Abstract: As seen in literature, about 70% of the improvement initiatives fail, and a significant number do not even get started. This paper analyses the problem of failing initiatives on Software Process Improvement (SPI), and proposes good practices supported by motivational tools that can help minimizing failures. It elaborates on the hypothesis that human factors are poorly addressed by deployers, especially because implementation guides usually emphasize only technical factors. This research was conducted with SPI deployers and analyses 32 SPI initiatives. The results indicate that although human factors are not commonly highlighted in guidelines, the successful initiatives usually address human factors implicitly. This research shows that practices based on human factors indeed perform a crucial role on successful implantations of SPI, proposes change management as a theoretical framework to introduce those practices in the SPI context and suggests some motivational tools based on SPI deployers experience to support it.
Abstract: An implant elicits a biological response in the
surrounding tissue which determines the acceptance and long-term
function of the implant. Dental implants have become one of the
main therapy methods in clinic after teeth lose. A successful implant
is in contact with bone and soft tissue represent by fibroblasts. In our
study we focused on the interaction between six different chemically
and physically modified titanium implants (Tis-MALP, Tis-O, Tis-
OA, Tis-OPAAE, Tis-OZ, Tis-OPAE) with alveolar fibroblasts as
well as with five type of microorganisms (S. epidermis, S.mutans, S.
gordonii, S. intermedius, C.albicans). The analysis of microorganism
adhesion was determined by CFU (colony forming unite) and biofilm
formation. The presence of α3β1 and vinculin expression on alveolar
fibroblasts was demonstrated using phospho specific cell based
ELISA (PACE). Alveolar fibroblasts have the highest expression of
these proteins on Tis-OPAAE and Tis-OPAE. It corresponds with
results from bacterial adhesion and biofilm formation and it was
related to the lowest production of collagen I by alveolar fibroblasts
on Tis-OPAAE titanium disc.
Abstract: This study aimed to present the mechanical
performance evaluation of the dynamic hip screw (DHS) for
trochanteric fracture by means of finite element method. The
analyses were performed based on stainless steel and titanium
implant material definitions at various stages of bone healing and
including implant removal. The assessment of the mechanical
performance used two parameters, von Mises stress to evaluate the
strength of bone and implant and elastic strain to evaluate fracture
stability. The results show several critical aspects of dynamic hip
screw for trochanteric fracture stabilization. In the initial stage of
bone healing process, partial weight bearing should be applied to
avoid the implant failure. In the late stage of bone healing, stainless
steel implant should be removed.
Abstract: Magnesium is used implant material potentially for
non-toxicity to the human body. Due to the excellent
bio-compatibility, Mg alloys is applied to implants avoiding removal
second surgery. However, it is found commercial magnesium alloys
including aluminum has low corrosion resistance, resulting
subcutaneous gas bubbles and consequently the approach as
permanent bio-materials. Generally, Aluminum is known to pollution
substance, and it raises toxicity to nervous system. Therefore
especially Mg-35Zn-3Ca alloy is prepared for new biodegradable
materials in this study. And the pulsed power is used in
constant-current mode of DC power kinds of anodization. Based on
the aforementioned study, it examines corrosion resistance and
biocompatibility by effect of current and frequency variation. The
surface properties and thickness were compared using scanning
electronic microscopy. Corrosion resistance was assessed via
potentiodynamic polarization and the effect of oxide layer on the body
was assessed cell viability. Anodized Mg-35Zn-3Ca alloy has good
biocompatibility in vitro by current and frequency variation.
Abstract: In this study, the Taguchi method was used to optimize the effect of HALO structure or halo implant variations on threshold voltage (VTH) and leakage current (ILeak) in 45nm p-type Metal Oxide Semiconductor Field Effect Transistors (MOSFETs) device. Besides halo implant dose, the other process parameters which used were Source/Drain (S/D) implant dose, oxide growth temperature and silicide anneal temperature. This work was done using TCAD simulator, consisting of a process simulator, ATHENA and device simulator, ATLAS. These two simulators were combined with Taguchi method to aid in design and optimize the process parameters. In this research, the most effective process parameters with respect to VTH and ILeak are halo implant dose (40%) and S/D implant dose (52%) respectively. Whereas the second ranking factor affecting VTH and ILeak are oxide growth temperature (32%) and halo implant dose (34%) respectively. The results show that after optimizations approaches is -0.157V at ILeak=0.195mA/μm.
Abstract: RFID (Radio Frequency IDentification) system has
been widely used in our life, such as transport systems, passports,
automotive, animal tracking, human implants, library, and so on.
However, the RFID authentication protocols between RF (Radio
Frequency) tags and the RF readers have been bring about various
privacy problems that anonymity of the tags, tracking, eavesdropping,
and so on. Many researchers have proposed the solution of the
problems. However, they still have the problem, such as location
privacy, mutual authentication. In this paper, we show the problems of
the previous protocols, and then we propose a more secure and
efficient RFID authentication protocol.
Abstract: According to the statistics, the prevalence of congenital hearing loss in Taiwan is approximately six thousandths; furthermore, one thousandths of infants have severe hearing impairment. Hearing ability during infancy has significant impact in the development of children-s oral expressions, language maturity, cognitive performance, education ability and social behaviors in the future. Although most children born with hearing impairment have sensorineural hearing loss, almost every child more or less still retains some residual hearing. If provided with a hearing aid or cochlear implant (a bionic ear) timely in addition to hearing speech training, even severely hearing-impaired children can still learn to talk. On the other hand, those who failed to be diagnosed and thus unable to begin hearing and speech rehabilitations on a timely manner might lose an important opportunity to live a complete and healthy life. Eventually, the lack of hearing and speaking ability will affect the development of both mental and physical functions, intelligence, and social adaptability. Not only will this problem result in an irreparable regret to the hearing-impaired child for the life time, but also create a heavy burden for the family and society. Therefore, it is necessary to establish a set of computer-assisted predictive model that can accurately detect and help diagnose newborn hearing loss so that early interventions can be provided timely to eliminate waste of medical resources. This study uses information from the neonatal database of the case hospital as the subjects, adopting two different analysis methods of using support vector machine (SVM) for model predictions and using logistic regression to conduct factor screening prior to model predictions in SVM to examine the results. The results indicate that prediction accuracy is as high as 96.43% when the factors are screened and selected through logistic regression. Hence, the model constructed in this study will have real help in clinical diagnosis for the physicians and actually beneficial to the early interventions of newborn hearing impairment.
Abstract: In recent years, there has been an increasing interest
toward the use of bovine genotyped embryos for commercial embryo
transfer programs. Biopsy of a few cells in morulla stage is essential
for preimplantation genetic diagnosis (PGD). Low amount of DNA
have limited performing the several molecular analyses within PGD
analyses. Whole genome amplification (WGA) promises to eliminate
this problem. We evaluated the possibility and performance of an
improved primer extension preamplification (I-PEP) method with a
range of starting bovine genomic DNA from 1-8 cells into the WGA
reaction. We optimized a short and simple I-PEP (ssI-PEP) procedure
(~3h). This optimized WGA method was assessed by 6 loci specific
polymerase chain reactions (PCRs), included restriction fragments
length polymorphism (RFLP). Optimized WGA procedure possesses
enough sensitivity for molecular genetic analyses through the few
input cells. This is a new era for generating characterized bovine
embryos in preimplantation stage.
Abstract: In this study, stress distributions on dental implants
made of functionally graded biomaterials (FGBM) are investigated
numerically. The implant body is considered to be subjected to axial
compression loads. Numerical problem is assumed to be 2D, and
ANSYS commercial software is used for the analysis. The cross
section of the implant thread varies as varying the height (H) and the
width (t) of the thread. According to thread dimensions of implant
and material properties of FGBM, equivalent stress distribution on
the implant is determined and presented with contour plots along
with the maximum equivalent stress values. As a result, with
increasing material gradient parameter (n), the equivalent stress
decreases, but the minimum stress distribution increases. Maximum
stress values decrease with decreasing implant radius (r). Maximum
von Mises stresses increases with decreasing H when t is constant.
On the other hand, the stress values are not affected by variation of t
in the case of H = constant.
Abstract: To understand complex living system an effort has
made by mechanical engineers and dentists to deliver prompt
products and services to patients concerned about their aesthetic look.
Since two decades various bracket systems have designed involving
techniques like milling, injection molding which are technically not
flexible for the customized dental product development. The aim of
this paper to design, develop a customized system which is
economical and mainly emphasizes the expertise design and
integration of engineering and dental fields. A custom made selfadjustable
lingual bracket and customized implants are designed and
developed using computer aided design (CAD) and rapid prototyping
technology (RPT) to improve the smiles and to overcome the
difficulties associated with conventional ones. Lengthy orthodontic
treatment usually not accepted by the patients because the patient
compliance is lost. Patient-s compliance can be improved by
facilitating faster tooth movements by designing a localized dental
vibrator using advanced engineering principles.
Abstract: This work presents an approach for the measurement
of mutual inductance on near field inductive coupling. The mutual
inductance between inductive circuits allows the simulation of energy
transfer from reader to tag, that can be used in RFID and powerless
implantable devices. It also allows one to predict the maximum
voltage in the tag of the radio-frequency system.
Abstract: The White Kwao (Pueraria mirifica), a potent phytoestrogenic medicinal plant, has long been use in Thailand as a traditional folkmedicine. However, no scientific information of the direct effect of White Kwao on the development of mammalian embryo was available. Therefore, the purpose of this study was to investigate the effect of White Kwao extract on the in vitro development and implantation rate of mouse embryos. This study was designed into two experiments. In the first experiment, the two-cell stage mouse embryos were collected from the oviduct of superovulated mature female mice, and randomly cultured in three different media, the M16, M16 supplemented with 0.52μg esthinylestradiol-17β, and M16 supplemented with 10 mg/ml White Kwao extract. The culture was incubated in CO2 incubator at 37 oC . After the embryos were cultivated, the developments of embryos were observed every 24 hours for 5 days. The development rate of embryos from the two-cell stage to blastocyst stage in the media was with White Kwao was significantly higher (p
Abstract: Various assisted reproductive techniques have been
developed and refined to obtain a large number of offspring from
genetically superior animals or obtain offspring from infertile (or
subfertile) animals. The embryo transfer is one assisted reproductive
technique developed well, aimed at increased productivity of selected
females, disease control, importation and exportation of livestock,
rapid screening of AI sires for genetically recessive characteristics,
treatment or circumvention of certain types of infertility. Embryo
transfer also is a useful research tool for evaluating fetal and maternal
interactions. This technique has been applied to nearly every species
of domestic animal and many species of wildlife and exotic animals,
including humans and non-human primates. The successful of
embryo transfers have been limited to within-animal, homologous
replacement of the embryos. There are several examples of
interspecific and intergeneric embryo transfers in which embryos
implanted but did not develop to term: sheep and goat, mouse and rat.
An immunological rejections and placental incompatibility between
the embryo and the surrogate mother appear to restrict interspecific
embryo transfer/interspecific pregnancy. Recently, preimplantation
embryo manipulation procedures have been applied, such as
technique of inner cell mass transfer. This technique will possible to
overcome the reproductive barrier interspecific embryo
transfer/interspecific pregnancy, if there is a protective mechanism
which prevents recognition of the foreign fetus by the mother of the
other species
Abstract: One of the essential requirements of a realistic
surgical simulator is to reproduce haptic sensations due to the
interactions in the virtual environment. However, the interaction need
to be performed in real-time, since a delay between the user action
and the system reaction reduces the immersion sensation. In this
paper, a prototype of a coronary stent implant simulator is present;
this system allows real-time interactions with an artery by means of a
specific haptic device. To improve the realism of the simulation, the
building of the virtual environment is based on real patients- images
and a Web Portal is used to search in the geographically remote
medical centres a virtual environment with specific features in terms
of pathology or anatomy. The functional architecture of the system
defines several Medical Centres in which virtual environments built
from the real patients- images and related metadata with specific
features in terms of pathology or anatomy are stored. The searched
data are downloaded from the Medical Centre to the Training Centre
provided with a specific haptic device and with the software
necessary both to manage the interaction in the virtual environment.
After the integration of the virtual environment in the simulation
system it is possible to perform training on the specific surgical
procedure.
Abstract: A closed-loop controlled wireless power transmission circuit block for implantable biomedical applications is described in this paper. The circuit consists of one front-end rectifier, power management sub-block including bandgap reference and low drop-out regulators (LDOs) as well as transmission power detection / feedback circuits. Simulation result shows that the front-end rectifier achieves 80% power efficiency with 750-mV single-end peak-to-peak input voltage and 1.28-V output voltage under load current of 4 mA. The power management block can supply 1.8mA average load current under 1V consuming only 12μW power, which is equivalent to 99.3% power efficiency. The wireless power transmission block described in this paper achieves a maximum power efficiency of 80%. The wireless power transmission circuit block is designed and implemented using UMC 65-nm CMOS/RF process. It occupies 1 mm × 1.2 mm silicon area.
Abstract: Physiological control of a left ventricle assist device (LVAD) is generally a complicated task due to diverse operating environments and patient variability. In this work, a tracking control algorithm based on sliding mode and feed forward control for a class of discrete-time single input single output (SISO) nonlinear uncertain systems is presented. The controller was developed to track the reference trajectory to a set operating point without inducing suction in the ventricle. The controller regulates the estimated mean pulsatile flow Qp and mean pulsatility index of pump rotational speed PIω that was generated from a model of the assist device. We recall the principle of the sliding mode control theory then we combine the feed-forward control design with the sliding mode control technique to follow the reference trajectory. The uncertainty is replaced by its upper and lower boundary. The controller was tested in a computer simulation covering two scenarios (preload and ventricular contractility). The simulation results prove the effectiveness and the robustness of the proposed controller
Abstract: A series of Ti based shape memory alloys with
composition of Ti50Ni49Cr1, Ti50Ni47Cr3 and Ti50Ni45Cr5 were
developed by vacuum arc-melting under a purified argon atmosphere.
The histometric and corrosion evaluation of Ti-Ni-Cr shape memory
alloys have been considered in this research work. The alloys were
developed by vacuum arc melting and implanted subcutaneously in
rabbits for 4, 8 and 12 weeks. Metallic implants were embedded in
order to determine the outcome of implantation on histometric and
corrosion evaluation of Ti-Ni-Cr metallic strips. Encapsulating
membrane formation around the alloys was minimal in the case of all
materials. After histomorphometric analyses it was possible to
demonstrate that there were no statistically significant differences
between the materials. Corrosion rate was also determined in this
study which is within acceptable range. The results showed the Ti-
Ni-Cr alloy was neither cytotoxic, nor have any systemic reaction on
living system in any of the test performed. Implantation shows good
compatibility and a potential of being used directly in vivo system.
Abstract: The advent of multi-million gate Field Programmable
Gate Arrays (FPGAs) with hardware support for multiplication opens
an opportunity to recreate a significant portion of the front end of a
human cochlea using this technology. In this paper we describe the
implementation of the cochlear filter and show that it is entirely
suited to a single device XC3S500 FPGA implementation .The filter
gave a good fit to real time data with efficiency of hardware usage.
Abstract: This paper presented a modified efficient inductive
powering link based on ASK modulator and proposed efficient class-
E power amplifier. The design presents the external part which is
located outside the body to transfer power and data to the implanted
devices such as implanted Microsystems to stimulate and monitoring
the nerves and muscles. The system operated with low band
frequency 10MHZ according to industrial- scientific – medical (ISM)
band to avoid the tissue heating. For external part, the modulation
index is 11.1% and the modulation rate 7.2% with data rate 1 Mbit/s
assuming Tbit = 1us. The system has been designed using 0.35-μm
fabricated CMOS technology. The mathematical model is given and
the design is simulated using OrCAD P Spice 16.2 software tool and
for real-time simulation, the electronic workbench MULISIM 11 has
been used.
Abstract: Un-doped GaN film of thickness 1.90 mm, grown on
sapphire substrate were uniformly implanted with 325 keV Mn+ ions
for various fluences varying from 1.75 x 1015 - 2.0 x 1016 ions cm-2 at
3500 C substrate temperature. The structural, morphological and
magnetic properties of Mn ion implanted gallium nitride samples
were studied using XRD, AFM and SQUID techniques. XRD of the
sample implanted with various ion fluences showed the presence of
different magnetic phases of Ga3Mn, Ga0.6Mn0.4 and Mn4N.
However, the compositions of these phases were found to be
depended on the ion fluence. AFM images of non-implanted sample
showed micrograph with rms surface roughness 2.17 nm. Whereas
samples implanted with the various fluences showed the presence of
nano clusters on the surface of GaN. The shape, size and density of
the clusters were found to vary with respect to ion fluence. Magnetic
moment versus applied field curves of the samples implanted with
various fluences exhibit the hysteresis loops. The Curie temperature
estimated from zero field cooled and field cooled curves for the
samples implanted with the fluence of 1.75 x 1015, 1.5 x 1016 and 2.0
x 1016 ions cm-2 was found to be 309 K, 342 K and 350 K
respectively.