Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: At present, it is very common to find renewable
energy resources, especially wind power, connected to distribution
systems. The impact of this wind power on voltage distribution levels
has been addressed in the literature. The majority of this works deals
with the determination of the maximum active and reactive power
that is possible to be connected on a system load bus, until the
voltage at that bus reaches the voltage collapse point. It is done by the
traditional methods of PV curves reported in many references.
Theoretical expression of maximum power limited by voltage
stability transfer through a grid is formulated using an exact
representation of distribution line with ABCD parameters. The
expression is used to plot PV curves at various power factors of a
radial system. Limited values of reactive power can be obtained. This
paper presents a method to study the relationship between the active
power and voltage (PV) at the load bus to identify the voltage
stability limit. It is a foundation to build a permitted working
operation region in complying with the voltage stability limit at the
point of common coupling (PCC) connected wind farm.
Abstract: In this paper, we propose an easily computable proximity index for predicting voltage collapse of a load bus using only measured values of the bus voltage and power; Using these measurements a polynomial of fourth order is obtained by using LES estimation algorithms. The sum of the absolute values of the polynomial coefficient gives an idea of the critical bus. We demonstrate the applicability of our proposed method on 6 bus test system. The results obtained verify its applicability, as well as its accuracy and the simplicity. From this indicator, it is allowed to predict the voltage instability or the proximity of a collapse. Results obtained by the PV curve are compared with corresponding values by QV curves and are observed to be in close agreement.
Abstract: Analytical expression for maximum power transfer
through a transmission line limited by voltage stability has been
formulated using exact representation of transmission line with
ABCD parameters. The expression has been used for plotting PV
curve at different power factors of a radial transmission line.
Limiting values of reactive power have been obtained.
Abstract: Estimation of voltage stability based on optimal
filtering method is presented. PV curve is used as a tool for voltage stability analysis. Dynamic voltage stability estimation is done by
using particle filter method. Optimum value (nose point) of PV curve can be estimated by estimating parameter of PV curve equation
optimal value represents critical voltage and
condition at specified point of measurement. Voltage stability is then estimated by analyzing loading margin condition c stimating equation. This
maximum loading
ecified dynamically.