Abstract: Transmission networks are an important part of an electric power system. The transmission lines not only have high power transmission capacity but also they are prone of larger magnitudes. Different types of faults occur in transmission lines such as single line to ground (L-G) fault, double line to ground (L-L-G) fault, line to line (L-L) fault and three phases (L-L-L) fault. These faults are needed to be cleared quickly in order to reduce damage caused to the system and they have high impact on the electrical power system equipment’s which are connected in transmission line. The main fault in transmission line is L-G fault. Therefore, protection relays are needed to protect transmission line. Overcurrent and earth fault relay is an important relay used to protect transmission lines, distribution feeders, transformers and bus couplers etc. Sometimes these relays can be used as main protection or backup protection. The modeling of protection relays is important to indicate the effects of network parameters and configurations on the operation of relays. Therefore, the modeling of overcurrent and earth fault relay is described in this paper. The overcurrent and earth fault relays with standard inverse definite minimum time are modeled and simulated by using MATLAB/Simulink software. The developed model was tested with L-G, L-L-G, L-L and L-L-L faults with various fault locations and fault resistance (0.001Ω). The simulation results are obtained by MATLAB software which shows the feasibility of analysis of transmission line protection with overcurrent and earth fault relay.
Abstract: The three-phase power system suffers from different challenging problems, e.g. voltage unbalance conditions at the load side. The voltage unbalance usually degrades the power quality of the electric power system. Several techniques can be considered for load balancing including load reconfiguration, static synchronous compensator and static reactive power compensator. In this work an efficient neural network is designed to control the unbalanced condition in the Aqaba-Qatrana-South Amman (AQSA) electric power system. It is designed for highly enhanced response time of the reactive compensator for voltage balancing. The neural network is developed to determine the appropriate set of firing angles required for the thyristor-controlled reactor to balance the three load voltages accurately and quickly. The parameters of AQSA power system are considered in the laboratory model, and several test cases have been conducted to test and validate the proposed technique capabilities. The results have shown a high performance of the proposed Neural Network Control (NNC) technique for correcting the voltage unbalance conditions at three-phase load based on accuracy and response time.
Abstract: At present, the evaluation of voltage stability
assessment experiences sizeable anxiety in the safe operation of
power systems. This is due to the complications of a strain power
system. With the snowballing of power demand by the consumers
and also the restricted amount of power sources, therefore, the system
has to perform at its maximum proficiency. Consequently, the
noteworthy to discover the maximum ability boundary prior to
voltage collapse should be undertaken. A preliminary warning can be
perceived to evade the interruption of power system’s capacity. The
effectiveness of line voltage stability indices (LVSI) is differentiated
in this paper. The main purpose of the indices used is to predict the
proximity of voltage instability of the electric power system. On the
other hand, the indices are also able to decide the weakest load buses
which are close to voltage collapse in the power system. The line
stability indices are assessed using the IEEE 14 bus test system to
validate its practicability. Results demonstrated that the implemented
indices are practically relevant in predicting the manifestation of
voltage collapse in the system. Therefore, essential actions can be
taken to dodge the incident from arising.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.
Abstract: This paper presents a nonparametric identification of
continuous-time nonlinear systems by using a Gaussian process
(GP) model. The GP prior model is trained by artificial bee colony
algorithm. The nonlinear function of the objective system is estimated
as the predictive mean function of the GP, and the confidence
measure of the estimated nonlinear function is given by the predictive
covariance of the GP. The proposed identification method is applied
to modeling of a simplified electric power system. Simulation results
are shown to demonstrate the effectiveness of the proposed method.
Abstract: Overhead electrical insulators form an important link in an electric power system. Along with the traditional insulators (i.e. glass and porcelain, etc) presently the polymeric insulators are also used world widely. These polymeric insulators are very sensitive to various environmental parameters such temperature, environmental pollution, UV-radiations, etc. which seriously effect their electrical, chemical and hydrophobic properties. The UV radiation level in the central region of Saudi Arabia is high as compared to the IEC standard for the accelerated aging of the composite insulators. Commonly used suspension type of composite EPDM (Ethylene Propylene Diene Monomer) insulator was subjected to accelerated stress aging as per modified IEC standard simulating the inland arid deserts atmospheric condition and also as per IEC-61109 standard. The hydrophobic characteristics were studied by measuring the contact angle along the insulator surface before and after the accelerated aging of the samples. It was found that EPDM insulator loses it hydrophobic properties proportional to the intensity of UV irradiations and its rate of recovery is also very low as compared to Silicone Rubber insulator.KeywordsEPDM, composite insulators, accelerated aging, hydrophobicity, contact angle.
Abstract: The genetic algorithm (GA) based solution techniques
are found suitable for optimization because of their ability of
simultaneous multidimensional search. Many GA-variants have been
tried in the past to solve optimal power flow (OPF), one of the
nonlinear problems of electric power system. The issues like
convergence speed and accuracy of the optimal solution obtained
after number of generations using GA techniques and handling
system constraints in OPF are subjects of discussion. The results
obtained for GA-Fuzzy OPF on various power systems have shown
faster convergence and lesser generation costs as compared to other
approaches. This paper presents an enhanced GA-Fuzzy OPF (EGAOPF)
using penalty factors to handle line flow constraints and load
bus voltage limits for both normal network and contingency case
with congestion. In addition to crossover and mutation rate
adaptation scheme that adapts crossover and mutation probabilities
for each generation based on fitness values of previous generations, a
block swap operator is also incorporated in proposed EGA-OPF. The
line flow limits and load bus voltage magnitude limits are handled by
incorporating line overflow and load voltage penalty factors
respectively in each chromosome fitness function. The effects of
different penalty factors settings are also analyzed under contingent
state.
Abstract: The objective of this study is to propose an observer design for nonlinear systems by using an augmented linear system derived by application of a formal linearization method. A given nonlinear differential equation is linearized by the formal linearization method which is based on Taylor expansion considering up to the higher order terms, and a measurement equation is transformed into an augmented linear one. To this augmented dimensional linear system, a linear estimation theory is applied and a nonlinear observer is derived. As an application of this method, an estimation problem of transient state of electric power systems is studied, and its numerical experiments indicate that this observer design shows remarkable performances for nonlinear systems.