Abstract: Aluminum alloy sheets have several advantages such
as the lightweight, high-specific strength and recycling efficiency.
Therefore, aluminum alloy sheets in sheet forming have been used in various areas as automotive components and so forth. During the
process of sheet forming, wrinkling which is caused by compression stress might occur and the formability of sheets was affected by
occurrence of wrinkling. A few studies of uniaxial compressive test by
using square tubes, pipes and sheets were carried out to clarify the each wrinkling behavior. However, on uniaxial compressive test,
deformation behavior of the sheets hasn-t be cleared. Then, it is necessary to clarify the relationship between the buckling behavior
and the forming conditions. In this study, the effect of dimension of the sheet in the buckling behavior on compression test of aluminum alloy sheet was cleared by experiment and FEA. As the results, the buckling
deformation was classified by three modes in terms of the distribution of equivalent plastic strain.
Abstract: In this paper, a method based on Non-Dominated
Sorting Genetic Algorithm (NSGA) has been presented for the Volt /
Var control in power distribution systems with dispersed generation
(DG). Genetic algorithm approach is used due to its broad
applicability, ease of use and high accuracy. The proposed method is
better suited for volt/var control problems. A multi-objective
optimization problem has been formulated for the volt/var control of
the distribution system. The non-dominated sorting genetic algorithm
based method proposed in this paper, alleviates the problem of tuning
the weighting factors required in solving the multi-objective volt/var
control optimization problems. Based on the simulation studies
carried out on the distribution system, the proposed scheme has been
found to be simple, accurate and easy to apply to solve the multiobjective
volt/var control optimization problem of the distribution
system with dispersed generation.
Abstract: This study is aimed to investigate feasibility of the
aerobic biological process to treat oily wastewater from palm oil food
industry. Effect of aeration and sludge concentrations are studied.
Raw sludge and raw wastewater was mixed and acclimatized for five
days in a stirred tank reactor. The aeration rate (no aeration, low;
1.5L/min and high rate; 2L/min) and sludge concentration (3675,
7350, and 11025mg/L of VSS) were varied. Responses of process
were pH, COD, oil and grease, VSS, and PHB content. It was found
that the treatment can remove 85.1 to 97.1 % of COD and remove
12.9 to 54.8% of oil & grease. The PHB yield was found to be within
0.15% to 2.4% as PHB/VSS ratio and 0.01% to 0.12% as PHB/COD
removed. The higher aeration results a high COD removal and oil &
grease removal, while experiment without aeration gives better PHB
yield. Higher sludge concentrations (11025mg/L VSS) give higher
removal of oil & grease while moderate sludge concentration
(7350mg/L VSS) give better result in COD removal. Higher PHB
yield is obtained in low sludge concentration (3675mg/L).
Abstract: Even it has been recognized that Shape Memory
Alloys (SMA) have a significant potential for deployment actuators,
the number of applications of SMA-based actuators to the present
day is still quite small, due to the need of deep understanding of the
thermo-mechanical behavior of SMA, causing an important need for
a mathematical model able to describe all thermo-mechanical
properties of SMA by relatively simple final set of constitutive
equations. SMAs offer attractive potentials such as: reversible strains
of several percent, generation of high recovery stresses and high
power / weight ratios. The paper tries to provide an overview of the
shape memory functions and a presentation of the designed and
developed temperature control system used for a gripper actuated by
two pairs of differential SMA active springs. An experimental setup
was established, using electrical energy for actuator-s springs heating
process. As for holding the temperature of the SMA springs at certain
level for a long time was developed a control system in order to
avoid the active elements overheating.
Abstract: In this investigation, anatase TiO2 thin films were
grown by radio frequency magnetron sputtering on glass substrates at
a high sputtering pressure and room temperature. The anatase films
were then annealed at 300-600 °C in air for a period of 1 hour. To
examine the structure and morphology of the films, X-ray diffraction
(XRD) and atomic force microscopy (AFM) methods were used
respectively. From X-ray diffraction patterns of the TiO2 films, it was
found that the as-deposited film showed some differences compared
with the annealed films and the intensities of the peaks of the
crystalline phase increased with the increase of annealing
temperature. From AFM images, the distinct variations in the
morphology of the thin films were also observed. The optical
constants were characterized using the transmission spectra of the
films obtained by UV-VIS-IR spectrophotometer. Besides, optical
thickness of the film deposited at room temperature was calculated
and cross-checked by taking a cross-sectional image through SEM.
The optical band gaps were evaluated through Tauc model. It was
observed that TiO2 films produced at room temperatures exhibited
high visible transmittance and transmittance decreased slightly with
the increase of annealing temperatures. The films were found to be
crystalline having anatase phase. The refractive index of the films
was found from 2.31-2.35 in the visible range. The extinction
coefficient was nearly zero in the visible range and was found to
increase with annealing temperature. The allowed indirect optical
band gap of the films was estimated to be in the range from 3.39 to
3.42 eV which showed a small variation. The allowed direct band
gap was found to increase from 3.67 to 3.72 eV. The porosity was
also found to decrease at a higher annealing temperature making the
film compact and dense.
Abstract: In recent years, copulas have become very popular in
financial research and actuarial science as they are more flexible in
modelling the co-movements and relationships of risk factors as compared
to the conventional linear correlation coefficient by Pearson.
However, a precise estimation of the copula parameters is vital in
order to correctly capture the (possibly nonlinear) dependence structure
and joint tail events. In this study, we employ two optimization
heuristics, namely Differential Evolution and Threshold Accepting to
tackle the parameter estimation of multivariate t distribution models
in the EML approach. Since the evolutionary optimizer does not rely
on gradient search, the EML approach can be applied to estimation of
more complicated copula models such as high-dimensional copulas.
Our experimental study shows that the proposed method provides
more robust and more accurate estimates as compared to the IFM
approach.
Abstract: Because of the global warming and the rising sea level, residents living in southwestern coastland, Taiwan are faced with the submerged land and may move to higher elevation area. It is desirable to discuss the key consideration factor for selecting the migration location under five dimensions of ಯ security”, “health”, “convenience”, “comfort” and “socio-economic” based on the document reviews. This paper uses the Structural Equation Modeling (SEM) and the questionnaire survey. The analysis results show that the convenience is the most key factor for residents in Taiwan.
Abstract: This study experimentally and numerically investigates
motor cooling performance. The motor consists of a centrifugal fan,
two axial fans, a shaft, a stator, a rotor and a heat exchanger with 637
cooling tubes. The pressure rise-flow rate (P-Q) performance curves of
the cooling fans at 1800 rpm are tested using a test apparatus
complying with the Chinese National Standard (CNS) 2726.
Compared with the experimental measurements, the numerical
analysis results show that the P-Q performance curves of the axial fan
and centrifugal fan can be estimated within about 2% and 6%,
respectively. By using the simplified model, setting up the heat
exchanger and stator as porous media, the flow field in the motor is
calculated. By using the results of the flow field near the rotor and
stator, and subjecting the heat generation rate as a boundary condition,
the temperature distributions of the stator and rotor are also calculated.
The simulation results show that the calculated temperature of the
stator winding near the axial fans is lower by about 5% than the
measured value, and the calculated temperature of the stator core
located at the center of the stator is about 1% higher than the measured
value. Besides, discussion is made to improve the motor cooling
performance.
Abstract: Using 1km grid datasets representing monthly mean
precipitation, monthly mean temperature, and dry matter production
(DMP), we considered the regional plant production ability in
Southeast and South Asia, and also employed pixel-by-pixel
correlation analysis to assess the intensity of relation between climate
factors and plant production. While annual DMP in South Asia was
approximately less than 2,000kg, the one in most part of Southeast
Asia exceeded 2,500 - 3,000kg. It suggested that plant production in
Southeast Asia was superior to South Asia, however, Rain-Use
Efficiency (RUE) representing dry matter production per 1mm
precipitation showed that inland of Indochina Peninsula and India
were higher than islands in Southeast Asia. By the results of
correlation analysis between climate factors and DMP, while the area
in most parts of Indochina Peninsula indicated negative correlation
coefficients between DMP and precipitation or temperature, the area
in Malay Peninsula and islands showed negative correlation to
precipitation and positive one to temperature, and most part of India
dominating South Asia showed positive to precipitation and negative
to temperature. In addition, the areas where the correlation coefficients
exceeded |0.8| were regarded as “susceptible" to climate factors, and
the areas smaller than |0.2| were “insusceptible". By following the
discrimination, the map implying expected impacts by climate change
was provided.
Abstract: In this study the mixed mode fracture mechanics
parameters were investigated for high tensile steel butt welded joint
based on modified Arcan test and finite element analysis was used to
evaluate the effect of crack length on fracture criterion. The nondimensional
stress intensity factors, strain energy release rates and Jintegral
energy on crack tip were obtained for various in-plane
loading combinations on Arcan specimen starting from pure mode-I
to pure mode-II loading conditions. The specimen and apparatus were
modeled by finite element method and analyzed under various
loading angles (between 0 to 90 degrees with 15 degree interval) to
simulate the pure mode-I, II and mixed mode fracture. Since the
analytical results are independent from elasticity modules for
isotropic materials, therefore the results in elastic fields can be used
for Arcan specimens. The main objective of this study was to
evaluate the geometric calibration factors for modified Arcan test
specimen in order to obtain fracture toughness under mixed mode
loading conditions.
Abstract: Hazardous Material transportation by road is coupled
with inherent risk of accidents causing loss of lives, grievous injuries,
property losses and environmental damages. The most common type
of hazmat road accident happens to be the releases (78%) of
hazardous substances, followed by fires (28%), explosions (14%) and
vapour/ gas clouds (6 %.).
The paper is discussing initially the probable 'Impact Zones'
likely to be caused by one flammable (LPG) and one toxic (ethylene
oxide) chemicals being transported through a sizable segment of a
State Highway connecting three notified Industrial zones in Surat
district in Western India housing 26 MAH industrial units. Three
'hotspots' were identified along the highway segment depending on
the particular chemical traffic and the population distribution within
500 meters on either sides. The thermal radiation and explosion
overpressure have been calculated for LPG / Ethylene Oxide BLEVE
scenarios along with toxic release scenario for ethylene oxide.
Besides, the dispersion calculations for ethylene oxide toxic release
have been made for each 'hotspot' location and the impact zones
have been mapped for the LOC concentrations. Subsequently, the
maximum Initial Isolation and the protective zones were calculated
based on ERPG-3 and ERPG-2 values of ethylene oxide respectively
which are estimated taking the worst case scenario under worst
weather conditions. The data analysis will be helpful to the local
administration in capacity building with respect to rescue /
evacuation and medical preparedness and quantitative inputs to
augment the District Offsite Emergency Plan document.
Abstract: The demand on High voltage (HV) infrastructures is growing due to the corresponding growth in industries and population. Many areas are being developed and therefore require additional electrical power to comply with the demand. Substation upgrade is one of the rapid solutions to ensure the continuous supply of power to customers. This upgrade requires civil modifications to structures and fences. The civil work requires excavation and steel works that may create unsafe touch conditions. This paper presents a brief theoretical overview of the touch voltage inside and around substations and uses CDEGS software to simulate a case study.
Abstract: This paper presents ageing experiments controlled by the evolution of junction parameters. The deterioration of the device is related to high injection effects which modified the transport mechanisms in the space charge region of the junction. Physical phenomena linked to the degradation of junction parameters that affect the devices reliability are reported and discussed. We have used the method based on numerical analysis of experimental current-voltage characteristic of the junction, in order to extract the electrical parameters. The simultaneous follow-up of the evolutions of the series resistance and of the transition voltage allow us to introduce a new parameter for reliability evaluation.
Abstract: We proposed a technique to identify road traffic
congestion levels from velocity of mobile sensors with high accuracy
and consistent with motorists- judgments. The data collection utilized
a GPS device, a webcam, and an opinion survey. Human perceptions
were used to rate the traffic congestion levels into three levels: light,
heavy, and jam. Then the ratings and velocity were fed into a
decision tree learning model (J48). We successfully extracted vehicle
movement patterns to feed into the learning model using a sliding
windows technique. The parameters capturing the vehicle moving
patterns and the windows size were heuristically optimized. The
model achieved accuracy as high as 99.68%. By implementing the
model on the existing traffic report systems, the reports will cover
comprehensive areas. The proposed method can be applied to any
parts of the world.
Abstract: The use of amine mixtures employing
methyldiethanolamine (MDEA), monoethanolamine (MEA), and diethanolamine (DEA) have been investigated for a variety of cases
using a process simulation program called HYSYS. The results show that, at high pressures, amine mixtures have little or no advantage in the cases studied. As the pressure is lowered, it becomes more difficult for MDEA to meet residual gas requirements and mixtures can usually improve plant performance. Since the CO2 reaction rate
with the primary and secondary amines is much faster than with
MDEA, the addition of small amounts of primary or secondary amines to an MDEA based solution should greatly improve the overall reaction rate of CO2 with the amine solution. The addition of MEA caused the CO2 to be absorbed more strongly in the upper portion of the column than for MDEA along. On the other hand,
raising the concentration for MEA to 11%wt, CO2 is almost
completely absorbed in the lower portion of the column. The addition of MEA would be most advantageous.
Thus, in areas where MDEA cannot meet the residual gas
requirements, the use of amine mixtures can usually improve the plant
performance.
Abstract: The structure of retinal vessels is a prominent feature,
that reveals information on the state of disease that are reflected in
the form of measurable abnormalities in thickness and colour.
Vascular structures of retina, for implementation of clinical diabetic
retinopathy decision making system is presented in this paper.
Retinal Vascular structure is with thin blood vessel, whose accuracy
is highly dependent upon the vessel segmentation. In this paper the
blood vessel thickness is automatically detected using preprocessing
techniques and vessel segmentation algorithm. First the capture
image is binarized to get the blood vessel structure clearly, then it is
skeletonised to get the overall structure of all the terminal and
branching nodes of the blood vessels. By identifying the terminal
node and the branching points automatically, the main and branching
blood vessel thickness is estimated. Results are presented and
compared with those provided by clinical classification on 50 vessels
collected from Bejan Singh Eye hospital..
Abstract: In this paper we investigate the electrical
characteristics of a new structure of gate all around strained silicon
nanowire field effect transistors (FETs) with dual dielectrics by
changing the radius (RSiGe) of silicon-germanium (SiGe) wire and
gate dielectric. Indeed the effect of high-κ dielectric on Field Induced
Barrier Lowering (FIBL) has been studied. Due to the higher electron
mobility in tensile strained silicon, the n-type FETs with strained
silicon channel have better drain current compare with the pure Si
one. In this structure gate dielectric divided in two parts, we have
used high-κ dielectric near the source and low-κ dielectric near the
drain to reduce the short channel effects. By this structure short
channel effects such as FIBL will be reduced indeed by increasing
the RSiGe, ID-VD characteristics will be improved. The leakage
current and transfer characteristics, the threshold-voltage (Vt), the
drain induced barrier height lowering (DIBL), are estimated with
respect to, gate bias (VG), RSiGe and different gate dielectrics. For
short channel effects, such as DIBL, gate all around strained silicon
nanowire FET have similar characteristics with the pure Si one while
dual dielectrics can improve short channel effects in this structure.
Abstract: Background: Widespread use of chemotherapeutic
drugs in the treatment of cancer has lead to higher health hazards
among employee who handle and administer such drugs, so nurses
should know how to protect themselves, their patients and their work
environment against toxic effects of chemotherapy. Aim of this study
was carried out to examine the effect of chemotherapy safety protocol
for oncology nurses on their protective measure practices. Design: A
quasi experimental research design was utilized. Setting: The study
was carried out in oncology department of Menoufia university
hospital and Tanta oncology treatment center. Sample: A
convenience sample of forty five nurses in Tanta oncology treatment
center and eighteen nurses in Menoufiya oncology department.
Tools: 1. an interviewing questionnaire that covering sociodemographic
data, assessment of unit and nurses' knowledge about
chemotherapy. II: Obeservational check list to assess nurses' actual
practices of handling and adminestration of chemotherapy. A base
line data were assessed before implementing Chemotherapy Safety
protocol, then Chemotherapy Safety protocol was implemented, and
after 2 monthes they were assessed again. Results: reveled that 88.9%
of study group I and 55.6% of study group II improved to good total
knowledge scores after educating on the safety protocol, also 95.6%
of study group I and 88.9% of study group II had good total practice
score after educating on the safety protocol. Moreover less than half
of group I (44.4%) reported that heavy workload is the most barriers
for them, while the majority of group II (94.4%) had many barriers
for adhering to the safety protocol such as they didn’t know the
protocol, the heavy work load and inadequate equipment.
Conclusions: Safety protocol for Oncology Nurses seemed to have
positive effect on improving nurses' knowledge and practice.
Recommendation: chemotherapy safety protocol should be instituted
for all oncology nurses who are working in any oncology unit and/ or
center to enhance compliance, and this protocol should be done at
frequent intervals.
Abstract: Clean air in subway station is important to passengers. The Platform Screen Doors (PSDs) can improve indoor air quality in the subway station; however the air quality in the subway tunnel is degraded. The subway tunnel has high CO2 concentration and indoor particulate matter (PM) value. The Indoor Air Quality (IAQ) level in subway environment degrades by increasing the frequency of the train operation and the number of the train. The ventilation systems of the subway tunnel need improvements to have better air-quality. Numerical analyses might be effective tools to analyze the performance of subway twin-track tunnel ventilation systems. An existing subway twin-track tunnel in the metropolitan Seoul subway system is chosen for the numerical simulations. The ANSYS CFX software is used for unsteady computations of the airflow inside the twin-track tunnel when the train moves. The airflow inside the tunnel is simulated when one train runs and two trains run at the same time in the tunnel. The piston-effect inside the tunnel is analyzed when all shafts function as the natural ventilation shaft. The supplied air through the shafts is mixed with the pollutant air in the tunnel. The pollutant air is exhausted by the mechanical ventilation shafts. The supplied and discharged airs are balanced when only one train runs in the twin-track tunnel. The pollutant air in the tunnel is high when two trains run simultaneously in opposite direction and all shafts functioned as the natural shaft cases when there are no electrical power supplies in the shafts. The remained pollutant air inside the tunnel enters into the station platform when the doors are opened.
Abstract: Overcurrent (OC) relays are the major protection
devices in a distribution system. The operating time of the OC relays
are to be coordinated properly to avoid the mal-operation of the
backup relays. The OC relay time coordination in ring fed
distribution networks is a highly constrained optimization problem
which can be stated as a linear programming problem (LPP). The
purpose is to find an optimum relay setting to minimize the time of
operation of relays and at the same time, to keep the relays properly
coordinated to avoid the mal-operation of relays.
This paper presents two phase simplex method for optimum time
coordination of OC relays. The method is based on the simplex
algorithm which is used to find optimum solution of LPP. The
method introduces artificial variables to get an initial basic feasible
solution (IBFS). Artificial variables are removed using iterative
process of first phase which minimizes the auxiliary objective
function. The second phase minimizes the original objective function
and gives the optimum time coordination of OC relays.