An Analytical Study on Rotational Capacity of Beam-Column Joints in Unit Modular Frames

Modular structural systems are constructed using a
method that they are assembled with prefabricated unit modular
frames on-site. This provides a benefit that can significantly reduce
building construction time. The structural design is usually carried out
under the assumption that their load-carrying mechanism is similar to
that of traditional steel moment-resisting systems. However, both
systems are different in terms of beam-column connection details
which may strongly influence the lateral structural behavior. Specially,
the presence of access holes in a beam-column joint of a unit modular
frame could cause undesirable failure during strong earthquakes.
Therefore, this study carried out finite element analyses (FEMs) of
unit modular frames to investigate the cyclic behavior of beam-column
joints with the access holes. Analysis results show that the unit
modular frames present stable cyclic response with large deformation
capacities and their joints are classified into semi-rigid connections
even if there are access holes.





References:
[1] M. T. Gorgolewski, P. J. Grubb, and R. M. Lawson, Modular
Construction Using Light Steel Framing: Design of Residential Buildings.
Berkshire: Steel Construction Institute, 2001.
[2] C. D. Annan, M. A. Youssef, and M. H. El Naggar, “Experimental
evaluation of the seismic performance of modular steel-braced frames”,
Engineering Structures, 31.7, pp.1435~1446, Mar. 2009.
[3] R. M. Lawson, R. G. Ogden, and R. Bergin, “Application for Modular
Construction in High-Rise Buildings”, J. Archi. Eng., 18, pp.148~156,
2012
[4] S. G. Hong, B. H. Cho, K. S. Chung and J. H. Moon, “Behavior of Framed
Modular Building System with Double Skin Steel Panels”, J. Constr.
Steel Res., 67, pp.936~946, 2011.
[5] D. J. Fielding, and J. S. Huang, “Shear in steel beam-to-column
connections”, Welding Journal, 50.7,pp.313~326, Jul. 1971.
[6] H. Krawinkler, “Shear in beam-column joints in seismic design of steel
frames”, Engineering Journal, 15.3, pp.82~91, 1978.
[7] ABAQUS 6.10, Analysis User’s Manual, Providence, RI: Dassault
Systemes Simulia Corp., 2010.
[8] AISC, Seismic Provisions for Structural Steel Buildings, Chicago, IL:
Americal Institute of Steel Construction, 2005.
[9] AIK, Korean Building Code 2009 (KBC 2009), Seoul: Architectural
Institute of Korea, 2010.
[10] CEN, EN 1993-1-8:2005, Eurocode 3: design of steel structures, part 1.8:
design of joints, London: British Standards Institution, 2005.