Abstract: Vertical slotted walls can be used as permeable
breakwaters to provide economical and environmental protection
from undesirable waves and currents inside the port. The permeable
breakwaters are partially protection and have been suggested to
overcome the environmental disadvantages of fully protection
breakwaters. For regular waves a semi-analytical model is based on
an eigenfunction expansion method and utilizes a boundary condition
at the surface of each wall are developed to detect the energy
dissipation through the slots. Extensive laboratory tests are carried
out to validate the semi-analytic models. The structure of the physical
model contains two walls and it consists of impermeable upper and
lower part, where the draft is based a decimal multiple of the total
depth. The middle part is permeable with a porosity of 50%. The
second barrier is located at a distant of 0.5, 1, 1.5 and 2 times of the
water depth from the first one. A comparison of the theoretical results
with previous studies and experimental measurements of the present
study show a good agreement and that, the semi-analytical model is
able to adequately reproduce most the important features of the
experiment.
Abstract: The knowledge about rock layers thickness,especially above drilled mining pavements is crucial for workers safety. The measuring systems used nowadays are generally imperfect and there is a strong demand for improvement. The application of a new type of a measurement system called Self-excited Acoustical System is presentedin the paper. The system was applied until now to monitor stress changes in metal and concrete constructions. The change in measurement methodology resulted in possibility of measuring the thickness of the rocks above the tunnels as well as thickness of a singular rocklayer. The idea is to find two resonance frequencies of the self-exited system,which consists of a vibration exciter and vibration receiver placed at a distance, which are coupled with a proper power amplifier, and which operate in a closed loop with a positive feedback. The resonance with the higher amplitude determines thickness of the whole rock, whereas the lower amplitude resonance indicates thickness of a singular layer. The results of the laboratory tests conducted on a group of different rock materials are also presented.
Abstract: When dealing with safety in structures, the connections between structural components play an important role. Robustness of a structure as a whole depends both on the load- bearing capacity of the structural component and on the structures capacity to resist total failure, even though a local failure occurs in a component or a connection between components. To avoid progressive collapse it is necessary to be able to carry out a design for connections. A connection may be executed with anchors to withstand local failure of the connection in structures built with prefabricated components. For the design of these anchors, a model is developed for connections in structures performed in prefabricated autoclaved aerated concrete components. The design model takes into account the effect of anchors placed close to the edge, which may result in splitting failure. Further the model is developed to consider the effect of reinforcement diameter and anchor depth. The model is analytical and theoretically derived assuming a static equilibrium stress distribution along the anchor. The theory is compared to laboratory test, including the relevant parameters and the model is refined and theoretically argued analyzing the observed test results. The method presented can be used to improve safety in structures or even optimize the design of the connections
Abstract: Liners are made to protect the groundwater table from
the infiltration of leachate which normally carries different kinds of
toxic materials from landfills. Although these liners are engineered to
last for long period of time; unfortunately these liners fail; therefore,
toxic materials pass to groundwater. This paper focuses on the
changes of the hydraulic conductivity of a sand-bentonite liner due to
the infiltration of biofuel and ethanol fuel. Series of laboratory tests
were conducted in 20-cm-high PVC columns. Several compositions
of sand-bentonite liners were tested: 95% sand: 5% bentonite; 90%
sand: 10% bentonite; and 100% sand (passed mesh #40). The
columns were subjected to extreme pressures of 40 kPa, and 100 kPa
to evaluate the transport of alternative fuels (biofuel and ethanol
fuel). For comparative studies, similar tests were carried out using
water. Results showed that hydraulic conductivity increased due to
the infiltration of alternative fuels through the liners. Accordingly,
the increase in the hydraulic conductivity showed significant
dependency on the type of liner mixture and the characteristics of the
liquid. The hydraulic conductivity of a liner (subjected to biofuel
infiltration) consisting of 5% bentonite: 95% sand under pressure of
40 kPa and 100 kPa had increased by one fold. In addition, the
hydraulic conductivity of a liner consisting of 10% bentonite: 90%
sand under pressure of 40 kPa and 100 kPa and infiltrated by biofuel
had increased by three folds. On the other hand, the results obtained
by water infiltration under 40 kPa showed lower hydraulic
conductivities of 1.50×10-5 and 1.37×10-9 cm/s for 5% bentonite:
95% sand, and 10% bentonite: 90% sand, respectively. Similarly,
under 100 kPa, the hydraulic conductivities were 2.30×10-5 and
1.90×10-9 cm/s for 5% bentonite: 95% sand, and 10% bentonite: 90%
sand, respectively.
Abstract: Microbial-induced calcite precipitation (MICP) is a
relatively green and sustainable soil improvement technique. It
utilizes biochemical process that exists naturally in soil to improve
engineering properties of soils. The calcite precipitation process is
uplifted by the mean of injecting higher concentration of urease
positive bacteria and reagents into the soil. The main objective of this
paper is to provide an overview of the factors affecting the MICP in
soil. Several factors were identified including nutrients, bacteria type,
geometric compatibility of bacteria, bacteria cell concentration,
fixation and distribution of bacteria in soil, temperature, reagents
concentration, pH, and injection method. These factors were found to
be essential for promoting successful MICP soil treatment.
Furthermore, a preliminary laboratory test was carried out to
investigate the potential application of the technique in improving the
shear strength and impermeability of a residual soil specimen. The
results showed that both shear strength and impermeability of
residual soil improved significantly upon MICP treatment. The
improvement increased with increasing soil density.
Abstract: This study mainly aims at assessing the level of
microbial pollution of the water used in the chair system in dental
clinics. For this purpose 36 samples have been randomly collected
from a number of dental surgeries in the city of Tripoli in Libya.
However, 32 of the samples have tested positive to microbial
pollution including 13 of the samples, which have tested positives to
Pseudomonas aeruginosa. Based on the results of the test a further
investigation of the biofilms incorporated within the dental chair
system has been conducted. The laboratory tests of biofilms with
similar design to those found in dental chairs have proved that
bacterial pollution takes place through saliva of the patients who use
the chairs, and that this saliva is rich with nutrients which provides a
suitable breeding ground for all types of bacteria.
Abstract: The article presents test results on the changes
occurring in sewage sludge during the process of its storage. Tests
were conducted on mechanically dehydrated sewage sludge derived
from large municipal sewage treatment plants equipped with
biological sewage treatment systems. In testing presented in the paper
the focus was on the basic fuel properties of sewage sludge: moisture
content, heat of combustion, carbon share. In the first part of the
article the overview of the issues concerning the sewage sludge
management is presented and the genesis of tests is explained.
Further in the paper, selected results of conducted tests are discussed.
Changes in tested parameters were determined in the period of a 10-
month sewage storage.
Abstract: This paper presents an analytical method to solve
governing consolidation parabolic partial differential equation (PDE)
for inelastic porous Medium (soil) with consideration of variation of
equation coefficient under cyclic loading. Since under cyclic loads,
soil skeleton parameters change, this would introduce variable
coefficient of parabolic PDE. Classical theory would not rationalize
consolidation phenomenon in such condition. In this research, a
method based on time space mapping to a virtual time space along
with superimposing rule is employed to solve consolidation of
inelastic soils in cyclic condition. Changes of consolidation
coefficient applied in solution by modification of loading and
unloading duration by introducing virtual time. Mapping function is
calculated based on consolidation partial differential equation results.
Based on superimposing rule a set of continuous static loads in
specified times used instead of cyclic load. A set of laboratory
consolidation tests under cyclic load along with numerical
calculations were performed in order to verify the presented method.
Numerical solution and laboratory tests results showed accuracy of
presented method.
Abstract: Researchers have long had trouble in measurement of
Exchangeable Sodium Ratio (ESR) at salt-affected soils. this
parameter are often determined using laborious and time consuming
laboratory tests, but it may be more appropriate and economical to
develop a method which uses a more simple soil salinity index. The
aim of this study was to determine the relationship between
exchangeable sodium ratio (ESR) and sodium adsorption ratio (SAR)
in some salt-affected soils of Khuzestan plain. To this purpose, two
experimental areas (S1, S2) of Khuzestan province-IRAN were
selected and four treatments with three replications by series of
double rings were applied. The treatments were included 25cm,
50cm, 75cm and 100cm water application. The statistical results of
the study indicated that in order to predict soil ESR based on soil
SAR the linear regression model ESR=0.2048+0.0066 SAR
(R2=0.53) & ESR=0.0564+0.0171 SAR (R2=0.76) can be
recommended in Pilot S1 and S2 respectively.
Abstract: This paper presents the prediction of kidney
dysfunction using different neural network (NN) approaches. Self
organization Maps (SOM), Probabilistic Neural Network (PNN) and
Multi Layer Perceptron Neural Network (MLPNN) trained with Back
Propagation Algorithm (BPA) are used in this study. Six hundred and
sixty three sets of analytical laboratory tests have been collected from
one of the private clinical laboratories in Baghdad. For each subject,
Serum urea and Serum creatinin levels have been analyzed and tested
by using clinical laboratory measurements. The collected urea and
cretinine levels are then used as inputs to the three NN models in
which the training process is done by different neural approaches.
SOM which is a class of unsupervised network whereas PNN and
BPNN are considered as class of supervised networks. These
networks are used as a classifier to predict whether kidney is normal
or it will have a dysfunction. The accuracy of prediction, sensitivity
and specificity were found for each type of the proposed networks
.We conclude that PNN gives faster and more accurate prediction of
kidney dysfunction and it works as promising tool for predicting of
routine kidney dysfunction from the clinical laboratory data.
Abstract: An intuitive user interface for the teleoperation of mobile rescue robots is one key feature for a successful exploration of inaccessible and no-go areas. Therefore, we have developed a novel framework to embed a flexible and modular user interface into a complete 3-D virtual reality simulation system. Our approach is based on a client-server architecture to allow for a collaborative control of the rescue robot together with multiple clients on demand. Further, it is important that the user interface is not restricted to any specific type of mobile robot. Therefore, our flexible approach allows for the operation of different robot types with a consistent concept and user interface. In laboratory tests, we have evaluated the validity and effectiveness of our approach with the help of two different robot platforms and several input devices. As a result, an untrained person can intuitively teleoperate both robots without needing a familiarization time when changing the operating robot.
Abstract: Composite steel-concrete slabs using thin-walled
corrugated steel sheets with embossments represent a modern and
effective combination of steel and concrete. However, the design
of new types of sheeting is conditional on the execution of expensive
and time-consuming laboratory testing. The effort to develop
a cheaper and faster method has lead to many investigations all over
the world. In our paper we compare the results from our experiments
involving vacuum loading, four-point bending and small-scale shear
tests.
Abstract: One of the main issues in Computer Vision is to extract the movement of one or several points or objects of interest in an image or video sequence to conduct any kind of study or control process. Different techniques to solve this problem have been applied in numerous areas such as surveillance systems, analysis of traffic, motion capture, image compression, navigation systems and others, where the specific characteristics of each scenario determine the approximation to the problem. This paper puts forward a Computer Vision based algorithm to analyze fish trajectories in high turbulence conditions in artificial structures called vertical slot fishways, designed to allow the upstream migration of fish through obstructions in rivers. The suggested algorithm calculates the position of the fish at every instant starting from images recorded with a camera and using neural networks to execute fish detection on images. Different laboratory tests have been carried out in a full scale fishway model and with living fishes, allowing the reconstruction of the fish trajectory and the measurement of velocities and accelerations of the fish. These data can provide useful information to design more effective vertical slot fishways.
Abstract: Soft clays are defined as cohesive soil whose water
content is higher than its liquid limits. Thus, soil-cement mixing is
adopted to improve the ground conditions by enhancing the strength
and deformation characteristics of the soft clays. For the above
mentioned reasons, a series of laboratory tests were carried out to
study some fundamental mechanical properties of cement stabilized
soft clay. The test specimens were prepared by varying the portion of
ordinary Portland cement to the soft clay sample retrieved from the
test site of RECESS (Research Centre for Soft Soil). Comparisons
were made for both homogeneous and columnar system specimens
by relating the effects of cement stabilized clay of for 0, 5 and 10 %
cement and curing for 3, 28 and 56 days. The mechanical properties
examined included one-dimensional compressibility and undrained
shear strength. For the mechanical properties, both homogeneous and
columnar system specimens were prepared to examine the effect of
different cement contents and curing periods on the stabilized soil.
The one-dimensional compressibility test was conducted using an
oedometer, while a direct shear box was used for measuring the
undrained shear strength. The higher the value of cement content, the
greater is the enhancement of the yield stress and the decrease of
compression index. The value of cement content in a specimen is a
more active parameter than the curing period.
Abstract: Measurements of capacitance C and dissipation
factor tand of the stator insulation system provide useful information
about internal defects within the insulation. The index k is defined as
the proportionality constant between the changes at high voltage of
capacitance DC and of the dissipation factor Dtand . DC and
Dtand values were highly correlated when small flat defects were
within the insulation and that correlation was lost in the presence of
large narrow defects like electrical treeing. The discrimination
between small and large defects is made resorting to partial discharge
PD phase angle analysis. For the validation of the results, C and tand
measurements were carried out in a 15MVA 4160V steam turbine
turbogenerator placed in a sugar mill. In addition, laboratory test
results obtained by other authors were analyzed jointly. In such
laboratory tests, model coil bars subjected to thermal cycling resulted
highly degraded and DC and Dtand values were not correlated. Thus,
the index k could not be calculated.
Abstract: Tensile armour wires provide a flexible pipe's
resistance to longitudinal stresses. Flexible pipe manufacturers need
to know the effect of defects such as scratches and cracks, with
dimensions less than 0.2mm which is the limit of the current nondestructive
detection technology, on the fracture stress and fracture
strain of the wire for quality assurance purposes. Recent research
involving the determination of the fracture strength of cracked wires
employed laboratory testing and classical fracture mechanics
approach using non-standardised fracture mechanics specimens
because standard test specimens could not be manufactured from the
wires owing to their sizes. In this work, the effect of miniature
cracks on the fracture properties of tensile armour wires was
investigated using laboratory and finite element tensile testing
simulations with the phenomenological shear fracture model. The
investigation revealed that the presence of cracks shallower than
0.2mm is worse on the fracture strain of the wire.
Abstract: This research investigates the suitability of fuel oil in
improving gypseous soil. A detailed laboratory tests were carried-out
on two soils (soil I with 51.6% gypsum content, and soil II with
26.55%), where the two soils were obtained from Al-Therthar site
(Al-Anbar Province-Iraq).
This study examines the improvement of soil properties using the
gypsum material which is locally available with low cost to minimize
the effect of moisture on these soils by using the fuel oil. This study
was conducted on two models of the soil gypsum, from the Tharthar
area. The first model was sandy soil with Gypsum content of (51.6%)
and the second is clayey soil and the content of Gypsum is (26.55%).
The program included tests measuring the permeability and
compressibility of the soil and their collapse properties. The shear
strength of the soil and the amounts of weight loss of fuel oil due to
drying had been found. These tests have been conducted on the
treated and untreated soils to observe the effect of soil treatment on
the engineering properties when mixed with varying degrees of fuel
oil with the equivalent of the water content.
The results showed that fuel oil is a good material to modify the
basic properties of the gypseous soil of collapsibility and
permeability, which are the main problems of this soil and retained
the soil by an appropriate amount of the cohesion suitable for
carrying the loads from the structure.
Abstract: A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped C-channel. The lipped C-channels used were C07508, C07512 and C10012. The dimensions of the leg of U-bracket were 50x35 mm and 50x60 mm respectively, where 25 mm clearance was provided to the connections for specimens with clearance. Results show that specimens with and without clearance experienced the same mode of failure. Failure began with the yielding of the connectors followed by distortional buckling of the wall plate. However, when C075 sections were used as wall plate, the system behaved differently. There was a large deformation in the wall plate and failure began in the distortional buckling of the wall plate followed by bearing of the connecting plates at the supports (U-bracket). The ultimate strength of the system also decreased dramatically when C075 sections were used.
Abstract: Properly sized capacitor banks are connected across induction motors for several reasons including power factor correction, reducing distortions, increasing capacity, etc. Total harmonic distortion (THD) and power factor (PF) are used in such cases to quantify the improvements obtained through connection of the external capacitor banks. On the other hand, one of the methods for assessing the motor internal condition is by the use of Park-s pattern analysis. In spite of taking adequate precautionary measures, the capacitor banks may sometimes malfunction. Such a minor fault in the capacitor bank is often not apparently discernible. This may however, give rise to substantial degradation of power factor correction performance and may also damage the supply profile. The case is more severe with the fact that the Park-s pattern gets distorted due to such external capacitor faults, and can give anomalous results about motor internal fault analyses. The aim of this paper is to present simulation and hardware laboratory test results to have an understanding of the anomalies in harmonic distortion and Park-s pattern analyses in induction motors due to capacitor bank defects.
Abstract: A comprehensive program of laboratory testing on a
compacted kaolin in a modified triaxial cell was perform to
investigate the influence of hydraulic hysteresis on effective stress in
unsaturated soils. The test data are presented on a range of constant
suction shear tests along wetting and drying paths. The values of
effective stress parameter χ at different matric suction were
determined using the test results. The effect of hydraulic hysteresis
phenomenon on the effective stress was observed. The values of
effective stress parameter χ obtained from the experiments were
compared with those obtained from the expressions proposed in
literature.