Abstract: Emissions are a consequence of electricity generation. A major option for low carbon generation, local energy systems featuring Combined Heat and Power with solar PV (CHPV) has significant potential to increase energy performance, increase resilience, and offer greater control of local energy prices while complementing the UK’s emissions standards and targets. Recent advances in dynamic modelling and simulation of buildings and clusters of buildings using the IDEAS framework have successfully validated a novel multi-vector (simultaneous control of both heat and electricity) approach to integrating the wide range of primary and secondary plant typical of local energy systems designs including CHP, solar PV, gas boilers, absorption chillers and thermal energy storage, and associated electrical and hot water networks, all operating under a single unified control strategy. Results from this work indicate through simulation that integrated control of thermal storage can have a pivotal role in optimizing system performance well beyond the present expectations. Environmental impact analysis and reporting of all energy systems including CHPV LES presently employ a static annual average carbon emissions intensity for grid supplied electricity. This paper focuses on establishing and validating CHPV environmental performance against conventional emissions values and assessment benchmarks to analyze emissions performance without and with an active thermal store in a notional group of non-domestic buildings. Results of this analysis are presented and discussed in context of performance validation and quantifying the reduced environmental impact of CHPV systems with active energy storage in comparison with conventional LES designs.
Abstract: Terms set in power purchase agreements (PPA) challenge power utility companies in balancing between the returns (from maximizing power production) and securing long term supply contracts at capped production. The production limitation set in the PPA has driven efforts to maximize profits through efficient and economic power production. In this paper, a combined industrial-scale gas turbine (GT) - absorption chiller (AC) system is considered to cool the GT air intake for reducing the plant’s heat rate (HR). This GT-AC system is optimized while considering power output limitations imposed by the PPA. In addition, the proposed formulation accounts for uncertainties in the ambient temperature using Type-2 fuzzy programming. Using the enhanced chaotic differential evolution (CEDE), the Pareto frontier was constructed and the optimization results are analyzed in detail.
Abstract: In this paper, a detailed simulation model of a solar-powered triple-effect LiBr–H2O absorption chiller is developed to supply both cooling and heating demand of a large-scale building, aiming to reduce the fossil fuel consumption and greenhouse gas emissions in building sector. TRNSYS 17 is used to simulate the performance of the system over a typical year. A combined energetic-economic-environmental analysis is conducted to determine the system annual primary energy consumption and the total cost, which are considered as two conflicting objectives. A multi-objective optimization of the system is performed using a genetic algorithm to minimize these objectives simultaneously. The optimization results show that the final optimal design of the proposed plant has a solar fraction of 72% and leads to an annual primary energy saving of 0.69 GWh and annual CO2 emissions reduction of ~166 tonnes, as compared to a conventional HVAC system. The economics of this design, however, is not appealing without public funding, which is often the case for many renewable energy systems. The results show that a good funding policy is required in order for these technologies to achieve satisfactory payback periods within the lifetime of the plant.
Abstract: Solar thermal cooling system was installed on Mechanical Research Center (MRC) Building that is located in Universitas Indonesia, Depok, Indonesia. It is the first cooling system in Indonesia that utilizes solar energy as energy input combined with natural gas; therefore, the control system must be appropriated with the climates. In order to stabilize the cooling capacity and also to maximize the use of solar energy, the system applies some controllers. Constant flow rate and on/off controller are applied for the hot water, chilled water and cooling water pumps. The hot water circulated by pump when the solar radiation is over than 400W/m2, and the chilled water is continually circulated by pump and its temperature is kept constant 7 °C by absorption chiller. The cooling water is also continually circulated until the outlet temperature of cooling tower below than 27 oC. Furthermore, the three-way valve is used to control the hot water for generate vapor on absorption chiller. The system performance using that control system is shown in this study results.
Abstract: In most existing buildings in hot climate, cooling
loads lead to high primary energy consumption and consequently
high CO2 emissions. These can be substantially decreased with
integrated renewable energy systems. Kuwait is characterized by its
dry hot long summer and short warm winter. Kuwait receives annual
total radiation more than 5280 MJ/m2 with approximately 3347 h of
sunshine. Solar energy systems consist of PV modules and parabolic
trough collectors are considered to satisfy electricity consumption,
domestic water heating, and cooling loads of an existing building.
This paper presents the results of an extensive program of energy
conservation and energy generation using integrated photovoltaic
(PV) modules and Parabolic Trough Collectors (PTC). The program
conducted on an existing institutional building intending to convert it
into a Net-Zero Energy Building (NZEB) or near net Zero Energy
Building (nNZEB). The program consists of two phases; the first
phase is concerned with energy auditing and energy conservation
measures at minimum cost and the second phase considers the
installation of photovoltaic modules and parabolic trough collectors.
The 2-storey building under consideration is the Applied Sciences
Department at the College of Technological Studies, Kuwait. Single
effect lithium bromide water absorption chillers are implemented to
provide air conditioning load to the building. A numerical model is
developed to evaluate the performance of parabolic trough collectors
in Kuwait climate. Transient simulation program (TRNSYS) is
adapted to simulate the performance of different solar system
components. In addition, a numerical model is developed to assess
the environmental impacts of building integrated renewable energy
systems. Results indicate that efficient energy conservation can play
an important role in converting the existing buildings into NZEBs as
it saves a significant portion of annual energy consumption of the
building. The first phase results in an energy conservation of about
28% of the building consumption. In the second phase, the integrated
PV completely covers the lighting and equipment loads of the
building. On the other hand, parabolic trough collectors of optimum
area of 765 m2 can satisfy a significant portion of the cooling load,
i.e about73% of the total building cooling load. The annual avoided
CO2 emission is evaluated at the optimum conditions to assess the
environmental impacts of renewable energy systems. The total annual
avoided CO2 emission is about 680 metric ton/year which confirms
the environmental impacts of these systems in Kuwait.
Abstract: There are extensive applications of lithium
bromide-water absorption chillers in industry, but the heat exchangers
corrosion and refrigerating capacity loss are very difficult to be solved.
In this paper, an experiment was conducted by using plastic heat
transfer tubes instead of copper tubes. As an example, for a lithium
bromide-water absorption chiller of refrigerating capacity of 35kW,
the correlative performance of the lithium bromide-water absorption
chiller using plastic heat transfer tubes was compared with the
traditional lithium bromide-water absorption chiller. And then the
following three aspects, i.e., heat transfer area, pipe resistance, and
safety strength, are analyzed. The results show that plastic heat
transfer tubes can be used on lithium bromide-water absorption
chillers, and its prospect is very optimistic.
Abstract: Gas turbine air inlet cooling is a useful method for
increasing output for regions where significant power demand and
highest electricity prices occur during the warm months. Inlet air
cooling increases the power output by taking advantage of the gas
turbine-s feature of higher mass flow rate when the compressor inlet
temperature decreases. Different methods are available for reducing
gas turbine inlet temperature. There are two basic systems currently
available for inlet cooling. The first and most cost-effective system is
evaporative cooling. Evaporative coolers make use of the evaporation
of water to reduce the gas turbine-s inlet air temperature. The second
system employs various ways to chill the inlet air. In this method, the
cooling medium flows through a heat exchanger located in the inlet
duct to remove heat from the inlet air. However, the evaporative
cooling is limited by wet-bulb temperature while the chilling can cool
the inlet air to temperatures that are lower than the wet bulb
temperature. In the present work, a thermodynamic model of a gas
turbine is built to calculate heat rate, power output and thermal
efficiency at different inlet air temperature conditions. Computational
results are compared with ISO conditions herein called "base-case".
Therefore, the two cooling methods are implemented and solved for
different inlet conditions (inlet temperature and relative humidity).
Evaporative cooler and absorption chiller systems results show that
when the ambient temperature is extremely high with low relative
humidity (requiring a large temperature reduction) the chiller is the
more suitable cooling solution. The net increment in the power output
as a function of the temperature decrease for each cooling method is
also obtained.
Abstract: The excessive consumption of fossil energies (electrical energy) during summer caused by the technological development involves more and more climate warming.
In order to reduce the worst impact of gas emissions produced from classical air conditioning, heat driven solar absorption chiller is pretty promising; it consists on using solar as motive energy which is clean and environmentally friendly to provide cold.
Solar absorption machine is composed by four components using Lithium Bromide /water as a refrigerating couple. LiBr- water is the most promising in chiller applications due to high safety, high volatility ratio, high affinity, high stability and its high latent heat. The lithium bromide solution is constitute by the salt lithium bromide which absorbs water under certain conditions of pressure and temperature however if the concentration of the solution is high in the absorption chillers; which exceed 70%, the solution will crystallize.
The main aim of this article is to study the phenomena of the crystallization and to evaluate how the dependence between the electric conductivity and the concentration which should be controlled.