Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: This paper presents the experimental results of silicone rubber housing material for 24kV lightning arrester under artificial accelerated ageing test based on IEC 61109 specifications. Specimens having inclined and alternated shed made of HTV silicone rubber with ATH content and having leakage distance 625 mm were tested continuously 1000 hrs in artificial salt fog chamber. After 1000 hrs of salt fog ageing test, obviously surface erosion was observed on trunk between the upper large shed and the lower small shed near the energized end. Decreasing in hydrophobicity and increasing in hardness were measured on tested specimen comparing with new specimen. Chemical analysis by ATR-FTIR confirmed the observation results.
Abstract: The rapid adoption of Internet has turned the Millennial Teens- life like a lightning speed. Empirical evidence has illustrated that Pathological Internet Use (PIU) among them ensure long-term success to the market players in the children industry. However, it creates concerns among their care takers as it generates mental disorder among some of them. The purpose of this paper is to examine the determinants of PIU and identify its outcomes among urban Millennial Teens. It aims to develop a theoretical framework based on a modified Media System Dependency (MSD) Theory that integrates important systems and components that determine and resulted from PIU.
Abstract: Power transformer consists of components which are
under consistent thermal and electrical stresses. The major
component which degrades under these stresses is the paper
insulation of the power transformer. At site, lightning impulses and
cable faults may cause the winding deformation. In addition, the
winding may deform due to impact during transportation. A
deformed winding will excite more stress to its insulating paper thus
will degrade it. Insulation degradation will shorten the life-span of
the transformer. Currently there are two methods of detecting the
winding deformation which are Sweep Frequency Response
Analysis (SFRA) and Low Voltage Impulse Test (LVI). The latter
injects current pulses to the winding and capture the admittance
plot. In this paper, a transformer which experienced overheating and
arcing was identified, and both SFRA and LVI were performed.
Next, the transformer was brought to the factory for untanking. The
untanking results revealed that the LVI is more accurate than the
SFRA method for this case study.
Abstract: This paper describes a finite-difference time-domainFDTD) method to analyze lightning surge propagation in electric transmission lines. Numerical computation of solving the Telegraphist-s equations is determined and investigated its effectiveness. A source of lightning surge wave on power transmission lines is modeled by using Heidler-s surge model. The
proposed method was tested against medium-voltage power
transmission lines in comparison with the solution obtained by using
lattice diagram. As a result, the calculation showed that the method is one of accurate methods to analyze transient
lightning wave in power transmission lines.
Abstract: This study describes analysis of tower grounding
resistance effected the back flashover voltage across insulator string
in a transmission system. This paper studies the 500 kV transmission
lines from Mae Moh, Lampang to Nong Chok, Bangkok, Thailand,
which is double circuit in the same steel tower with two overhead
ground wires. The factor of this study includes magnitude of
lightning stroke, and front time of lightning stroke. Steel tower uses
multistory tower model. The assumption of studies based on the
return stroke current ranged 1-200 kA, front time of lightning stroke
between 1 μs to 3 μs. The simulations study the effect of varying
tower grounding resistance that affect the lightning current.
Simulation results are analyzed lightning over voltage that causes
back flashover at insulator strings. This study helps to know causes
of problems of back flashover the transmission line system, and also
be as a guideline solving the problem for 500 kV transmission line
systems, as well.
Abstract: Monitoring lightning electromagnetic pulses (sferics) and other terrestrial as well as extraterrestrial transient radiation signals is of considerable interest for practical and theoretical purposes in astro- and geophysics as well as meteorology. Managing a continuous flow of data, automation of the analysis and classification process is important. Features based on a combination of wavelet and statistical methods proved efficient for this task and serve as input into a radial basis function network that is trained to discriminate transient shapes from pulse like to wave like. We concentrate on signals in the Very Low Frequency (VLF, 3 -30 kHz) range in this paper, but the developed methods are independent of this specific choice.
Abstract: The scope of this paper is to describe a real electrical
installation of renewable energy using photovoltaic cells. The
displayed power grid connected network was established in 2007 at
area of Northern Greece. The photovoltaic park is composed of 6120
photovoltaic cells able to deliver a total power of 1.101.600 Wp. For
the transformation of DC voltage to AC voltage have been used 25
stand alone three phases inverters and for the connection at the
medium voltage network of Greek Power Authority have been
installed two oil immersed transformer of 630 kVA each one. Due to
the wide space area of installation a specific external lightning
protection system has been designed. Additionally, due to the
sensitive electronics of the control and protection systems of park,
surge protection, equipotent bonding and shielding were also of
major importance.