Abstract: Doubly Fed Induction Generator (DFIG) is one of the most reliable wind generator. Major problem in wind power generation is to generate Sinusoidal signal with very low THD on variable speed caused by inverter two levels used. This paper presents a multi-level inverter whose objective is to reduce the THD and the dimensions of the output filter. This work proposes a three-level NPC-type inverter, the results simulation are presented demonstrating the efficiency of the proposed inverter.
Abstract: The technology of superconductivity has developed in many power system devices such as transmission cable, transformer, current limiter, motor and generator. Superconducting wires can carry high density current without loss, which is the capability that is used to design the compact, lightweight and more efficient electrical machines. Superconducting motors have found applications in marine and air propulsion systems as well as superconducting generators are considered in low power hydraulic and wind generators. This paper presents a rim-driven superconducting synchronous generator for hydraulic power plant. The rim-driven concept improves the performance of hydro turbine. Furthermore, high magnetic field that is produced by superconducting windings allows replacing the rotor core. As a consequent, the volume and weight of the machine is decreased significantly. In this paper, a 1 MW coreless rim-driven superconducting synchronous generator is designed. Main performance characteristics of the proposed machine are then evaluated using finite elements method and compared to an ordinary similar size synchronous generator.
Abstract: In this article, the mathematical model is presented, and simulations were carried out using specialized software such as MATLAB before the construction of a 900-W wind turbine. The present study was conducted with the intention of taking advantage of the rotation of the blades of the wind generator after going through a process of amplification of speed by means of a system of gears to finally mechanically couple two electric generators of similar characteristics. This coupling allows generating a maximum voltage of 6 V in DC for each generator and putting in series the 12 V DC is achieved, which is later stored in batteries and used when the user requires it. Laboratory tests were made to verify the level of power generation produced based on the wind speed at the entrance of the blades.
Abstract: Due to the increased penetration of renewable energy resources in the distribution system, the system is no longer passive in nature. In this paper, a steady state analysis of the distribution system has been done with the inclusion of wind generation. The modeling of wind turbine generator system and wind generator has been made to obtain the average active and the reactive power injection into the system. The study has been conducted on a IEEE-33 bus system with two wind generators. The present research work is useful not only to utilities but also to customers.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: One of the most important power quality issues is voltage flicker. Nowadays this issue also impacts the power system all over the world. The fact of the matter is that the more and the larger capacity of wind generator has been installed. Under unstable wind power situation, the variation of output current and voltage have caused trouble to voltage flicker. Hence, the major purpose of this study is to analyze the impact of wind generator on voltage flicker of power system. First of all, digital simulation and analysis are carried out based on wind generator operating under various system short circuit capacity, impedance angle, loading, and power factor of load. The simulation results have been confirmed by field measurements.
Abstract: At present, it is very common to find renewable
energy resources, especially wind power, connected to distribution
systems. The impact of this wind power on voltage distribution levels
has been addressed in the literature. The majority of this works deals
with the determination of the maximum active and reactive power
that is possible to be connected on a system load bus, until the
voltage at that bus reaches the voltage collapse point. It is done by the
traditional methods of PV curves reported in many references.
Theoretical expression of maximum power limited by voltage
stability transfer through a grid is formulated using an exact
representation of distribution line with ABCD parameters. The
expression is used to plot PV curves at various power factors of a
radial system. Limited values of reactive power can be obtained. This
paper presents a method to study the relationship between the active
power and voltage (PV) at the load bus to identify the voltage
stability limit. It is a foundation to build a permitted working
operation region in complying with the voltage stability limit at the
point of common coupling (PCC) connected wind farm.
Abstract: This article simulates the wind generator set which has
two fault bearing collar rail destruction and the gear box oil leak fault.
The electric current signal which produced by the generator, We use
Empirical Mode Decomposition (EMD) as well as Fast Fourier
Transform (FFT) obtains the frequency range-s signal figure and
characteristic value. The last step is use a kind of Artificial Neural
Network (ANN) classifies which determination fault signal's type and
reason. The ANN purpose of the automatic identification wind
generator set fault..
Abstract: This paper proposes the method combining artificial neural network with particle swarm optimization (PSO) to implement the maximum power point tracking (MPPT) by controlling the rotor speed of the wind generator. With the measurements of wind speed, rotor speed of wind generator and output power, the artificial neural network can be trained and the wind speed can be estimated. The proposed control system in this paper provides a manner for searching the maximum output power of wind generator even under the conditions of varying wind speed and load impedance.
Abstract: In this paper present a sensorless maximum wind power extraction for variable speed constant frequency (VSCF) wind power generation systems with a doubly-fed induction generators (DFIG), to ensure stability and to impose the ideal feedback control solution despite of model uncertainties , using the principles of an active and reactive power controller (DPC) a robust sliding mode power control has been proposed to guarantees fast response times and precise control actions for control the active and reactive power independently. The simulation results in MATLAB/Simulink platform confirmed the good dynamic performance of power control approach for DFIGbased variable speed wind turbines.
Abstract: This paper proposes the method combining artificial
neural network (ANN) with particle swarm optimization (PSO) to
implement the maximum power point tracking (MPPT) by controlling
the rotor speed of the wind generator. First, the measurements of wind
speed, rotor speed of wind power generator and output power of wind
power generator are applied to train artificial neural network and to
estimate the wind speed. Second, the method mentioned above is
applied to estimate and control the optimal rotor speed of the wind
turbine so as to output the maximum power. Finally, the result reveals
that the control system discussed in this paper extracts the maximum
output power of wind generator within the short duration even in the
conditions of wind speed and load impedance variation.
Abstract: The impact of fixed speed squirrel cage type as well as
variable speed doubly fed induction generators (DFIG) on dynamic
performance of a multimachine power system has been investigated.
Detailed models of the various components have been presented and
the integration of asynchronous and synchronous generators has been
carried out through a rotor angle based transform. Simulation studies
carried out considering the conventional dynamic model of squirrel
cage asynchronous generators show that integration, as such, could
degrade to the AC system performance transiently. This article
proposes a frequency or power controller which can effectively
control the transients and restore normal operation of fixed speed
induction generator quickly. Comparison of simulation results
between classical cage and doubly-fed induction generators indicate
that the doubly fed induction machine is more adaptable to
multimachine AC system. Frequency controller installed in the DFIG