Abstract: In this study, heat release performances of the three extruded-type heat sinks can be used in inverter for solar power generation were evaluated. Numbers of fins in the heat sinks (namely E-38, E-47 and E-76) were 38, 47 and 76, respectively. Heat transfer areas of them were 1.8, 1.9 and 2.8m2. The heat release performances of E-38, E-47 and E-76 heat sinks were measured as 79.6, 81.6 and 83.2%, respectively. The results of heat release performance show that the larger amount of heat transfer area the higher heat release rate. While on the other, in this experiment, variations of mass flow rates caused by different cross sectional areas of the three heat sinks may not be the major parameter of the heat release. Despite the 47.4% increment of heat transfer area of E-76 heat sink than that of E-47 one, its heat release rate was higher by only 2.0%; this suggests that its heat transfer area need to be optimized.
Abstract: Microgrids are increasingly being considered to provide electricity for the expanding energy demand in the grid distribution network and grid isolated areas. However, the technical challenges associated with the operation and controls are immense. Management of dynamic power balances, power flow, and network voltage profiles imposes unique challenges in the context of microgrids. Stability of the microgrid during both grid-connected and islanded mode is considered as the major challenge during its operation. Traditional control methods have been employed are based on the assumption of linear loads. For instance the concept of PQ, voltage and frequency control through decoupled PQ are some of very useful when considering linear loads, but they fall short when considering nonlinear loads. The deficiency of traditional control methods of microgrid suggests that more research in the control of microgrids should be done. This research aims at introducing the dq technique concept into decoupled PQ for dynamic load demand control in inverter interfaced DG system operating as isolated LV microgrid. Decoupled PQ in exact mathematical formulation in dq frame is expected to accommodate all variations of the line parameters (resistance and inductance) and to relinquish forced relationship between the DG variables such as power, voltage and frequency in LV microgrids and allow for individual parameter control (frequency and line voltages). This concept is expected to address and achieve accurate control, improve microgrid stability and power quality at all load conditions.
Abstract: Renewable Energy based microgrids are being considered to provide electricity for the expanding energy demand in the grid distribution network and grid isolated areas. The technical challenges associated with the operation and controls are immense. Electricity generation by Renewable Energy Sources is of stochastic nature such that there is a demand for regulation of voltage output in order to satisfy the standard loads’ requirements. In a renewable energy based microgrid, the energy sources give stochastically variable magnitude AC or DC voltages. AC voltage regulation of micro and mini sources pose practical challenges as well as unbearable costs. It is therefore practically and economically viable to convert the voltage outputs from stochastic AC and DC voltage sources to constant DC voltage to satisfy various DC loads including inverters which ultimately feed AC loads. This paper presents results obtained from SEPIC converter based DC bus voltage regulator as a case study for renewable energy microgrid application. Real-Time Simulation results show that upon appropriate choice of controller parameters for control of the SEPIC converter, the output DC bus voltage can be kept constant regardless of wide range of voltage variations of the source. This feature is particularly important in the situation that multiple renewable sources are to be integrated to supply a microgrid under main grid integration or isolated modes of operation.
Abstract: In this paper, we propose a sensorless backstepping control of induction motor (IM) associated with three levels neutral clamped (NPC) inverter. First, the backstepping approach is designed to steer the flux and speed variables to theirs references and to compensate the uncertainties. A Lyapunov theory is used and it demonstrates that the dynamic trajectories tracking are asymptotically stable. Second, we estimate the rotor flux and speed by using the adaptive Luenberger observer (ALO). Simulation results are provided to illustrate the performance of the proposed approach in high and low speeds and load torque disturbance.
Abstract: This paper presents a comparative study of two most popular control strategies for Induction motor (IM) drives: Field-Oriented Control (FOC) and Direct Torque Control (DTC). The comparison is based on various criteria including basic control characteristics,
dynamic performance, and implementation complexity. The study is done by simulation using the Simulink Power System Block set that allows a complete representation of the power section (inverter and IM) and the control system.
Abstract: This paper is based on the performance of the Switched Reluctance Motor (SRM) drives using Z-Source Inverter with the simplified rule base of Fuzzy Logic Controller (FLC) with the output scaling factor (SF) self-tuning mechanism are proposed. The aim of this paper is to simplify the program complexity of the controller by reducing the number of fuzzy sets of the membership functions (MFs) without losing the system performance and stability via the adjustable controller gain. ZSI exhibits both voltage-buck and voltage-boost capability. It reduces line harmonics, improves reliability, and extends output voltage range. The output SF of the controller can be tuned continuously by a gain updating factor, whose value is derived from fuzzy logic, with the plant error and error change ratio as input variables. Then the results, carried out on a four-phase 6/8 pole SRM based on the dSPACEDS1104 platform, to show the feasibility and effectiveness of the devised methods and also performance of the proposed controllers will be compared with conventional counterpart.
Abstract: This paper presents CMOS Current Mode Logic (CML) circuits for a high speed Digital to Analog Converter (DAC) using standard CMOS 65nm process. The CML circuits have the propagation delay advantage over its conventional CMOS counterparts due to smaller output voltage swing and tunable bias current. The CML circuits proposed in this paper can achieve a maximum propagation delay of only 9.3ps, which can satisfy the stringent requirement for the 5 GHz high speed DAC application. Another advantage for CML circuits is its dynamic symmetry characteristic resulting in a reduction of an additional inverter. Simulation results show that the proposed CML circuits can operate from 1.08V to 1.3V with temperature ranging from -40 to +120°C.
Abstract: This paper presents design and implements a voltage
source inverter type space vector pulse width modulation (SVPWM)
for control a speed of induction motor. This scheme leads to be able
to adjust the speed of the motor by control the frequency and
amplitude of the stator voltage, the ratio of stator voltage to
frequency should be kept constant. The fuzzy logic controller is also
introduced to the system for keeping the motor speed to be constant
when the load varies. The experimental results in testing the 0.22 kW
induction motor from no-load condition to rated condition show the
effectiveness of the proposed control scheme.
Abstract: In this study, the performance of a high-frequency arc
welding machine including a two-switch inverter is analyzed. The
control of the system is achieved using two different control
techniques i- fuzzy logic control (FLC) ii- state space averaging
based sliding control. Fuzzy logic control does not need accurate
mathematical model of a plant and can be used in nonlinear
applications. The second method needs the mathematical model of
the system. In this method the state space equations of the system are
derived for two different “on" and “off" states of the switches. The
derived state equations are combined with the sliding control rule
considering the duty-cycle of the converter. The performance of the
system is analyzed by simulating the system using SIMULINK tool
box of MATLAB. The simulation results show that fuzzy logic
controller is more robust and less sensitive to parameter variations.
Abstract: The power system network is becoming more
complex nowadays and it is very difficult to maintain the stability
of the system. Today-s enhancement of technology makes it
possible to include new energy storage devices in the electric
power system. In addition, with the aid of power electronic
devices, it is possible to independently exchange active and
reactive power flow with the utility grid. The main purpose of this
paper proposes a Proportional – Integral (PI) control based 48 –
pulse Inverter based Static Synchronous Series Compensator
(SSSC) with and without Superconducting Magnetic Energy
Storage (SMES) used for enhancing the transient stability and
regulating power flow in automatic mode. Using a test power
system through the dynamic simulation in Matlab/Simulink
platform validates the performance of the proposed SSSC with and
without SMES system.
Abstract: This paper deals with stability analysis for synchronous reluctance motors drive. Special attention is paid to the transient performance with variations in motor's parameters such as Ld and Rs. A study of the dynamic control using d-q model is presented first in order to clarify the stability of the motor drive system. Based on the experimental parameters of the synchronous reluctance motor, this paper gives some simulation results using MATLAB/SIMULINK software packages. It is concluded that the motor parameters, especially Ld, affect the estimator stability and hence the whole drive system.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical trainings,
thanks to the adjustable inverters, as the Pulse Wide Modulation
(PWM) five level inverters, which is the object of study in this
article.The authors treat the relation between the law order adopted for
a given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment).
Abstract: Due to environmental concerns, the recent regulation on automobile fuel economy has been strengthened. The market demand for efficient vehicles is growing and automakers to improve engine fuel efficiency in the industry have been paying a lot of effort. To improve the fuel efficiency, it is necessary to reduce losses or to improve combustion efficiency of the engine. VVA (Variable Valve Actuation) technology enhances the engine's intake air flow, reduce pumping losses and mechanical friction losses. And also, VVA technology is the engine's low speed and high speed operation to implement each of appropriate valve lift. It improves the performance of engine in the entire operating range. This paper presents a design procedure of DC motor and drive for VVA system and shows the validity of the design result by experimental result with prototype.
Abstract: The paper presents a space-vector pulse width modulation (SVPWM) inverter feeding a permanent-magnet synchronous motor (PMSM). The SVPWM inverter enables to feed the motor with a higher voltage with low harmonic distortions than the conventional sinusoidal PWM inverter. The control strategy of the inverter is the voltage / frequency control method, which is based on the space-vector modulation technique. The proposed PMSM drive system involving the field-oriented control scheme not only decouples the torque and flux which provides faster response but also makes the control task easy. The performance of the proposed drive is simulated. The advantages of the proposed drive are confirmed by the simulation results.
Abstract: The switching lag-time and the voltage drop across
the power devices cause serious waveform distortions and
fundamental voltage drop in pulse width-modulated inverter output.
These phenomenons are conspicuous when both the output frequency
and voltage are low. To estimate the output voltage from the PWM
reference signal it is essential to take account of these imperfections
and to correct them. In this paper, on-line compensation method is
presented. It needs three simple blocs to add at the ideal reference
voltages. This method does not require any additional hardware
circuit and off- line experimental measurement. The paper includes
experimental results to demonstrate the validity of the proposed
method. It is applied, finally, in case of indirect vector controlled
induction machine and implemented using dSpace card.
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: Application of neural networks in execution of
programmed pulse width modulation (PPWM) of a voltage source
inverter (VSI) is studied in this paper. Using the proposed method it is
possible to cancel out the desired harmonics in output of VSI in
addition to control the magnitude of fundamental harmonic,
contineously. By checking the non-trained values and a performance
index, the most appropriate neural network is proposed. It is shown
that neural networks may solve the custom difficulties of practical
utilization of PPWM such as large size of memory, complex digital
circuits and controlling the magnitude of output voltage in a discrete
manner.
Abstract: Back-to-back static synchronous compensator (BtBSTATCOM) consists of two back-to-back voltage-source converters (VSC) with a common DC link in a substation. This configuration extends the capabilities of conventional STATCOM that bidirectional active power transfer from one bus to another is possible. In this paper, VSCs are designed in quasi multi-pulse form in which GTOs are triggered only once per cycle in PSCAD/EMTDC. The design details of VSCs as well as gate switching circuits and controllers are fully represented. Regulation modes of BtBSTATCOM are verified and tested on a multi-machine power system through different simulation cases. The results presented in the form of typical time responses show that practical PI controllers are almost robust and stable in case of start-up, set-point change, and line faults.
Abstract: This paper proposes a feed-forward control in
resonant dc link inverter. The feed-forward control configuration is
based on synchronous sigma-delta modulation. The simulation
results showing the proposed technique can reject non-ideal dc bus
improving the total harmonic distortion.
Abstract: The induction hardening machines are utilized in
the industries which modify machine parts and tools needed to
achieve high ware resistance. This paper describes the model of
induction heating process design of inverter circuit and the results
of induction surface hardening of heating coil. In the design of
heating coil, the shape and the turn numbers of the coil are very
important design factors because they decide the overall operating
performance of induction heater including resonant frequency, Q
factor, efficiency and power factor. The performance will be tested
by experiments in some cases high frequency induction hardening
machine.