Abstract: The paper introduces a method to efficiently simulate nonlinear changing electrostatic fields occurring in micro-electromechanical systems (MEMS). Large deflections of the capacitor electrodes usually introduce nonlinear electromechanical forces on the mechanical system. Traditional finite element methods require a time-consuming remeshing process to capture exact results for this physical domain interaction. In order to accelerate the simulation process and eliminate the remeshing process, a formulation of a strongly coupled electromechanical transducer element will be introduced which uses a combination of finite-element with an advanced mesh morphing technique using radial basis functions (RBF). The RBF allows large geometrical changes of the electric field domain while retain high element quality of the deformed mesh. Coupling effects between mechanical and electrical domains are directly included within the element formulation. Fringing field effects are described accurate by using traditional arbitrary shape functions.
Abstract: Additive Manufacturing is utilized in medical automation to optimize and integrate materials in accordance to energy source type leading to treatment gaps in industrial designs for extreme biomechanical forces in relation with vibration, fluid transfer, and multi-physics performance. Elastic/piezoelectric materials are strongly ordered inter-metallics for characterization of distinct features that can provide excellent compositional strength, ductility, and uniformity for superelastic shape memory alloy on medical devices. Several theories can be derived to analyze and interpret complex problems on the application of functionally graded materials used in medical machinery for genome architecture. Numerical principles on fluid and thermodynamics such as Reynolds number, Darcy rule, Friction Factor and Heat Rate are integrated with fundamental equation of numerical vibrations using Helmholtz equation. Simulation by Large Eddy approach and genetic modeling can be done using Physical and Chemical Vapor Deposition following various theories on Carrera’s Unified Formulations by comparing with various Classical Plate Theories, Equivalent Single Layer Theories, Layer-Wise Theories, Zig-Zag Theories, and Mixed Refined Variational Theories. The subject is approached towards the application of ethical and legal problems in order to resolve issues on consent and return of results.
Abstract: The object of this study is to investigate the effect of pulsator on washing performance quantitatively for front-loading washer. The front-loading washer with pulsator shows washing performance improvement of 18% and the particle-based body simulation technique has been applied to figure out the relation between washing performance and mechanical forces exerted on textile during washing process. As a result, the mechanical forces, such as collision force and strain force, acting on the textile have turned out to be about twice numerically. The washing performance improvement due to additional pulsate system has been utilized for customers to save 50% of washing time.
Abstract: The gait pattern in people that present motor limitations foment the demand for auxiliary locomotion devices. These artifacts for movement assistance vary according to its shape, size and functional features, following the clinical applications desired. Among the ortheses of lower limbs, the ankle-foot orthesis aims to improve the ability to walk in people with different neuromuscular limitations, although they do not always answer patients' expectations for their aesthetic and functional characteristics. The purpose of this study is to explore the possibility of using new design in additive manufacturer to reproduce the shape and functional features of a ankle-foot orthesis in an efficient and modern way. Therefore, this work presents a study about the performance of the mechanical forces through the analysis of finite elements in an ankle-foot orthesis. It will be demonstrated a study of distribution of the stress on the orthopedic device in orthostatism and during the movement in the course of patient's walk.
Abstract: Structure-borne noise is an important aspect of
offshore platform sound field. It can be generated either directly by
vibrating machineries induced mechanical force, indirectly by the
excitation of structure or excitation by incident airborne noise.
Therefore, limiting of the transmission of vibration energy
throughout the offshore platform is the key to control the structureborne
noise. This is usually done by introducing damping treatment
to the steel structures. Two types of damping treatment using onboard
are presented. By conducting a Statistical Energy Analysis
(SEA) simulation on a jack-up rig, the noise level in the source room,
the neighboring rooms, and remote living quarter cabins are
compared before and after the damping treatments been applied. The
results demonstrated that, in the source neighboring room and living
quarter area, there is a significant noise reduction with the damping
treatment applied, whereas in the source room where air-borne sound
predominates that of structure-borne sound, the impact is not
obvious. The conclusion on effective damping treatment in the
offshore platform is made which enable acoustic professionals to
implement noise control during the design stage for offshore crews’
hearing protection and habitant comfortability.
Abstract: This study aimed at designing and developing a
mechanical force gauge for the square watermelon mold for the first
time. It also tried to introduce the square watermelon characteristics
and its production limitations. The mechanical force gauge
performance and the product itself were also described. There are
three main designable gauge models: a. hydraulic gauge, b. strain
gauge, and c. mechanical gauge. The advantage of the hydraulic
model is that it instantly displays the pressure and thus the force
exerted by the melon. However, considering the inability to measure
forces at all directions, complicated development, high cost, possible
hydraulic fluid leak into the fruit chamber and the possible influence
of increased ambient temperature on the fluid pressure, the
development of this gauge was overruled. The second choice was to
calculate pressure using the direct force a strain gauge. The main
advantage of these strain gauges over spring types is their high
precision in measurements; but with regard to the lack of conformity
of strain gauge working range with water melon growth, calculations
were faced with problems. Finally the mechanical pressure gauge has
advantages, including the ability to measured forces and pressures on
the mold surface during melon growth; the ability to display the peak
forces; the ability to produce melon growth graph thanks to its
continuous force measurements; the conformity of its manufacturing
materials with the required physical conditions of melon growth; high
air conditioning capability; the ability to permit sunlight reaches the
melon rind (no yellowish skin and quality loss); fast and
straightforward calibration; no damages to the product during
assembling and disassembling; visual check capability of the product
within the mold; applicable to all growth environments (field,
greenhouses, etc.); simple process; low costs and so forth.
Abstract: When a high DC voltage is applied to a capacitor with
strongly asymmetrical electrodes, it generates a mechanical force that
affects the whole capacitor. This phenomenon is most likely to be
caused by the motion of ions generated around the smaller of the two
electrodes and their subsequent interaction with the surrounding
medium. A method to measure this force has been devised and used.
A formula describing the force has also been derived. After
comparing the data gained through experiments with those acquired
using the theoretical formula, a difference was found above a certain
value of current. This paper also gives reasons for this difference.
Abstract: When a high DC voltage is applied to a capacitor with
strongly asymmetrical electrodes, it generates a mechanical force that
affects the whole capacitor. This is caused by the motion of ions generated around the smaller of the two electrodes and their subsequent interaction with the surrounding medium. If one of the electrodes is heated, it changes the conditions around the capacitor
and influences the process of ionisation, thus changing the value of the generated force. This paper describes these changes and gives
reasons behind them. Further the experimental results are given as proof of the ionic mechanism of the phenomenon.