Abstract: Growing world population has fundamental impacts
and often catastrophic on natural habitat. The immethodical
consumption of energy, destruction of the forests and extinction of
plant and animal species are the consequence of this experience.
Urban sustainability and sustainable urban development, that is so
spoken these days, should be considered as a strategy, goal and
policy, beyond just considering environmental issues and protection.
The desert-s climate has made a bunch of problems for its residents.
Very hot and dry climate in summers of the Iranian desert areas,
when there was no access to modern energy source and mechanical
cooling systems in the past, made Iranian architects to design a
natural ventilation system in their buildings. The structure, like a
tower going upward the roof, besides its ornamental application and
giving a beautiful view to the building, was used as a spontaneous
ventilation system. In this paper, it has been tried to name the
problems of the area and it-s inconvenience, then some answers has
pointed out in order to solve the problems and as an alternative
solution BADGIR (wind-catcher) has been introduced as a solution
knowing that it has been playing a major role in dealing with the
problems.
Abstract: Among the chemicals used for ammunition production, TNT (Trinitrotoluene) play a significant role since World War I and II. Various types of military weapon utilize TNT in casting process. However, the TNT casting process for warhead is difficult to control the cooling rate of the liquid TNT. This problem occurs because the casting process lacks the equipment to detect the temperature during the casting procedure This study presents the temperature detected by infrared camera to illustrate the cooling rate and cooling zone of curing, and demonstrates the optimization of TNT condition to reduce the risk of air gap occurred in the warhead which can result in the destruction afterward. Premature initiation of explosive-filled projectiles in response to set-back forces during gunfiring cause by casting defects. Finally the study can help improving the process of the TNT casting. The operators can control the curing of TNT inside the case by rising up the heating rod at the proper time. Consequently this can reduce tremendous time of rework if the air gaps occur and increase strength to lower elastic modulus. Therefore, it can be clearly concluded that the use of Infrared Cameras in this process is another method to improve the casting procedure.
Abstract: A way of achieving nanodimentional structural elements in high carbon steel by special kind of heat treatment and cold plastic deformation is being explored. This leads to increasing interlamellar spacing of ferrite-carbide mixture. Decreasing the interlamellar spacing with cooling temperature increasing is determined. Experiments confirm such interlamellar spacing with which high carbon steel demonstrates the highest treatment and hardening capability. Total deformation degree effect on interlamellar spacing value in a ferrite-carbide mixture is obtained. Mechanical experiments results show that high carbon steel after heat treatment and repetitive cold plastic deformation possesses high tensile strength and yield strength keeping good percentage elongation.
Abstract: This article experimentally investigates the
thermal performance of thermoelectric air-cooling module
which comprises a thermoelectric cooler (TEC) and an
air-cooling heat sink. The influences of input current and heat
load are determined. And performances under each situation
are quantified by thermal resistance analysis. Since TEC
generates Joule heat, this nature makes construction of thermal
resistance network difficult. To simplify the analysis, this
article emphasizes on the resistance heat load might meet when
passing through the device. Therefore, the thermal resistances
in this paper are to divide temperature differences by heat load.
According to the result, there exists an optimum input current
under every heating power. In this case, the optimum input
current is around 6A or 7A. The performance of the heat sink
would be improved with TEC under certain heating power and
input current, especially at a low heat load. According to the
result, the device can even make the heat source cooler than the
ambient. However, TEC is not always effective at every heat
load and input current. In some situation, the device works
worse than the heat sink without TEC. To determine the
availability of TEC, this study figures out the effective
operating region in which the TEC air-cooling module works
better than the heat sink without TEC. The result shows that
TEC is more effective at a lower heat load. If heat load is too
high, heat sink with TEC will perform worse than without TEC.
The limit of this device is 57W. Besides, TEC is not helpful if
input current is too high or too low. There is an effective range
of input current, and the range becomes narrower when the heat
load grows.
Abstract: The main focus of the work was concerned with hydrodynamic and thermal analysis of the plate heat exchanger channel with corrugation patterns suggested to be triangular, sinusoidal, and square corrugation. This study was to numerically model and validate the triangular corrugated channel with dimensions/parameters taken from open literature, and then model/analyze both sinusoidal, and square corrugated channel referred to the triangular model. Initially, 2D modeling with local extensive analysis for triangular corrugated channel was carried out. By that, all local pressure drop, wall shear stress, friction factor, static temperature, heat flux, Nusselt number, and surface heat coefficient, were analyzed to interpret the hydrodynamic and thermal phenomena occurred in the flow. Furthermore, in order to facilitate confidence in this model, a comparison between the values predicted, and experimental results taken from literature for almost the same case, was done. Moreover, a holistic numerical study for sinusoidal and square channels together with global comparisons with triangular corrugation under the same condition, were handled. Later, a comparison between electric, and fluid cooling through varying the boundary condition was achieved. The constant wall temperature and constant wall heat flux boundary conditions were employed, and the different resulted Nusselt numbers as a consequence were justified. The results obtained can be used to come up with an optimal design, a 'compromise' between heat transfer and pressure drop.
Abstract: In a nuclear reactor Loss of Coolant accident (LOCA)
considers wide range of postulated damage or rupture of pipe in the
heat transport piping system. In the case of LOCA with/without
failure of emergency core cooling system in a Pressurised Heavy
water Reactor, the Pressure Tube (PT) temperature could rise
significantly due to fuel heat up and gross mismatch of the heat
generation and heat removal in the affected channel. The extent and
nature of deformation is important from reactor safety point of view.
Experimental set-ups have been designed and fabricated to simulate
ballooning (radial deformation) of PT for 220 MWe IPHWRs.
Experiments have been conducted by covering the CT by ceramic
fibers and then by submerging CT in water of voided PTs. In both
the experiments, it is observed that ballooning initiates at a
temperature around 665´┐¢C and complete contact between PT and
Caldaria Tube (CT) occurs at around 700´┐¢C approximately. The
strain rate is found to be 0.116% per second. The structural integrity
of PT is retained (no breach) for all the experiments. The PT heatup
is found to be arrested after the contact between PT and CT, thus
establishing moderator acting as an efficient heat sink for IPHWRs.
Abstract: The aim of the present work is to study the effect of annealing on the vibration damping capacity of high-chromium (16%) ferromagnetic steel. The alloys were prepared from raw materials of 99.9% purity melted in a high frequency induction furnace under high vacuum. The samples were heat-treated in vacuum at various temperatures (800 to 1200ºC) for 1 hour followed by slow cooling (120ºC/h). The inverted torsional pendulum method was used to evaluate the vibration damping capacity. The results indicated that the vibration damping capacity of the alloys is influenced by annealing and there exists a critical annealing temperature after 1000ºC. The damping capacity increases quickly below the critical temperature since the magnetic domains move more easily.
Abstract: In this paper, in order to investigate the effects of
photovoltaic system introduction to detached houses in Japan, two
kinds of works were done. Firstly, the hourly generation amount of a
4.2kW photovoltaic system were simulated in 46 cities to investigate
the potential of the system in different regions in Japan using a
simulation model of photovoltaic system. Secondly, based on the
simulated electricity generation amount, the energy saving, the
environmental and the economic effect of the photovoltaic system
were examined from hourly to annual timescales, based upon
calculations of typical electricity, heating, cooling and hot water
supply load profiles for Japanese dwellings. The above analysis was
carried out using a standard year-s hourly weather data for the
different city provided by the Expanded AMeDAS Weather Data
issued by AIJ (Architectural Institute of Japan).
Abstract: Thermal behavior of fuel channel under loss of coolant accident (LOCA) is a major concern for nuclear reactor safety. LOCA along with failure of emergency cooling water system (ECC) may leads to mechanical deformations like sagging and ballooning. In order to understand the phenomenon an experiment has been carried out using 19 pin fuel element simulator. Main purpose of the experiment was to trace temperature profiles over the pressure tube, calandria tube and clad tubes of Indian Pressurized Heavy Water Reactor (IPHWR) under symmetrical and asymmetrical heat-up conditions. For simulating the fully voided scenario, symmetrical heating of pressure was carried out by injecting 13.2 KW (2 % of nominal power) to all the 19 pins and the temperatures of pressure tube, calandria tube and clad tubes were measured. During symmetrical heating the sagging of fuel channel was initiated at 460 °C and the highest temperature attained by PT was 650 °C . The decay heat from clad tubes was dissipated to moderator mainly by radiation and natural convection. The highest temperature of 680 °C was observed over the outer ring of clad tubes of fuel simulator. Again, to simulate partially voided condition, asymmetrical heating of pressure was carried out by supplying 8.0 kW power to upper 8 pins of fuel simulator and temperature profiles were measured. Along the circumference of pressure tube (PT) the highest temperature difference of 320 °C was observed, which highlights the magnitude of thermal stresses under partially voided conditions.
Abstract: Oxygen and carbon isotopes records of multi-species planktonic, benthic foraminifera and bulk carbonate sample from Central Java Indonesia demonstrate that warm sea surface temperature occurred during the Miocene. Planktonic δ18O values from this study consistently lighter (-4 to -3 ‰PDB) than previous studies that indicate sea surface temperature during Miocene in this area was warm than tropical/equatorial localities. A surprising decrease of oxygen isotopic composition was recorded at ±14 Ma where the maximum of δ18O values is -4.87 ‰PDB for Orbulina universa, -5.02 ‰PDB for Globigerinoides sacculifer and -4.30 ‰PDB for Globoquadrina dehiscens, this event we predict as Middle Miocene Optimum. Warming of sea surface temperature we interpret as related to the development of Western Pacific Warm Pool where warm water from Pacific Ocean through the Indonesian seaway appears to remain during Miocene. Our result also show increasing suddenly of oxygen isotope values of planktic, benthic and bulk carbonate sample from ± 12 Ma, the increasing cooled surface water relatively high degree with Late Miocene global cooling climate or we predict that due to closing of Indonesian Gateway.
Abstract: The aim of the current study is to develop a numerical
tool that is capable of achieving an optimum shape and design of
hyperbolic cooling towers based on coupling a non-linear finite
element model developed in-house and a genetic algorithm
optimization technique. The objective function is set to be the
minimum weight of the tower. The geometric modeling of the tower
is represented by means of B-spline curves. The finite element
method is applied to model the elastic buckling behaviour of a tower
subjected to wind pressure and dead load. The study is divided into
two main parts. The first part investigates the optimum shape of the
tower corresponding to minimum weight assuming constant
thickness. The study is extended in the second part by introducing the
shell thickness as one of the design variables in order to achieve an
optimum shape and design. Design, functionality and practicality
constraints are applied.
Abstract: Powder of La0.6Sr0.4CoO3-α (LSCO) was synthesized
by a combined citrate-EDTA method. The as-synthesized LSCO
powder was calcined, respectively at temperatures of 800, 900 and
1000 °C with different heating/cooling rates which are 2, 5, 10 and
15 °C min-1. The effects of heat treatments on the phase formation of
perovskite phase of LSCO were investigated by powder X-ray
diffraction (XRD). The XRD patterns revealed that the rate of
5 °C min-1 is the optimum heating/cooling rate to obtain a single
perovskite phase of LSCO with calcination temperature of 800 °C.
This result was confirmed by a thermogravimetric analysis (TGA) as
it showed a complete decomposition of intermediate compounds to
form oxide material was also observed at 800 °C.
Abstract: The present study is concerned with effect of exciting
boundary layer on increase in heat transfer from flat surfaces. As any
increase in heat transfer between a fluid inside a face and another one
outside of it can cause an increase in some equipment's efficiency, so
at this present we have tried to increase the wall's heat transfer
coefficient by exciting the fluid boundary layer. By a collision
between flow and the placed block at the fluid way, the flow pattern
and the boundary layer stability will change. The flow way inside the
channel is simulated as a 2&3-dimensional channel by Gambit
TM
software.
With studying the achieved results by this simulation for the flow
way inside the channel with a block coordinating with Fluent
TM
software, it's determined that the figure and dimensions of the exciter
are too important for exciting the boundary layer so that any increase
in block dimensions in vertical side against the flow and any
reduction in its dimensions at the flow side can increase the average
heat transfer coefficient from flat surface and increase the flow
pressure loss. Using 2&3-dimensional analysis on exciting the flow at
the flow way inside a channel by cylindrical block at the same time
with the external flow, we came to this conclusion that the heat flux
transferred from the surface, is increased considerably in terms of the
condition without excitation. Also, the k-e turbulence model is used.
Abstract: Natural ventilation is an important means to improve indoor thermal comfort and reduce the energy consumption. A solar chimney system is an enhancing natural draft device, which uses solar radiation to heat the air inside the chimney, thereby converting the thermal energy into kinetic energy. The present study considered some parameters such as chimney width and solar intensity, which were believed to have a significant effect on space ventilation. Fluent CFD software was used to predict buoyant air flow and flow rates in the cavities. The results were compared with available published experimental and theoretical data from the literature. There was an acceptable trend match between the present results and the published data for the room air change per hour, ACH. Further, it was noticed that the solar intensity has a more significant effect on ACH.
Abstract: This paper presents the development of low cost Nano membrane fabrication system. The system is specially designed for anodic aluminum oxide membrane. This system is capable to perform the processes such as anodization and electro-polishing. The designed machine was successfully tested for 'mild anodization' (MA) for 48 hours and 'hard anodization' (HA) for 3 hours at constant 0oC. The system is digitally controlled and guided for temperature maintenance during anodization and electro-polishing. The total cost of the developed machine is 20 times less than the multi-cooling systems available in the market which are generally used for this purpose.
Abstract: Passive systems were born with the purpose of the
greatest exploitation of solar energy in cold climates and high
altitudes. They spread themselves until the 80-s all over the world
without any attention to the specific climate and the summer
behavior; this caused the deactivation of the systems due to a series
of problems connected to the summer overheating, the complex
management and the rising of the dust.
Until today the European regulation limits only the winter
consumptions without any attention to the summer behavior but, the
recent European EN 15251 underlines the relevance of the indoor
comfort, and the necessity of the analytic studies validation by
monitoring case studies.
In the porpose paper we demonstrate that the solar wall is an
efficient system both from thermal comfort and energy saving point
of view and it is the most suitable for our temperate climates because
it can be used as a passive cooling sistem too. In particular the paper
present an experimental and numerical analisys carried out on a case
study with nine different solar passive systems in Ancona, Italy.
We carried out a detailed study of the lodging provided by the
solar wall by the monitoring and the evaluation of the indoor
conditions.
Analyzing the monitored data, on the base of recognized models
of comfort (ISO, ASHRAE, Givoni-s BBCC), is emerged that the
solar wall has an optimal behavior in the middle seasons. In winter
phase this passive system gives more advantages in terms of energy
consumptions than the other systems, because it gives greater heat
gain and therefore smaller consumptions. In summer, when outside
air temperature return in the mean seasonal value, the indoor comfort
is optimal thanks to an efficient transversal ventilation activated from
the same wall.
Abstract: As the data-driven economy is growing faster than
ever and the demand for energy is being spurred, we are facing
unprecedented challenges of improving energy efficiency in data
centers. Effectively maximizing energy efficiency or minimising the
cooling energy demand is becoming pervasive for data centers. This
paper investigates overall energy consumption and the energy
efficiency of cooling system for a data center in Finland as a case
study. The power, cooling and energy consumption characteristics
and operation condition of facilities are examined and analysed.
Potential energy and cooling saving opportunities are identified and
further suggestions for improving the performance of cooling system
are put forward. Results are presented as a comprehensive evaluation
of both the energy performance and good practices of energy
efficient cooling operations for the data center. Utilization of an
energy recovery concept for cooling system is proposed. The
conclusion we can draw is that even though the analysed data center
demonstrated relatively high energy efficiency, based on its power
usage effectiveness value, there is still a significant potential for
energy saving from its cooling systems.
Abstract: In this paper a polymer electrolyte membrane (PEM)
fuel cell power system including burner, steam reformer, heat
exchanger and water heater has been considered to meet the
electrical, heating, cooling and domestic hot water loads of
residential building which in Tehran. The system uses natural gas as
fuel and works in CHP mode. Design and operating conditions of a
PEM fuel cell system is considered in this study. The energy
requirements of residential building and the number of fuel cell
stacks to meet them have been estimated. The method involved
exergy analysis and entropy generation thorough the months of the
year. Results show that all the energy needs of the building can be
met with 12 fuel cell stacks at a nominal capacity of 8.5 kW. Exergy
analysis of the CHP system shows that the increase in the ambient air
temperature from 1oC to 40oC, will have an increase of entropy
generation by 5.73%.Maximum entropy generates for 15 hour in 15th
of June and 15th of July is estimated to amount at 12624 (kW/K).
Entropy generation of this system through a year is estimated to
amount to 1004.54 GJ/k.year.
Abstract: At present, the tendency to implement the conditionbased
maintenance (CBM), which allows the optimization of the
expenses for equipment monitoring, is more and more evident; also,
the transformer substations with remote monitoring are increasingly
used. This paper reviews all the advantages of the on-line monitoring
and presents an equipment for on-line monitoring of bushings, which
is the own contribution of specialists who are the authors of this
paper. The paper presents a study of the temperature field, using the
finite element method. For carrying out this study, the 3D modelling
of the above mentioned bushing was performed. The analysis study is
done taking into account the extreme thermal stresses, focusing at the
level of the first cooling wing section of the ceramic insulator. This
fact enables to justify the tanδ variation in time, depending on the
transformer loading and the environmental conditions. With a view
to reducing the variation of dielectric losses in bushing insulation, the
use of ferrofuids instead of mineral oils is proposed.
Abstract: Accurate and comprehensive thermodynamic properties of pure and mixture of refrigerants are in demand by both producers and users of these materials. Information about thermodynamic properties is important initially to qualify potential candidates for working fluids in refrigeration machinery. From practical point of view, Refrigerants and refrigerant mixtures are widely used as working fluids in many industrial applications, such as refrigerators, heat pumps, and power plants The present work is devoted to evaluating seven cubic equations of state (EOS) in predicting gas and liquid phase volumetric properties of nine ozone-safe refrigerants both in super and sub-critical regions. The evaluations, in sub-critical region, show that TWU and PR EOS are capable of predicting PVT properties of refrigerants R32 within 2%, R22, R134a, R152a and R143a within 1% and R123, R124, R125, TWU and PR EOS's, from literature data are 0.5% for R22, R32, R152a, R143a, and R125, 1% for R123, R134a, and R141b, and 2% for R124. Moreover, SRK EOS predicts PVT properties of R22, R125, and R123 to within aforementioned errors. The remaining EOS's predicts volumetric properties of this class of fluids with higher errors than those above mentioned which are at most 8%.In general, the results are in favor of the preference of TWU and PR EOS over other remaining EOS's in predicting densities of all mentioned refrigerants in both super and sub critical regions. Typically, this refrigerant is known to offer advantages such as ozone depleting potential equal to zero, Global warming potential equal to 140, and no toxic.