Capacity of Anchors in Structural Connections

When dealing with safety in structures, the connections between structural components play an important role. Robustness of a structure as a whole depends both on the load- bearing capacity of the structural component and on the structures capacity to resist total failure, even though a local failure occurs in a component or a connection between components. To avoid progressive collapse it is necessary to be able to carry out a design for connections. A connection may be executed with anchors to withstand local failure of the connection in structures built with prefabricated components. For the design of these anchors, a model is developed for connections in structures performed in prefabricated autoclaved aerated concrete components. The design model takes into account the effect of anchors placed close to the edge, which may result in splitting failure. Further the model is developed to consider the effect of reinforcement diameter and anchor depth. The model is analytical and theoretically derived assuming a static equilibrium stress distribution along the anchor. The theory is compared to laboratory test, including the relevant parameters and the model is refined and theoretically argued analyzing the observed test results. The method presented can be used to improve safety in structures or even optimize the design of the connections




References:
[1] S. Kokot, "Progressive collaps - structure of industrial plastics".
Ispra,Italy Elsevier 2012.
[2] B.A. Izzudin, "Progressive collapse of mulit-storey buildings due to
sudden column loss". London, United Kingdom Elsevier 2007.
[3] A.G. Vlassis, "Progressive collapse of multistory building due to failed
floor impact". London, United Kingdom Elsevier 2009.
[4] Ivan Gomez, Amit Kanvinde, Chris Smith and Gregory Deierlein,
"Shear transfer in exposed base plates," American Institute of Steel
Construction, 2009
[5] Ö. Çalışkan, S. Yılmaz, H. Kaplan and N. Kıraç, "Shear strength of
epoxy anchors embedded into low strength," Construction and Building
Materials 38, Elsevier, Sep. 2012 concrete
[6] Y. Zhang, "Dynamic behavior of multiple-anchor connections in cracked
concrete," Ph.D Dissertation, University of Texas at Austin, Apr. 1997
[7] R. Eligehausen, Rainer Mallée and John F. Silva, "Anchorage In
Concrete Construction", Ernst & Sohn, 2006
[8] TC250, "EN1992-1-1, Eurcode 2 - Design of concrete structures - part
1-1, general rules and rules for building", CEN, Brussels, Belgium 2004.
[9] TC177,"EN12602 - Prefabricated reinforced components of autoclaved
aerated concrete", CEN, Brussels, Belgium 2008.
[10] F. L. L. B. Carneiro, and A.BAHCELLOS, "Tensile Strength of
Concretes." R.I.L.E.M. Bulletin No. 13, Mar. 1953, pp. 9%125.