Abstract: This paper presents a methodology to assess the voltage stability status combined with optimal power flow technique using an instantaneous two-bus equivalent model of power system incorporating static var compensator (SVC) and thyristor controlled series compensator (TCSC) controllers. There by, a generalized global voltage stability indicator being developed has been applied to a robust practical Indian Eastern Grid 203-bus system. Simulation results have proved that the proposed methodology is promising to assess voltage stability of any power system at any operating point in global scenario. Voltage stability augmentation with the application of SVC at the weakest bus and TCSC at critical line connected to the weakest bus is compared with the system having no compensation. In the proposed network equivalent model the generators have been modeled more accurately considering economic criteria.
Abstract: According to the increasing utilization in power system, the transmission lines and power plants often operate in stability boundary and system probably lose its stable condition by over loading or occurring disturbance. According to the reasons that are mentioned, the prediction and recognition of voltage instability in power system has particular importance and it makes the network security stronger.This paper, by considering of power system contingencies based on the effects of them on Mega Watt Margin (MWM) and maximum loading point is focused in order to analyse the static voltage stability using continuation power flow method. The study has been carried out on IEEE 14-Bus Test System using Matlab and Psat softwares and results are presented.
Abstract: At present, it is very common to find renewable
energy resources, especially wind power, connected to distribution
systems. The impact of this wind power on voltage distribution levels
has been addressed in the literature. The majority of this works deals
with the determination of the maximum active and reactive power
that is possible to be connected on a system load bus, until the
voltage at that bus reaches the voltage collapse point. It is done by the
traditional methods of PV curves reported in many references.
Theoretical expression of maximum power limited by voltage
stability transfer through a grid is formulated using an exact
representation of distribution line with ABCD parameters. The
expression is used to plot PV curves at various power factors of a
radial system. Limited values of reactive power can be obtained. This
paper presents a method to study the relationship between the active
power and voltage (PV) at the load bus to identify the voltage
stability limit. It is a foundation to build a permitted working
operation region in complying with the voltage stability limit at the
point of common coupling (PCC) connected wind farm.
Abstract: One of the major causes of voltage instability is the reactive power limit of the system. Improving the system's reactive power handling capacity via Flexible AC transmission System (FACTS) devices is a remedy for prevention of voltage instability and hence voltage collapse. In this paper, the effects of SVC and STATCOM in Static Voltage Stability Margin Enhancement will be studied. AC and DC representations of SVC and STATCOM are used in the continuation power flow process in static voltage stability study. The IEEE-14 bus system is simulated to test the increasing loadability. It is found that these controllers significantly increase the loadability margin of power systems.
Abstract: Voltage stability has become an important issue to many power systems around the world due to the weak systems and long line on power system networks. In this paper, MATLAB load flow program is applied to obtain the weak points in the system combined with finding the voltage stability limit. The maximum permissible loading of a system, within the voltage stability limit, is usually determined. The methods for varying tap ratio (using tap changing transformer) and applying different values of shunt capacitor injection to improve the voltage stability within the limit are also provided.
Abstract: In this paper, we propose an easily computable proximity index for predicting voltage collapse of a load bus using only measured values of the bus voltage and power; Using these measurements a polynomial of fourth order is obtained by using LES estimation algorithms. The sum of the absolute values of the polynomial coefficient gives an idea of the critical bus. We demonstrate the applicability of our proposed method on 6 bus test system. The results obtained verify its applicability, as well as its accuracy and the simplicity. From this indicator, it is allowed to predict the voltage instability or the proximity of a collapse. Results obtained by the PV curve are compared with corresponding values by QV curves and are observed to be in close agreement.
Abstract: Electricity market activities and a growing demand for electricity have led to heavily stressed power systems. This requires operation of the networks closer to their stability limits. Power system operation is affected by stability related problems, leading to unpredictable system behavior. Voltage stability refers to the ability of a power system to sustain appropriate voltage levels through large and small disturbances. Steady-state voltage stability is concerned with limits on the existence of steady-state operating points for the network. FACTS devices can be utilized to increase the transmission capacity, the stability margin and dynamic behavior or serve to ensure improved power quality. Their main capabilities are reactive power compensation, voltage control and power flow control. Among the FACTS controllers, Static Var Compensator (SVC) provides fast acting dynamic reactive compensation for voltage support during contingency events. In this paper, voltage stability assessment with appropriate representations of tap-changer transformers and SVC is investigated. Integrating both of these devices is the main topic of this paper. Effect of the presence of tap-changing transformers on static VAR compensator controller parameters and ratings necessary to stabilize load voltages at certain values are highlighted. The interrelation between transformer off nominal tap ratios and the SVC controller gains and droop slopes and the SVC rating are found. P-V curves are constructed to calculate loadability margins.
Abstract: Many real-world optimization problems involve multiple conflicting objectives and the use of evolutionary algorithms to solve the problems has attracted much attention recently. This paper investigates the application of multi-objective optimization technique for the design of a Thyristor Controlled Series Compensator (TCSC)-based controller to enhance the performance of a power system. The design objective is to improve both rotor angle stability and system voltage profile. A Genetic Algorithm (GA) based solution technique is applied to generate a Pareto set of global optimal solutions to the given multi-objective optimisation problem. Further, a fuzzy-based membership value assignment method is employed to choose the best compromise solution from the obtained Pareto solution set. Simulation results are presented to show the effectiveness and robustness of the proposed approach.
Abstract: Based on the component approach, three kinds of
dynamic load models, including a single –motor model, a two-motor
model and composite load model have been developed for the
stability studies of Khuzestan power system. The study results are
presented in this paper. Voltage instability is a dynamic phenomenon
and therefore requires dynamic representation of the power system
components. Industrial loads contain a large fraction of induction
machines. Several models of different complexity are available for
the description investigations. This study evaluates the dynamic
performances of several dynamic load models in combination with
the dynamics of a load changing transformer. Case study is steel
industrial substation in Khuzestan power systems.
Abstract: The steady-state operation of maintaining voltage
stability is done by switching various controllers scattered all over
the power network. When a contingency occurs, whether forced or
unforced, the dispatcher is to alleviate the problem in a minimum
time, cost, and effort. Persistent problem may lead to blackout. The
dispatcher is to have the appropriate switching of controllers in terms
of type, location, and size to remove the contingency and maintain
voltage stability. Wrong switching may worsen the problem and that
may lead to blackout. This work proposed and used a Fuzzy CMeans
Clustering (FCMC) to assist the dispatcher in the decision
making. The FCMC is used in the static voltage stability to map
instantaneously a contingency to a set of controllers where the types,
locations, and amount of switching are induced.
Abstract: Voltage collapse is instability of heavily loaded electric
power systems that cause to declining voltages and blackout. Power
systems are predicated to become more heavily loaded in the future
decade as the demand for electric power rises while economic and
environmental concerns limit the construction of new transmission
and generation capacity. Heavily loaded power systems are closer to
their stability limits and voltage collapse blackouts will occur if
suitable monitoring and control measures are not taken. To control
transmission lines, it can be used from FACTS devices.
In this paper Harmony search algorithm (HSA) and Genetic
Algorithm (GA) have applied to determine optimal location of
FACTS devices in a power system to improve power system stability.
Three types of FACTS devices (TCPAT, UPFS, and SVC) have been
introduced. Bus under voltage has been solved by controlling reactive
power of shunt compensator. Also a combined series-shunt
compensators has been also used to control transmission power flow
and bus voltage simultaneously.
Different scenarios have been considered. First TCPAT, UPFS, and
SVC are placed solely in transmission lines and indices have been
calculated. Then two types of above controller try to improve
parameters randomly. The last scenario tries to make better voltage
stability index and losses by implementation of three types controller
simultaneously. These scenarios are executed on typical 34-bus test
system and yields efficiency in improvement of voltage profile and
reduction of power losses; it also may permit an increase in power
transfer capacity, maximum loading, and voltage stability margin.
Abstract: At any point of time, a power system operating
condition should be stable, meeting various operational criteria and it
should also be secure in the event of any credible contingency. Present
day power systems are being operated closer to their stability limits
due to economic and environmental constraints. Maintaining a stable
and secure operation of a power system is therefore a very important
and challenging issue. Voltage instability has been given much
attention by power system researchers and planners in recent years,
and is being regarded as one of the major sources of power system
insecurity. Voltage instability phenomena are the ones in which the
receiving end voltage decreases well below its normal value and does
not come back even after setting restoring mechanisms such as VAR
compensators, or continues to oscillate for lack of damping against the
disturbances. Reactive power limit of power system is one of the major
causes of voltage instability. This paper investigates the effects of
coordinated series capacitors (SC) with static VAR compensators
(SVC) on steady-state voltage stability of a power system. Also, the
influence of the presence of series capacitor on static VAR
compensator controller parameters and ratings required to stabilize
load voltages at certain values are highlighted.
Abstract: Analytical expression for maximum power transfer
through a transmission line limited by voltage stability has been
formulated using exact representation of transmission line with
ABCD parameters. The expression has been used for plotting PV
curve at different power factors of a radial transmission line.
Limiting values of reactive power have been obtained.
Abstract: This paper proposes a methodology for mitigating the occurrence of cascading failure in stressed power systems. The methodology is essentially based on predicting voltage instability in the power system using a voltage stability index and then devising a corrective action in order to increase the voltage stability margin. The paper starts with a brief description of the cascading failure mechanism which is probable root cause of severe blackouts. Then, the voltage instability indices are introduced in order to evaluate stability limit. The aim of the analysis is to assure that the coordination of protection, by adopting load shedding scheme, capable of enhancing performance of the system after the major location of instability is determined. Finally, the proposed method to generate instability prediction is introduced.
Abstract: Estimation of voltage stability based on optimal
filtering method is presented. PV curve is used as a tool for voltage stability analysis. Dynamic voltage stability estimation is done by
using particle filter method. Optimum value (nose point) of PV curve can be estimated by estimating parameter of PV curve equation
optimal value represents critical voltage and
condition at specified point of measurement. Voltage stability is then estimated by analyzing loading margin condition c stimating equation. This
maximum loading
ecified dynamically.
Abstract: Particle Swarm Optimization (PSO) with elite PSO
parameters has been developed for power flow analysis under
practical constrained situations. Multiple solutions of the power flow
problem are useful in voltage stability assessment of power system.
A method of determination of multiple power flow solutions is
presented using a hybrid of Particle Swarm Optimization (PSO) and
local search technique. The unique and innovative learning factors of
the PSO algorithm are formulated depending upon the node power
mismatch values to be highly adaptive with the power flow problems.
The local search is applied on the pbest solution obtained by the PSO
algorithm in each iteration. The proposed algorithm performs reliably
and provides multiple solutions when applied on standard and illconditioned
systems. The test results show that the performances of
the proposed algorithm under critical conditions are better than the
conventional methods.