Abstract: An experimental and numerical study has been conducted to clarify heat transfer characteristics and effectiveness of a cross-flow heat exchanger employing staggered wing-shaped tubes at different angels of attack. The water-side Rew and the air-side Rea were at 5 x 102 and at from 1.8 x 103 to 9.7 x 103, respectively. The tubes arrangements were employed with various angles of attack θ1,2,3 from 0° to 330° at the considered Rea range. Correlation of Nu, St, as well as the heat transfer per unit pumping power (ε) in terms of Rea, design parameters for the studied bundle were presented. The temperature fields around the staggered wing-shaped tubes bundle were predicted by using commercial CFD FLUENT 6.3.26 software package. Results indicated that the heat transfer was increased by increasing the angle of attack from 0° to 45°, while the opposite was true for angles of attack from 135° to 180°. The best thermal performance and hence η of studied bundle was occurred at the lowest Rea and/or zero angle of attack. Comparisons between the experimental and numerical results of the present study and those, previously, obtained for similar available studies showed good agreements.
Abstract: The present study is concerned with the effect of
exciting boundary layer on cooling process in a gas-turbine blades.
The cooling process is numerically investigated. Observations show
cooling the first row of moving or stable blades leads to increase
their life-time. Results show that minimum temperature in cooling
line with exciting boundary layer is lower than without exciting.
Using block in cooling line of turbines' blade causes flow pattern and
stability in boundary layer changed that causes increase in heat
transfer coefficient. Results show at the location of block,
temperature of turbines' blade is significantly decreased. The k-ε
turbulence model is used.
Abstract: The paper presents an overview of environmental
issues that may be expected with nuclear desalination. The analysis
of coupling nuclear power with desalination plants indicates that
adverse marine impacts can be mitigated with alternative intake
designs or cooling systems. The atmospheric impact of desalination
may be greatly reduced through the coupling with nuclear power,
while maximizing the socio-economic benefit for both processes. The
potential for tritium contamination of the desalinated water was
reviewed. Experience with the systems and practices related to the
radiological quality of the product water, shows no examples of
cross-contamination. Furthermore, the indicators for the public
acceptance of nuclear desalination, as one of the most important
sustainability aspects of any such large project, show a positive trend.
From the data collected, a conclusion is made that nuclear
desalination should be supported by decision-makers.
Abstract: The stability of Newtonian and Non-Newtonian extending films under local or global heating or cooling conditions are considered. The thickness-averaged mass, momentum and energy equations with convective and radiative heat transfer are derived, both for Newtonian and non-Newtonian fluids (Maxwell, PTT and Giesekus models considered). The stability of the system is explored using either eigenvalue analysis or transient simulations. The results showed that the influence of heating and cooling on stability strongly depends on the magnitude of the Peclet number. Examples of stabilization or destabilization of heating or cooling are shown for Pe
Abstract: The phenomenon of global warming or climate
change has led to many environmental issues including higher
atmospheric temperatures, intense precipitation, increased
greenhouse gaseous emissions and increased indoor discomfort.
Studies have shown that bringing nature to the roof such as
constructing green roof and implementing high-reflective roof may
give positive impact in mitigating the effects of global warming and
in increasing thermal comfort sensation inside buildings. However,
no study has been conducted to compare both types of passive roof
treatments in Malaysia in order to increase thermal comfort in
buildings. Therefore, this study is conducted to investigate the effect
of green roof and white painted roof as passive roof treatment in
improving indoor comfort of Malaysian homes. This study uses an
experimental approach in which the measurements of temperatures
are conducted on the case study building. The measurements of
outdoor and indoor environments were conducted on the flat roof
with two different types of roof treatment that are green roof and
white roof. The measurement of existing black bare roof was also
conducted to act as a control for this study.
Abstract: In contrast to existing of calculation of temperature field of a profile part a blade with convective cooling which are not taking into account multi connective in a broad sense of this term, we develop mathematical models and highly effective combination (BIEM AND FDM) numerical methods from the point of view of a realization on the PC. The theoretical substantiation of these methods is proved by the appropriate theorems.
Abstract: In this paper, numerical simulation is used to
investigate the thermal performance of liquid cooling heatsink with
microchannels due to geometric arrangement. Commercial software
ICEPAK is utilized for the analysis. The considered parameters
include aspect ratio, porosity and the length and height of
microchannel. The aspect ratio varies from 3 to 16 and the length of
microchannel is 10mm, 14mm, and 18mm. The height of
microchannel is 2mm, 3mm and 4mm. It is found short channel have
better thermal efficiency than long channel at 490Pa. No matter the
length of channel the best aspect ratio is 4. It is also noted that pressure
difference at 2940Pa the best aspect ratio from 4 to 8, it means pressure
difference affect aspect ratio, effective thermal resistance at low
pressure difference but lower effective thermal resistance at high
pressure difference.
Abstract: This study experimentally and numerically investigates
motor cooling performance. The motor consists of a centrifugal fan,
two axial fans, a shaft, a stator, a rotor and a heat exchanger with 637
cooling tubes. The pressure rise-flow rate (P-Q) performance curves of
the cooling fans at 1800 rpm are tested using a test apparatus
complying with the Chinese National Standard (CNS) 2726.
Compared with the experimental measurements, the numerical
analysis results show that the P-Q performance curves of the axial fan
and centrifugal fan can be estimated within about 2% and 6%,
respectively. By using the simplified model, setting up the heat
exchanger and stator as porous media, the flow field in the motor is
calculated. By using the results of the flow field near the rotor and
stator, and subjecting the heat generation rate as a boundary condition,
the temperature distributions of the stator and rotor are also calculated.
The simulation results show that the calculated temperature of the
stator winding near the axial fans is lower by about 5% than the
measured value, and the calculated temperature of the stator core
located at the center of the stator is about 1% higher than the measured
value. Besides, discussion is made to improve the motor cooling
performance.
Abstract: In research on natural ventilation, and passive cooling
with forced convection, is essential to know how heat flows in a solid
object and the pattern of temperature distribution on their surfaces,
and eventually how air flows through and convects heat from the
surfaces of steel under roof. This paper presents some results from
running the computational fluid dynamic program (CFD) by
comparison between natural ventilation and forced convection within
roof attic that is received directly from solar radiation. The CFD
program for modeling air flow inside roof attic has been modified to
allow as two cases. First case, the analysis under natural ventilation,
is closed area in roof attic and second case, the analysis under forced
convection, is opened area in roof attic. These extend of all cases to
available predictions of variations such as temperature, pressure, and
mass flow rate distributions in each case within roof attic. The
comparison shows that this CFD program is an effective model for
predicting air flow of temperature and heat transfer coefficient
distribution within roof attic. The result shows that forced convection
can help to reduce heat transfer through roof attic and an around area
of steel core has temperature inner zone lower than natural
ventilation type. The different temperature on the steel core of roof
attic of two cases was 10-15 oK.
Abstract: The paper presents the results of the European EIE
project “Realising the potential for small scale renewable energy
sources in the home – Kyotointhehome". The project's global aim is
to inform and educate teachers, students and their families so that
they can realise the need and can assess the potential for energy
efficiency (EE) measures and renewable energy sources (RES) in
their homes. The project resources were translated and trialled by 16
partners in 10 European countries.
A web-based methodology which will enable families to assess
how RES can be incorporated into energy efficient homes was
accomplished. The web application “KYOTOINHOME" will help
the citizens to identify what they can do to help their community
meet the Kyoto target for greenhouse gas reductions and prevent
global warming. This application provides useful information on how
the citizens can use renewable energy sources in their home to
provide space heating and cooling, hot water and electricity. A
methodology for assessing heat loss in a dwelling and application of
heat pump system was elaborated and will be implemented this year.
For schools, we developed a set of practical activities concerned with
preventing climate change through using renewable energy sources.
Complementary resources will also developed in the Romanian
research project “Romania Contribution to the European Targets
Regarding the Development of Renewable Energy Sources" -
PROMES.
Abstract: This paper presents the exergy analysis of a
desalination unit using humidification-dehumidification process.
Here, this unit is considered as a thermal system with three main
components, which are the heating unit by using a solar collector, the
evaporator or the humidifier, and the condenser or the dehumidifier.
In these components the exergy is a measure of the quality or grade
of energy and it can be destroyed in them. According to the second
law of thermodynamics this destroyed part is due to irreversibilities
which must be determined to obtain the exergetic efficiency of the
system.
In the current paper a computer program has been developed using
visual basic to determine the exergy destruction and the exergetic
efficiencies of the components of the desalination unit at variable
operation conditions such as feed water temperature, outlet air
temperature, air to feed water mass ratio and salinity, in addition to
cooling water mass flow rate and inlet temperature, as well as
quantity of solar irradiance.
The results obtained indicate that the exergy efficiency of the
humidifier increases by increasing the mass ratio and decreasing the
outlet air temperature. In the other hand the exergy efficiency of the
condenser increases with the increase of this ratio and also with the
increase of the outlet air temperature.
Abstract: Gas turbine air inlet cooling is a useful method for
increasing output for regions where significant power demand and
highest electricity prices occur during the warm months. Inlet air
cooling increases the power output by taking advantage of the gas
turbine-s feature of higher mass flow rate when the compressor inlet
temperature decreases. Different methods are available for reducing
gas turbine inlet temperature. There are two basic systems currently
available for inlet cooling. The first and most cost-effective system is
evaporative cooling. Evaporative coolers make use of the evaporation
of water to reduce the gas turbine-s inlet air temperature. The second
system employs various ways to chill the inlet air. In this method, the
cooling medium flows through a heat exchanger located in the inlet
duct to remove heat from the inlet air. However, the evaporative
cooling is limited by wet-bulb temperature while the chilling can cool
the inlet air to temperatures that are lower than the wet bulb
temperature. In the present work, a thermodynamic model of a gas
turbine is built to calculate heat rate, power output and thermal
efficiency at different inlet air temperature conditions. Computational
results are compared with ISO conditions herein called "base-case".
Therefore, the two cooling methods are implemented and solved for
different inlet conditions (inlet temperature and relative humidity).
Evaporative cooler and absorption chiller systems results show that
when the ambient temperature is extremely high with low relative
humidity (requiring a large temperature reduction) the chiller is the
more suitable cooling solution. The net increment in the power output
as a function of the temperature decrease for each cooling method is
also obtained.
Abstract: This paper presents the results of the experimental
tests of the cooling performance of a 12,000-Btu/h modified air
conditioner (referred to as M-AC) that use the ground as a heat sink
of a condenser. In the tests, cooling capacity of M-AC with an
optimal length of a condensing coil as well as life expectancy of
copper coil buried underground were investigated. The lengths of
copper coil fabricated and used as condenser coil of M-AC were set
at 67, 50, 40 and 30 m whereas that of a 12,000-Btu/h conventional
split-type air conditioner (referred to as C-AC) was about 22 m. The
results showed that the ground can absorb heat rejected from a
condenser of M-AC. The coefficient of performance (COP) of C-AC
was about 2.5 whereas those of M-AC were found to be higher. It
was found that the values of COP of M-AC with condensing coils of
67, 50 and 40 m long were about 6.9, 5.5 and 3.3, respectively, while
that of 30-m-long one was found to be about 2.1. The electrical
consumptions of M-AC were found lower than that of C-AC in the
range of 11.5 – 15.5%. Additionally, life expectancy of underground
condensing coil of M-AC was found to be over 7 years.
Abstract: In this study, the effect of nanofluids on the pool film
boiling was experimentally investigated at saturated condition under
atmospheric pressure. For this purpose, four different water-based
nanofluids (Al2O3, SiO2, TiO2 and CuO) with 0.1% particle volume
fraction were prepared. To investigate the boiling heat transfer, a
cylindrical rod with high temperature was used. The rod heated up to
high temperatures was immersed into nanofluids. The center
temperature of rod during the cooling process was recorded by using
a K-type thermocouple. The quenching curves showed that the pool
boiling heat transfer was strongly dependent on the nanoparticle
materials. During the repetitive quenching tests, the cooling time
decreased and thus, the film boiling vanished. Consequently, the
primary reason of this was the change of the surface characteristics
due to the nanoparticles deposition on the rod-s surface.
Abstract: In contrast to existing methods which do not take into account multiconnectivity in a broad sense of this term, we develop mathematical models and highly effective combination (BIEM and FDM) numerical methods of calculation of stationary and quasistationary temperature field of a profile part of a blade with convective cooling (from the point of view of realization on PC). The theoretical substantiation of these methods is proved by appropriate theorems. For it, converging quadrature processes have been developed and the estimations of errors in the terms of A.Ziqmound continuity modules have been received. For visualization of profiles are used: the method of the least squares with automatic conjecture, device spline, smooth replenishment and neural nets. Boundary conditions of heat exchange are determined from the solution of the corresponding integral equations and empirical relationships. The reliability of designed methods is proved by calculation and experimental investigations heat and hydraulic characteristics of the gas turbine first stage nozzle blade.
Abstract: This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide ribbon, the magnetic responses are not uniformly distributed. To understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: In contrast to existing methods which do not take into account multiconnectivity in a broad sense of this term, we develop mathematical models and highly effective combination (BIEM and FDM) numerical methods of calculation of stationary and quasi-stationary temperature field of a profile part of a blade with convective cooling (from the point of view of realization on PC). The theoretical substantiation of these methods is proved by appropriate theorems. For it, converging quadrature processes have been developed and the estimations of errors in the terms of A.Ziqmound continuity modules have been received. For visualization of profiles are used: the method of the least squares with automatic conjecture, device spline, smooth replenishment and neural nets. Boundary conditions of heat exchange are determined from the solution of the corresponding integral equations and empirical relationships. The reliability of designed methods is proved by calculation and experimental investigations heat and hydraulic characteristics of the gas turbine first stage nozzle blade.
Abstract: Electron multiplying charge coupled devices (EMCCDs) have revolutionized the world of low light imaging by introducing on-chip multiplication gain based on the impact ionization effect in the silicon. They combine the sub-electron readout noise with high frame rates. Signal-to-noise Ratio (SNR) is an important performance parameter for low-light-level imaging systems. This work investigates the SNR performance of an EMCCD operated in Non-inverted Mode (NIMO) and Inverted Mode (IMO). The theory of noise characteristics and operation modes is presented. The results show that the SNR of is determined by dark current and clock induced charge at high gain level. The optimum SNR performance is provided by an EMCCD operated in NIMO in short exposure and strong cooling applications. In contrast, an IMO EMCCD is preferable.
Abstract: Impinging jets are used in various industrial areas as a cooling and drying technique. The current research is concerned with the means of improving the heat transfer for configurations with a minimum distance of the nozzle to the impingement surface. The impingement heat transfer is described using numerical methods over a wide range of parameters for an array of planar jets. These parameters include varying jet flow speed, width of nozzle, distance of nozzle, angle of the jet flow, velocity and geometry of the impingement surface. Normal pressure and shear stress are computed as additional parameters. Using dimensionless characteristic numbers the parameters and the results are correlated to gain generalized equations. The results demonstrate the effect of the investigated parameters on the flow.
Abstract: Convergence of power series solutions for a class of
non-linear Abel type equations, including an equation that arises
in nonlinear cooling of semi-infinite rods, is very slow inside their
small radius of convergence. Beyond that the corresponding power
series are wildly divergent. Implementation of nonlinear sequence
transformation allow effortless evaluation of these power series on
very large intervals..