Abstract: The research study evaluated the performance of
irrigation system by using special scientific tools like Remote
Sensing and GIS technology, so that proper measurements could be
taken for the sustainable agriculture and water management.
Different performance evaluation parameters had been calculated for
the purposed data was gathered from field investigation and different
government and private organizations. According to the calculations,
organic matter ranges from 0.19% (low value) to 0.76% (high value).
In flat irrigation system for wheat yield ranges from 3347.16 to
5260.39 kg/ha, while the total water applied to wheat crop ranges
from 252.94 to 279.19 mm and WUE ranges from 13.07 to 18.37
kg/ha/mm. For rice yield ranges from 3347.47 to 5433.07 kg/ha with
total water supplied to rice crop ranges from 764.71 to 978.15 mm
and WUE ranges from 3.49 to 5.71 kg/ha/mm. Similarly, in raised
bed system wheat yield ranges from 4569.13 to 6008.60 kg/ha, total
water supplied ranges from 158.87 to 185.09 mm and WUE ranges
from 27.20 to 33.54 kg/ha/mm while in rice crop, yield ranges from
5285.04 to 6716.69 kg/ha, total water supplied ranges from 600.72 to
755.06 mm and WUE ranges from 6.41 to 10.05 kg/ha/mm. Almost
51.3% water saving is observed in bed irrigation system as compared
to flat system. Less water supplied to beds is more affective as its
WUE value is higher than flat system where more water is supplied
in both the seasons. Similarly, RWS values show that maximum
water deficit while minimum area is getting adequate water supply.
Greater yield is recorded in bed system as plant per square meter is
more in bed system in comparison of flat system Thus, the integration
of GIS tools to regularly compute performance indices could provide
irrigation managers with the means for managing efficiently the
irrigation system.
Abstract: This study deals with Computational Fluid Dynamics
(CFD) studies of the interactions between the air flow and louvered
fins which equipped the automotive heat exchangers. 3D numerical
simulation results are obtained by using the ANSYS Fluent 13.0 code
and compared to experimental data. The paper studies the effect of
louver angle and louver pitch geometrical parameters, on overall
thermal hydraulic performances of louvered fins.
The comparison between CFD simulations and experimental data
show that established 3-D CFD model gives a good agreement. The
validation agrees, with about 7% of deviation respectively of friction
and Colburn factors to experimental results. As first, it is found that
the louver angle has a strong influence on the heat transfer rate. Then,
louver angle and louver pitch variation of the louvers and their effects
on thermal hydraulic performances are studied. In addition to this
study, it is shown that the second half of the fin takes has a
significant contribution on pressure drop increase without any
increase in heat transfer.
Abstract: This paper aims to present the main instruments used
in the economic literature for measuring the price risk, pointing out
on the advantages brought by the conditional variance in this respect.
The theoretical approach will be exemplified by elaborating an
EGARCH model for the price returns of wheat, both on Romanian
and on international market. To our knowledge, no previous
empirical research, either on price risk measurement for the
Romanian markets or studies that use the ARIMA-EGARCH
methodology, have been conducted. After estimating the
corresponding models, the paper will compare the estimated
conditional variance on the two markets.
Abstract: A transient finite element model has been developed
to study the heat transfer and fluid flow during spot Gas Tungsten
Arc Welding (GTAW) on stainless steel. Temperature field, fluid
velocity and electromagnetic fields are computed inside the cathode,
arc-plasma and anode using a unified MHD formulation. The
developed model is then used to study the influence of different
helium-argon gas mixtures on both the energy transferred to the
workpiece and the time evolution of the weld pool dimensions. It is
found that the addition of helium to argon increases the heat flux
density on the weld axis by a factor that can reach 6.5. This induces
an increase in the weld pool depth by a factor of 3. It is also found
that the addition of only 10% of argon to helium decreases
considerably the weld pool depth, which is due to the electrical
conductivity of the mixture that increases significantly when argon is
added to helium.
Abstract: This paper presented a modified efficient inductive
powering link based on ASK modulator and proposed efficient class-
E power amplifier. The design presents the external part which is
located outside the body to transfer power and data to the implanted
devices such as implanted Microsystems to stimulate and monitoring
the nerves and muscles. The system operated with low band
frequency 10MHZ according to industrial- scientific – medical (ISM)
band to avoid the tissue heating. For external part, the modulation
index is 11.1% and the modulation rate 7.2% with data rate 1 Mbit/s
assuming Tbit = 1us. The system has been designed using 0.35-μm
fabricated CMOS technology. The mathematical model is given and
the design is simulated using OrCAD P Spice 16.2 software tool and
for real-time simulation, the electronic workbench MULISIM 11 has
been used.
Abstract: TUSAT is a prospective Turkish
Communication Satellite designed for providing mainly data
communication and broadcasting services through Ku-Band
and C-Band channels. Thermal control is a vital issue in
satellite design process. Therefore, all satellite subsystems and
equipments should be maintained in the desired temperature
range from launch to end of maneuvering life. The main
function of the thermal control is to keep the equipments and
the satellite structures in a given temperature range for various
phases and operating modes of spacecraft during its lifetime.
This paper describes the thermal control design which uses
passive and active thermal control concepts. The active
thermal control is based on heaters regulated by software via
thermistors. Alternatively passive thermal control composes of
heat pipes, multilayer insulation (MLI) blankets, radiators,
paints and surface finishes maintaining temperature level of
the overall carrier components within an acceptable value.
Thermal control design is supported by thermal analysis using
thermal mathematical models (TMM).
Abstract: This paper presents a new circuit arrangement for a
current-mode Wheatstone bridge that is suitable for low-voltage
integrated circuits implementation. Compared to the other proposed
circuits, this circuit features severe reduction of the elements number,
low supply voltage (1V) and low power consumption (
Abstract: The atmospheric pressure plasma torch with a direct
current arc discharge stabilized by water vapor vortex was
experimentally investigated. Overheated up to 450K water vapor was
used as plasma forming gas. Plasma torch design is one of the most
important factors leading to a stable operation of the device. The
electrical and thermal characteristics of the plasma torch were
determined during the experimental investigations. The design and
the basic characteristics of the water vapor plasma torch are presented
in the paper.
Plasma torches with the electric arc stabilized by water vapor
vortex provide special performance characteristics in some plasma
processing applications such as thermal plasma neutralization and
destruction of organic wastes enabling to extract high caloric value
synthesis gas as by-product of the process. Syngas could be used as a
surrogate fuel partly replacing the dependence on the fossil fuels or
used as a feedstock for hydrogen, methanol production.
Abstract: Cooktop burners are widely used nowadays. In
cooktop burner design, nozzle efficiency and greenhouse
gas(GHG) emissions mainly depend on heat transfer from the
premixed flame to the impinging surface. This is a complicated
issue depending on the individual and combined effects of various
input combustion variables. Optimal operating conditions for
sustainable burner design were rarely addressed, especially in the
case of multiple slot-jet burners. Through evaluating the optimal
combination of combustion conditions for a premixed slot-jet
array, this paper develops a practical approach for the sustainable
design of gas cooktop burners. Efficiency, CO and NOx emissions
in respect of an array of slot jets using premixed flames were
analysed. Response surface experimental design were applied to
three controllable factors of the combustion process, viz.
Reynolds number, equivalence ratio and jet-to-vessel distance.
Desirability Function Approach(DFA) is the analytic technique
used for the simultaneous optimization of the efficiency and
emission responses.
Abstract: Chemical detection is still a continuous challenge when
it comes to designing single-walled carbon nanotube (SWCNT)
sensors with high selectivity, especially in complex chemical
environments. A perfect example of such an environment would be in
thermally oxidized soybean oil. At elevated temperatures, oil oxidizes
through a series of chemical reactions which results in the formation of
monoacylglycerols, diacylglycerols, oxidized triacylglycerols, dimers,
trimers, polymers, free fatty acids, ketones, aldehydes, alcohols,
esters, and other minor products. In order to detect the rancidity of
oxidized soybean oil, carbon nanotube chemiresistor sensors have
been coated with polyethylenimine (PEI) to enhance the sensitivity
and selectivity. PEI functionalized SWCNTs are known to have a high
selectivity towards strong electron withdrawing molecules. The
sensors were very responsive to different oil oxidation levels and
furthermore, displayed a rapid recovery in ambient air without the
need of heating or UV exposure.
Abstract: The study and development of an innovative material
for building insulation is really important for a sustainable society in order to improve comfort and reducing energy consumption. The aim of this work is the development of insulating panels for
sustainable buildings based on an innovative material made by
cardboard and Phase Change Materials (PCMs).
The research has consisted in laboratory tests whose purpose has been the obtaining of the required properties for insulation panels: lightweight, porous structures and mechanical resistance. PCMs have been used for many years in the building industry as
smart insulation technology because of their properties of storage and release high quantity of latent heat at useful specific temperatures [1]- [2].
The integration of PCMs into cellulose matrix during the waste paper recycling process has been developed in order to obtain a
composite material.
Experiments on the productive process for the realization of insulating panels were done in order to make the new material
suitable for building application. The addition of rising agents
demonstrated the possibility to obtain a lighter structure with better
insulation properties.
Several tests were conducted to verify the new panel properties. The results obtained have shown the possibility to realize an
innovative and sustainable material suitable to replace insulating panels currently used.
Abstract: A numerical study is presented on convective heat transfer in enclosures. The results are addressed to automotive headlights containing new-age light sources like Light Emitting Diodes (LED). The heat transfer from the heat source (LED) to the enclosure walls is investigated for mixed convection as interaction of the forced convection flow from an inlet and an outlet port and the natural convection at the heat source. Unlike existing studies, inlet and outlet port are thermally coupled and do not serve to remove hot fluid. The input power of the heat source is expressed by the Rayleigh number. The internal position of the heat source, the aspect ratio of the enclosure, and the inclination angle of one wall are varied. The results are given in terms of the global Nusselt number and the enclosure Nusselt number that characterize the heat transfer from the source and from the interior fluid to the enclosure walls, respectively. It is found that the heat transfer from the source to the fluid can be maximized if the source is placed in the main stream from the inlet to the outlet port. In this case, the Reynolds number and heat source position have the major impact on the heat transfer. A disadvantageous position has been found where natural and forced convection compete each other. The overall heat transfer from the source to the wall increases with increasing Reynolds number as well as with increasing aspect ratio and decreasing inclination angle. The heat transfer from the interior fluid to the enclosure wall increases upon decreasing the aspect ratio and increasing the inclination angle. This counteracting behaviour is caused by the variation of the area of the enclosure wall. All mixed convection results are compared to the natural convection limit.
Abstract: In two studies we tested the hypothesis that the
appropriate linguistic formulation of a deontic rule – i.e. the
formulation which clarifies the monadic nature of deontic operators
- should produce more correct responses than the conditional
formulation in Wason selection task. We tested this assumption by
presenting a prescription rule and a prohibition rule in conditional
vs. proper deontic formulation. We contrasted this hypothesis with
two other hypotheses derived from social contract theory and
relevance theory. According to the first theory, a deontic rule
expressed in terms of cost-benefit should elicit a cheater detection
module, sensible to mental states attributions and thus able to
discriminate intentional rule violations from accidental rule
violations. We tested this prevision by distinguishing the two types
of violations. According to relevance theory, performance in
selection task should improve by increasing cognitive effect and
decreasing cognitive effort. We tested this prevision by focusing
experimental instructions on the rule vs. the action covered by the
rule. In study 1, in which 480 undergraduates participated, we
tested these predictions through a 2 x 2 x 2 x 2 (type of the rule x
rule formulation x type of violation x experimental instructions)
between-subjects design. In study 2 – carried out by means of a 2 x
2 (rule formulation x type of violation) between-subjects design -
we retested the hypothesis of rule formulation vs. the cheaterdetection
hypothesis through a new version of selection task in
which intentional vs. accidental rule violations were better
discriminated. 240 undergraduates participated in this study.
Results corroborate our hypothesis and challenge the contrasting
assumptions. However, they show that the conditional formulation
of deontic rules produces a lower performance than what is
reported in literature.
Abstract: A conjugate heat transfer for steady two-dimensional
mixed convection with magnetic hydrodynamic (MHD) flow of an
incompressible quiescent fluid over an unsteady thermal forming
stretching sheet has been studied. A parameter, M, which is used to
represent the dominance of the magnetic effect has been presented in
governing equations. The similar transformation and an implicit
finite-difference method have been used to analyze the present
problem. The numerical solutions of the flow velocity distributions,
temperature profiles, the wall unknown values of f''(0) and '(θ (0) for
calculating the heat transfer of the similar boundary-layer flow are
carried out as functions of the unsteadiness parameter (S), the Prandtl
number (Pr), the space-dependent parameter (A) and
temperature-dependent parameter (B) for heat source/sink and the
magnetic parameter (M). The effects of these parameters have also
discussed. At the results, it will produce greater heat transfer effect
with a larger Pr and M, S, A, B will reduce heat transfer effects. At
last, conjugate heat transfer for the free convection with a larger G has
a good heat transfer effect better than a smaller G=0.
Abstract: A numerical study has been carried out to investigate
the heat transfer by natural convection of nanofluid taking Cu as
nanoparticles and the water as based fluid in a three dimensional
annulus enclosure filled with porous media (silica sand) between two
horizontal concentric cylinders with 12 annular fins of 2.4mm
thickness attached to the inner cylinder under steady state conditions.
The governing equations which used are continuity, momentum and
energy equations under an assumptions used Darcy law and
Boussinesq-s approximation which are transformed to dimensionless
equations. The finite difference approach is used to obtain all the
computational results using the MATLAB-7. The parameters affected
on the system are modified Rayleigh number (10 ≤Ra*≤ 1000), fin
length Hf (3, 7 and 11mm), radius ratio Rr (0.293, 0.365 and 0.435)
and the volume fraction(0 ≤ ¤ò ≤ 0 .35). It was found that the
average Nusselt number depends on (Ra*, Hf, Rr and φ). The results
show that, increasing of fin length decreases the heat transfer rate and
for low values of Ra*, decreasing Rr cause to decrease Nu while for
Ra*
greater than 100, decreasing Rr cause to increase Nu and adding
Cu nanoparticles with 0.35 volume fraction cause 27.9%
enhancement in heat transfer. A correlation for Nu in terms of Ra*,
Hf and φ, has been developed for inner hot cylinder.
Abstract: The present work demonstrates the design and simulation of a fuzzy control of an air conditioning system at different pressures. The first order Sugeno fuzzy inference system is utilized to model the system and create the controller. In addition, an estimation of the heat transfer rate and water mass flow rate injection into or withdraw from the air conditioning system is determined by the fuzzy IF-THEN rules. The approach starts by generating the input/output data. Then, the subtractive clustering algorithm along with least square estimation (LSE) generates the fuzzy rules that describe the relationship between input/output data. The fuzzy rules are tuned by Adaptive Neuro-Fuzzy Inference System (ANFIS). The results show that when the pressure increases the amount of water flow rate and heat transfer rate decrease within the lower ranges of inlet dry bulb temperatures. On the other hand, and as pressure increases the amount of water flow rate and heat transfer rate increases within the higher ranges of inlet dry bulb temperatures. The inflection in the pressure effect trend occurs at lower temperatures as the inlet air humidity increases.
Abstract: In the present study, the pressure drop and laminar convection heat transfer characteristics of nanofluids in microchannel heat sink with square duct are numerically investigated. The water based nanofluids created with Al2O3 and CuO particles in four different volume fractions of 0%, 0.5%, 1%, 1.5% and 2% are used to analyze their effects on heat transfer and the pressure drop. Under the laminar, steady-state flow conditions, the finite volume method is used to solve the governing equations of heat transfer. Mixture Model is considered to simulate the nanofluid flow. For verification of used numerical method, the results obtained from numerical calculations were compared with the results in literature for both pure water and the nanofluids in different volume fractions. The distributions of the particles in base fluid are assumed to be uniform. The results are evaluated in terms of Nusselt number, the pressure drop and heat transfer enhancement. Analysis shows that the nanofluids enhance heat transfer while the Reynolds number and the volume fractions are increasing. The best overall enhancement was obtained at φ=%2 and Re=100 for CuO-water nanofluid.
Abstract: We report the results of an lattice Boltzmann
simulation of magnetohydrodynamic damping of sidewall convection
in a rectangular enclosure filled with a porous medium. In particular
we investigate the suppression of convection when a steady magnetic
field is applied in the vertical direction. The left and right vertical
walls of the cavity are kept at constant but different temperatures
while both the top and bottom horizontal walls are insulated. The
effects of the controlling parameters involved in the heat transfer and
hydrodynamic characteristics are studied in detail. The heat and mass
transfer mechanisms and the flow characteristics inside the enclosure
depended strongly on the strength of the magnetic field and Darcy
number. The average Nusselt number decreases with rising values of
the Hartmann number while this increases with increasing values of
the Darcy number.
Abstract: Computational fluid dynamics (CFD) simulations
carried out in this paper show that spacer orientation has a major
influence on temperature patterns and on the heat transfer rates. The
local heat flux values significantly vary from high to very low values
at each filament when spacer touches the membrane surface. The
heat flux profile is more uniform when spacer filaments are not in
contact with the membrane thus making this arrangement more
beneficial. The temperature polarization is also found to be less in
this case when compared to the empty channel.
Abstract: In this paper, we present a framework to determine Haar solutions of Bratu-type equations that are widely applicable in fuel ignition of the combustion theory and heat transfer. The method is proposed by applying Haar series for the highest derivatives and integrate the series. Several examples are given to confirm the efficiency and the accuracy of the proposed algorithm. The results show that the proposed way is quite reasonable when compared to exact solution.