Exergy Analysis of a Solar Humidification- Dehumidification Desalination Unit

This paper presents the exergy analysis of a
desalination unit using humidification-dehumidification process.
Here, this unit is considered as a thermal system with three main
components, which are the heating unit by using a solar collector, the
evaporator or the humidifier, and the condenser or the dehumidifier.
In these components the exergy is a measure of the quality or grade
of energy and it can be destroyed in them. According to the second
law of thermodynamics this destroyed part is due to irreversibilities
which must be determined to obtain the exergetic efficiency of the
system.
In the current paper a computer program has been developed using
visual basic to determine the exergy destruction and the exergetic
efficiencies of the components of the desalination unit at variable
operation conditions such as feed water temperature, outlet air
temperature, air to feed water mass ratio and salinity, in addition to
cooling water mass flow rate and inlet temperature, as well as
quantity of solar irradiance.
The results obtained indicate that the exergy efficiency of the
humidifier increases by increasing the mass ratio and decreasing the
outlet air temperature. In the other hand the exergy efficiency of the
condenser increases with the increase of this ratio and also with the
increase of the outlet air temperature.





References:
<p>[1] H. Muller-Holst &amp; W. Scholkepf,&rdquo; Multi effect humidification seawater
desalination using solar energy or waste heat- various implementation of
a new technology&rdquo;, Bavarian Center for applied Energy Research,
Munchen, Germany/324-STOH10.
[2] F. A. Van Vught, Thermodynamics and Sustainable development, The
use of exergy analysis and the reduction of irreversibility, R. L.
Cornelissen, 1997, The Netherlands.
[3] Michael J. Moran &amp; Howard N. Shapiro, Fundamentals of Engineering
Thermodynamics, John Wily &amp; Sons, Inc., USA, 2004.
[4] Adrian Bejan, Advanced Engineering Thermodynamics, John Wily &amp;
Sons, Inc., Singapore, 1988.
[5] Masanori Shukuya &amp; Abdelaziz Hammache, Introduction to the Concept
of Exergy- for a better understanding of Low-Temperature-Heating &amp;
High- Temperature-Cooling Systems, VTT Technical Research Center
of Finland, Finland, 2002.</p>