Abstract: The induction hardening machines are utilized in
the industries which modify machine parts and tools needed to
achieve high ware resistance. This paper describes the model of
induction heating process design of inverter circuit and the results
of induction surface hardening of heating coil. In the design of
heating coil, the shape and the turn numbers of the coil are very
important design factors because they decide the overall operating
performance of induction heater including resonant frequency, Q
factor, efficiency and power factor. The performance will be tested
by experiments in some cases high frequency induction hardening
machine.
Abstract: Optimization and control of reactive power
distribution in the power systems leads to the better operation of the
reactive power resources. Reactive power control reduces
considerably the power losses and effective loads and improves the
power factor of the power systems. Another important reason of the
reactive power control is improving the voltage profile of the power
system. In this paper, voltage and reactive power control using
Neural Network techniques have been applied to the 33 shines-
Tehran Electric Company. In this suggested ANN, the voltages of PQ
shines have been considered as the input of the ANN. Also, the
generators voltages, tap transformers and shunt compensators have
been considered as the output of ANN. Results of this techniques
have been compared with the Linear Programming. Minimization of
the transmission line power losses has been considered as the
objective function of the linear programming technique. The
comparison of the results of the ANN technique with the LP shows
that the ANN technique improves the precision and reduces the
computation time. ANN technique also has a simple structure and
this causes to use the operator experience.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: Linear induction motors are used in various industries
but they have some specific phenomena which are the causes for
some problems. The most important phenomenon is called end effect.
End effect decreases efficiency, power factor and output force and
unbalances the phase currents. This phenomenon is more important
in medium and high speeds machines. In this paper a factor, EEF , is
obtained by an accurate equivalent circuit model, to determine the
end effect intensity. In this way, all of effective design parameters on
end effect is described. Accuracy of this equivalent circuit model is
evaluated by two dimensional finite-element analysis using ANSYS.
The results show the accuracy of the equivalent circuit model.
Abstract: This paper presents a pulse doubling technique in a 12-pulse ac-dc converter which supplies direct torque controlled motor drives (DTCIMD-s) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant changes in the installations and yields in harmonic reduction in both ac and dc sides. The 12-pulse rectified output voltage is accomplished via two paralleled six-pulse ac-dc converters each of them consisting of three-phase diode bridge rectifier. An autotransformer is designed to supply the rectifiers. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. Independent operation of paralleled diode-bridge rectifiers, i.e. dc-ripple re-injection methodology, requires a Zero Sequence Blocking Transformer (ZSBT). Finally, a tapped interphase reactor is connected at the output of ZSBT to double the pulse numbers of output voltage up to 24 pulses. The aforementioned structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6- pulse, 12-pulse, and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 5% for the proposed topology at various loads.
Abstract: A novel three-phase active power filter (APF) circuit with photovoltaic (PV) system to improve the quality of service and to reduce the capacity of energy storage capacitor is presented. The energy balance concept and sampling technique were used to simplify the calculation algorithm for the required utility source current and to control the voltage of the energy storage capacitor. The feasibility was verified by using the Pspice simulations and experiments. When the APF mode was used during non-operational period, not only the utilization rate, power factor and power quality could be improved, but also the capacity of energy storage capacitor could sparing. As the results, the advantages of the APF circuit are simplicity of control circuits, low cost, and good transient response.
Abstract: WOLED is widely used as lighting for high efficacy and little power consumption. In this research, power factor testing between WOLED and fluorescent lamp to see which one is more efficient in consuming energy. Since both lamps use semiconductor components, so calculation of the power factor need to consider the effects of harmonics. Harmonic make bigger losses. The study is conducted by comparing the value of the power factor regardless of harmonics (DPF) and also by included the harmonics (TPF). The average value of DPF of fluorescent is 0.953 while WOLED is 0.972. The average value of TPF of fluorescent is 0.717 whereas WOLED is 0.933. So from the review of power factor WOLED is more energy efficient than fluorescent lamp.
Abstract: This paper presents modeling and analysis of 12-phase distribution static compensator (DSTATCOM), which is capable of balancing the source currents in spite of unbalanced loading and phase outages. In addition to balance the supply current, the power factor can be set to a desired value. The theory of instantaneous symmetrical components is used to generate the twelve-phase reference currents. These reference currents are then tracked using current controlled voltage source inverter, operated in a hysteresis band control scheme. An ideal compensator in place of physical realization of the compensator is used. The performance of the proposed DTATCOM is validated through MATLAB simulation and detailed simulation results are given.
Abstract: In this paper, we apply the PQ theory with shunt active power filter in an unbalanced and distorted power system voltage to compensate the perturbations generated by non linear load. The power factor is also improved in the current source. The PLL system is used to extract the fundamental component of the even sequence under conditions mentioned of the power system voltage.
Abstract: Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals with the performance evaluation through analytical studies and practical implementation on an existing system. A fast acting error adaptive controller is developed suitable both for contactor and thyristor switched capacitors. The switching operations achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing small percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement so as maintain power factor near unity always. It is elegant, closed loop microcontroller system having the features of self regulation in adaptive mode for automatic adjustment. It is successfully tested on a distribution transformer of three phase 50 Hz, Dy11, 11KV/440V, 125 KVA capacity and the functional feasibility and technical soundness are established. The controller developed is new, adaptable to both LT & HT systems and practically established to be giving reliable performance.
Abstract: Properly sized capacitor banks are connected across induction motors for several reasons including power factor correction, reducing distortions, increasing capacity, etc. Total harmonic distortion (THD) and power factor (PF) are used in such cases to quantify the improvements obtained through connection of the external capacitor banks. On the other hand, one of the methods for assessing the motor internal condition is by the use of Park-s pattern analysis. In spite of taking adequate precautionary measures, the capacitor banks may sometimes malfunction. Such a minor fault in the capacitor bank is often not apparently discernible. This may however, give rise to substantial degradation of power factor correction performance and may also damage the supply profile. The case is more severe with the fact that the Park-s pattern gets distorted due to such external capacitor faults, and can give anomalous results about motor internal fault analyses. The aim of this paper is to present simulation and hardware laboratory test results to have an understanding of the anomalies in harmonic distortion and Park-s pattern analyses in induction motors due to capacitor bank defects.
Abstract: This paper explores steady-state characteristics of
grid-connected doubly fed induction motor (DFIM) in case of unity
power factor operation. Based on the synchronized mathematical
model, analytic determination of the control laws is presented and
illustrated by various figures to understand the effect of the applied
rotor voltage on the speed and the active power. On other hand,
unlike previous works where the stator resistance was neglected, in
this work, stator resistance is included such that the equations can be
applied to small wind turbine generators which are becoming more
popular. Finally the work is crowned by integration of the studied
induction generator in a wind system where an open loop control is
proposed confers a remarkable simplicity of implementation
compared to the known methods.
Abstract: This paper presents the experimental results of
leakage current waveforms which appears on porcelain insulator
surface due to existence of artificial pollutants. The tests have been
done using the chemical compounds of NaCl, Na2SiO3, H2SO4, CaO,
Na2SO4, KCl, Al2SO4, MgSO4, FeCl3, and TiO2. The insulator
surface was coated with those compounds and dried. Then, it was
tested in the chamber where the high voltage was applied. Using
correspondence analysis, the result indicated that the fundamental
harmonic of leakage current was very close to the applied voltage
and third harmonic leakage current was close to the yielded leakage
current amplitude. The first harmonic power was correlated to first
harmonic amplitude of leakage current, and third harmonic power
was close to third harmonic one. The chemical compounds of H2SO4
and Na2SiO3 affected to the power factor of around 70%. Both are the
most conductive, due to the power factor drastically increase among
the chemical compounds.
Abstract: Analytical expression for maximum power transfer
through a transmission line limited by voltage stability has been
formulated using exact representation of transmission line with
ABCD parameters. The expression has been used for plotting PV
curve at different power factors of a radial transmission line.
Limiting values of reactive power have been obtained.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: This paper deals with the simulation of a Boost Power Factor Correction (PFC) Converter with Electro Magnetic Interference (EMI) Filter. The diode rectifier with output capacitor gives poor power factor. The Boost Converter of PFC Circuit is analyzed and then simulated with diode rectifier. The Boost PFC Converter with EMI Filter is simulated for resistive load. The power factor is improved using the proposed converter.
Abstract: Fluorescent and WOLED are widely used because it consumes less energy. However, both lamps cause a harmonics because it has semiconductors components. Harmonic is a distorted sinusoidal electric wave and cause excess heat. This study compares the amount of harmonics generated by both lamps. The test shows that both lamps have THDv(Total Harmonics Distortion of Voltage) almost the same with average 2.5% while the average of WOLED's THDi(Total Harmonics Distortion of Current) is lower than fluorescent has. The average WOLED's THDi is 29.10 % and fluorescent's 'THDi is 87. 23 %.
Abstract: This paper presents the study of a variable speed wind
energy conversion system based on a Doubly Fed Induction Generator
(DFIG) based on a sliding mode control applied to achieve control of
active and reactive powers exchanged between the stator of the DFIG
and the grid to ensure a Maximum Power Point Tracking (MPPT) of
a wind energy conversion system. The proposed control algorithm is
applied to a DFIG whose stator is directly connected to the grid and
the rotor is connected to the PWM converter. To extract a maximum
of power, the rotor side converter is controlled by using a stator
flux-oriented strategy. The created decoupling control between active
and reactive stator power allows keeping the power factor close to
unity. Simulation results show that the wind turbine can operate at
its optimum energy for a wide range of wind speed.
Abstract: Most high-performance ac drives utilize a current
controller. The controller switches a voltage source inverter (VSI)
such that the motor current follows a set of reference current
waveforms. Fixed-band hysteresis (FBH) current control has been
widely used for the PWM inverter. We want to apply the same
controller for the PWM AC chopper. The aims of the controller is to
optimize the harmonic content at both input and output sides, while
maintaining acceptable losses in the ac chopper and to control in
wide range the fundamental output voltage. Fixed band controller has
been simulated and analyzed for a single-phase AC chopper and are
easily extended to three-phase systems. Simulation confirmed the
advantages and the excellent performance of the modulation method
applied for the AC chopper.
Abstract: The controllable electrical loss which consists of the
copper loss and iron loss can be minimized by the optimal control of
the armature current vector. The control algorithm of current vector
minimizing the electrical loss is proposed and the optimal current
vector can be decided according to the operating speed and the load
conditions. The proposed control algorithm is applied to the
experimental PM motor drive system and this paper presents a
modern approach of speed control for permanent magnet
synchronous motor (PMSM) applied for Electric Vehicle using a
nonlinear control. The regulation algorithms are based on the
feedback linearization technique. The direct component of the current
is controlled to be zero which insures the maximum torque operation.
The near unity power factor operation is also achieved. More over,
among EV-s motor electric propulsion features, the energy efficiency
is a basic characteristic that is influenced by vehicle dynamics and
system architecture. For this reason, the EV dynamics are taken into
account.