includes earthquake disasters and environmental effect.
One technique which takes in to account the above case is using a
prefabricable structural system. In which each and every structural
element is designed and prefabricated and assembled on a site so that
the construction speed is increased and the environmental impact is
also enhanced. This system has an immense advantage such as: reduce
construction cost, reusable, recyclable, speed up construction period
and less environmental effect. In this study, it is tried to present some
of the developed and evaluated structural elements of building
structures.
Abstract: Modular structural systems are constructed using a
method that they are assembled with prefabricated unit modular
frames on-site. This provides a benefit that can significantly reduce
building construction time. The structural design is usually carried out
under the assumption that their load-carrying mechanism is similar to
that of traditional steel moment-resisting systems. However, both
systems are different in terms of beam-column connection details
which may strongly influence the lateral structural behavior. Specially,
the presence of access holes in a beam-column joint of a unit modular
frame could cause undesirable failure during strong earthquakes.
Therefore, this study carried out finite element analyses (FEMs) of
unit modular frames to investigate the cyclic behavior of beam-column
joints with the access holes. Analysis results show that the unit
modular frames present stable cyclic response with large deformation
capacities and their joints are classified into semi-rigid connections
even if there are access holes.
Abstract: When dealing with safety in structures, the connections between structural components play an important role. Robustness of a structure as a whole depends both on the load- bearing capacity of the structural component and on the structures capacity to resist total failure, even though a local failure occurs in a component or a connection between components. To avoid progressive collapse it is necessary to be able to carry out a design for connections. A connection may be executed with anchors to withstand local failure of the connection in structures built with prefabricated components. For the design of these anchors, a model is developed for connections in structures performed in prefabricated autoclaved aerated concrete components. The design model takes into account the effect of anchors placed close to the edge, which may result in splitting failure. Further the model is developed to consider the effect of reinforcement diameter and anchor depth. The model is analytical and theoretically derived assuming a static equilibrium stress distribution along the anchor. The theory is compared to laboratory test, including the relevant parameters and the model is refined and theoretically argued analyzing the observed test results. The method presented can be used to improve safety in structures or even optimize the design of the connections
Abstract: Recently in the field of bridges that are newly built or
repaired, fast construction is required more than ever. For these
reasons, precast prefabricated bridge that enables rapid construction is
actively discussed and studied today. In South Korea, it is called
modular bridge. Cross beam is an integral component of modular
bridge. It functions for load distribution, reduction of bending
moment, resistance of horizontal strength on lateral upper structure. In
this study, the structural characteristics of domestic and foreign cross
beam types were compared. Based on this, alternative cross beam
connection types suitable for modular bridge were selected. And
bulb-T girder specimens were fabricated with each type of connection.
The behavior of each specimen was analyzed under static loading, and
cross beam connection type which is expected to be best suited to
modular bridge proposed.
Abstract: GFRG(Glass Fiber Reinforced Gypsum) wall is a green product which can erect a building fast in prefabricated method, but its application to high-rise residential buildings is limited for its poor lateral stiffness. This paper has proposed a modification to GFRG walls structure to increase its lateral stiffness, which aiming to erect small high-rise residential buildings as load-bearing walls. The elastic finite element analysis to it has shown the lateral deformation feature and the distributions of the axial force and the shear force. The analysis results show that the new GFRG reinforced concrete wall can be used for small high-rise residential buildings.
Abstract: In construction of any structure, the aesthetic and utility values should be considered in such a way as to make the structure cost-effective. Most structures are composed of elements and joints which are very critical in any skeletal space structure because they majorly determine the performance of the structure. In early times, most space structures were constructed using rigid joints which had the advantage of better performing structures as compared to pin-jointed structures but with the disadvantage of requiring all the construction work to be done on site. The discovery of semi-rigid joints now enables connections to be prefabricated and quickly assembled on site while maintaining good performance. In this paper, cost-effective is discussed basing on strength of connectors at the joints, buckling of joints and overall structure, and the effect of initial geometrical imperfections. Several existing joints are reviewed by classifying them into categories and discussing where they are most suited and how they perform structurally. Also, finite element modeling using ABAQUS is done to determine the buckling behavior. It is observed that some joints are more economical than others. The rise to span ratio and imperfections are also found to affect the buckling of the structures. Based on these, general principles that guide the design of cost-effective joints and structures are discussed.
Abstract: With respect to the dissipation of energy through
plastic deformation of joints of prefabricated wall units, the paper
points out the principal importance of efficient reinforcement of the
prefabricated system at its joints. The method, quality and amount of
reinforcement are essential for reaching the necessary degree of joint
ductility. The paper presents partial results of experimental research
of vertical joints of prefabricated units exposed to monotonously
rising loading and repetitive shear force and formulates a conclusion
that the limit state of the structure as a whole is preceded by the
disintegration of joints, or that the structure tends to pass from
linearly elastic behaviour to non-linearly elastic to plastic behaviour
by exceeding the proportional elastic limit in joints.Experimental
verification on a model of a 7-storey prefabricated structure revealed
weak points in its load-bearing systems, mainly at places of critical
points around openings situated in close proximity to vertical joints
of mutually perpendicularly oriented walls.
Abstract: This paper presents a experiment to estimate the
influences of cutting conditions in microstructure changes of
machining austenitic 304 stainless steel, especially for wear insert. The
wear insert were prefabricated with a width of 0.5 mm. And the forces,
temperature distribution, RS, and microstructure changes were
measured by force dynamometer, infrared thermal camera, X-ray
diffraction, XRD, SEM, respectively. The results told that the different
combinations of machining condition have a significant influence on
machined surface microstructure changes. In addition to that, the
ANOVA and AOMwere used to tell the different influences of cutting
speed, feed rate, and wear insert.
Abstract: Although many studies on the assembly technology of
the bridge construction have dealt mostly with on the pier, girder or the
deck of the bridge, studies on the prefabricated barrier have rarely been
performed. For understanding structural characteristics and
application of the concrete barrier in the modular bridge, which is an
assembly of structure members, static loading test was performed.
Structural performances as a road barrier of the three methods,
conventional cast-in-place(ST), vertical bolt connection(BVC) and
horizontal bolt connection(BHC) were evaluated and compared
through the analyses of load-displacement curves, strain curves of the
steel, concrete strain curves and the visual appearances of crack
patterns. The vertical bolt connection(BVC) method demonstrated
comparable performance as an alternative to conventional
cast-in-place(ST) while providing all the advantages of prefabricated
technology. Necessities for the future improvement in nuts
enforcement as well as legal standard and regulation are also
addressed.
Abstract: The most important parameter in transformers life
expectancy is the hot-spot temperature level which accelerates the
rate of aging of the insulation. The aim of this paper is to present
thermal models for transformers loaded at prefabricated MV/LV
transformer substations and outdoor situations. The hot-spot
temperature of transformers is studied using their top-oil temperature
rise models. The thermal models proposed for hot-spot and top-oil
temperatures of different operating situations are compared. Since the
thermal transfer is different for indoor and outdoor transformers
considering their operating conditions, their hot-spot thermal models
differ from each other. The proposed thermal models are verified by
the results obtained from the experiments carried out on a typical
1600 kVA, 30 /0.4 kV, ONAN transformer for both indoor and
outdoor situations.