Abstract: With the growth of electricity generation from gas
energy gas pipeline reliability can substantially impact the electric
generation. A physical disruption to pipeline or to a compressor
station can interrupt the flow of gas or reduce the pressure and lead
to loss of multiple gas-fired electric generators, which could
dramatically reduce the supplied power and threaten the power
system security. Gas pressure drops during peak loading time on
pipeline system, is a common problem in network with no enough
transportation capacity which limits gas transportation and causes
many problem for thermal domain power systems in supplying their
demand. For a feasible generation scheduling planning in networks
with no sufficient gas transportation capacity, it is required to
consider gas pipeline constraints in solving the optimization problem
and evaluate the impacts of gas consumption in power plants on gas
pipelines operating condition. This paper studies about operating of
gas fired power plants in critical conditions when the demand of gas
and electricity peak together. An integrated model of gas and electric
model is used to consider the gas pipeline constraints in the economic
dispatch problem of gas-fueled thermal generator units.
Abstract: This paper presents the experimental results of
discharge current phenomena on various humidity, temperature,
pressure and pollutant conditions of epoxy resin specimen. The
leakage distance of specimen was 3 cm, that it was supplied by high
voltage. The polluted condition was given with NaCl artificial
pollutant. The conducted measurements were discharge current and
applied voltage. The specimen was put in a hermetically sealed
chamber, and the current waveforms were analyzed with FFT.
The result indicated that on discharge condition, the fifth
harmonics still had dominant, rather than third one. The third
harmonics tent to be appeared on low pressure heavily polluted
condition, and followed by high humidity heavily polluted condition.
On the heavily polluted specimen, the peaks discharge current points
would be high and more frequent. Nevertheless, the specimen still
had capacitive property. Besides that, usually discharge current
points were more frequent. The influence of low pressure was still
dominant to be easier to discharge. The non-linear property would be
appear explicitly on low pressure and heavily polluted condition.
Abstract: This paper presents a developed method for
controlling multi-renewable energy generators. The control system
depends basically on three sensors (wind anemometer, solar sensor,
and voltage sensor). These sensors represent PLC-s analogue inputs.
Controlling the output voltage supply can be achieved by an
enhanced method of interlocking between the renewable energy
generators, depending on those sensors and output contactors.
Abstract: Biometrics methods include recognition techniques
such as fingerprint, iris, hand geometry, voice, face, ears and gait. The gait recognition approach has some advantages, for example it
does not need the prior concern of the observed subject and it can
record many biometric features in order to make deeper analysis, but
most of the research proposals use high computational cost. This
paper shows a gait recognition system with feature subtraction on a
bundle rectangle drawn over the observed person. Statistical results
within a database of 500 videos are shown.
Abstract: Electromagnetic interference (EMI) is one of the
serious problems in most electrical and electronic appliances
including fluorescent lamps. The electronic ballast used to regulate
the power flow through the lamp is the major cause for EMI. The
interference is because of the high frequency switching operation of
the ballast. Formerly, some EMI mitigation techniques were in
practice, but they were not satisfactory because of the hardware
complexity in the circuit design, increased parasitic components and
power consumption and so on. The majority of the researchers have
their spotlight only on EMI mitigation without considering the other
constraints such as cost, effective operation of the equipment etc. In
this paper, we propose a technique for EMI mitigation in fluorescent
lamps by integrating Frequency Modulation and Evolutionary
Programming. By the Frequency Modulation technique, the
switching at a single central frequency is extended to a range of
frequencies, and so, the power is distributed throughout the range of
frequencies leading to EMI mitigation. But in order to meet the
operating frequency of the ballast and the operating power of the
fluorescent lamps, an optimal modulation index is necessary for
Frequency Modulation. The optimal modulation index is determined
using Evolutionary Programming. Thereby, the proposed technique
mitigates the EMI to a satisfactory level without disturbing the
operation of the fluorescent lamp.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.
Abstract: Named Entity Recognition (NER) aims to classify each word of a document into predefined target named entity classes and is now-a-days considered to be fundamental for many Natural Language Processing (NLP) tasks such as information retrieval, machine translation, information extraction, question answering systems and others. This paper reports about the development of a NER system for Bengali and Hindi using Support Vector Machine (SVM). Though this state of the art machine learning technique has been widely applied to NER in several well-studied languages, the use of this technique to Indian languages (ILs) is very new. The system makes use of the different contextual information of the words along with the variety of features that are helpful in predicting the four different named (NE) classes, such as Person name, Location name, Organization name and Miscellaneous name. We have used the annotated corpora of 122,467 tokens of Bengali and 502,974 tokens of Hindi tagged with the twelve different NE classes 1, defined as part of the IJCNLP-08 NER Shared Task for South and South East Asian Languages (SSEAL) 2. In addition, we have manually annotated 150K wordforms of the Bengali news corpus, developed from the web-archive of a leading Bengali newspaper. We have also developed an unsupervised algorithm in order to generate the lexical context patterns from a part of the unlabeled Bengali news corpus. Lexical patterns have been used as the features of SVM in order to improve the system performance. The NER system has been tested with the gold standard test sets of 35K, and 60K tokens for Bengali, and Hindi, respectively. Evaluation results have demonstrated the recall, precision, and f-score values of 88.61%, 80.12%, and 84.15%, respectively, for Bengali and 80.23%, 74.34%, and 77.17%, respectively, for Hindi. Results show the improvement in the f-score by 5.13% with the use of context patterns. Statistical analysis, ANOVA is also performed to compare the performance of the proposed NER system with that of the existing HMM based system for both the languages.
Abstract: A clustering based technique has been developed and implemented for Short Term Load Forecasting, in this article. Formulation has been done using Mean Absolute Percentage Error (MAPE) as an objective function. Data Matrix and cluster size are optimization variables. Model designed, uses two temperature variables. This is compared with six input Radial Basis Function Neural Network (RBFNN) and Fuzzy Inference Neural Network (FINN) for the data of the same system, for same time period. The fuzzy inference system has the network structure and the training procedure of a neural network which initially creates a rule base from existing historical load data. It is observed that the proposed clustering based model is giving better forecasting accuracy as compared to the other two methods. Test results also indicate that the RBFNN can forecast future loads with accuracy comparable to that of proposed method, where as the training time required in the case of FINN is much less.
Abstract: This paper addresses the problems encountered by conventional distance relays when protecting double-circuit transmission lines. The problems arise principally as a result of the mutual coupling between the two circuits under different fault conditions; this mutual coupling is highly nonlinear in nature. An adaptive protection scheme is proposed for such lines based on application of artificial neural network (ANN). ANN has the ability to classify the nonlinear relationship between measured signals by identifying different patterns of the associated signals. One of the key points of the present work is that only current signals measured at local end have been used to detect and classify the faults in the double circuit transmission line with double end infeed. The adaptive protection scheme is tested under a specific fault type, but varying fault location, fault resistance, fault inception angle and with remote end infeed. An improved performance is experienced once the neural network is trained adequately, which performs precisely when faced with different system parameters and conditions. The entire test results clearly show that the fault is detected and classified within a quarter cycle; thus the proposed adaptive protection technique is well suited for double circuit transmission line fault detection & classification. Results of performance studies show that the proposed neural network-based module can improve the performance of conventional fault selection algorithms.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetically and thermal stresses remain major failures
for insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: In the present study, position estimation of switched reluctance motor (SRM) has been achieved on the basis of the artificial neural networks (ANNs). The ANNs can estimate the rotor position without using an extra rotor position sensor by measuring the phase flux linkages and phase currents. Flux linkage-phase current-rotor position data set and supervised backpropagation learning algorithm are used in training of the ANN based position estimator. A 4-phase SRM have been used to verify the accuracy and feasibility of the proposed position estimator. Simulation results show that the proposed position estimator gives precise and accurate position estimations for both under the low and high level reference speeds of the SRM
Abstract: Voltage flicker is a disturbance in electrical power
systems. The reason for this disturbance is mainly the large nonlinear
loads such as electric arc furnaces. Synchronous static
compensator (STATCOM) is considered as a proper technique to
mitigate the voltage flicker. Application of more suitable and precise
power electronic converter leads to a more precise performance of the
compensator. In this paper a three-level 12-pulse voltage source
inverter (VSI) with a 12-terminal transformer connected to the ac
system is studied and the obtained results are compared with the
performance of a STATCOM using a simple two-level VSI and an
optimal and more precise performance of the proposed scheme is
achieved.
Abstract: This paper presents an idea to improve the efficiency
of security checks in airports through the active tracking and
monitoring of passengers and staff using OFDM modulation
technique and Finger print authentication. The details of the
passenger are multiplexed using OFDM .To authenticate the
passenger, the fingerprint along with important identification
information is collected. The details of the passenger can be
transmitted after necessary modulation, and received using various
transceivers placed within the premises of the airport, and checked at
the appropriate check points, thereby increasing the efficiency of
checking. OFDM has been employed for spectral efficiency.
Abstract: Phase locked loops for data links operating at 10 Gb/s
or faster are low phase noise devices designed to operate with a low
jitter reference clock. Characterization of their jitter transfer function
is difficult because the intrinsic noise of the device is comparable to
the random noise level in the reference clock signal. A linear model
is proposed to account for the intrinsic noise of a PLL. The intrinsic
noise data of a PLL for 10 Gb/s links is presented. The jitter transfer
function of a PLL in a test chip for 12.8 Gb/s data links was
determined in experiments using the 400 MHz reference clock as the
source of simultaneous excitations over a wide range of frequency.
The result shows that the PLL jitter transfer function can be
approximated by a second order linear model.
Abstract: Short circuit currents plays a vital role in influencing the design and operation of equipment and power system and could not be avoided despite careful planning and design, good maintenance and thorough operation of the system. This paper discusses the short circuit analysis conducted in KSO briefly comprising of its significances, methods and results. A result sample of the analysis based on a single transformer is detailed in this paper. Furthermore, the results of the analysis and its significances were also discussed and commented.
Abstract: There has been a growing interest in the field of
bio-mimetic robots that resemble the shape of an insect or an aquatic
animal, among many others. One bio-mimetic robot serves the
purpose of exploring pipelines, spotting any troubled areas or
malfunctions and reporting its data. Moreover, the robot is able to
prepare for and react to any abnormal routes in the pipeline. In order
to move effectively inside a pipeline, the robot-s movement will
resemble that of a lizard. When situated in massive pipelines with
complex routes, the robot places fixed sensors in several important
spots in order to complete its monitoring. This monitoring task is to
prevent a major system failure by preemptively recognizing any minor
or partial malfunctions. Areas uncovered by fixed sensors are usually
impossible to provide real-time observation and examination, and thus
are dependant on periodical offline monitoring. This paper provides
the Monitoring System that is able to monitor the entire area of
pipelines–with and without fixed sensors–by using the bio-mimetic
robot.
Abstract: ICA which is generally used for blind source separation
problem has been tested for feature extraction in Speech recognition
system to replace the phoneme based approach of MFCC. Applying
the Cepstral coefficients generated to ICA as preprocessing has
developed a new signal processing approach. This gives much better
results against MFCC and ICA separately, both for word and speaker
recognition. The mixing matrix A is different before and after MFCC
as expected. As Mel is a nonlinear scale. However, cepstrals
generated from Linear Predictive Coefficient being independent
prove to be the right candidate for ICA. Matlab is the tool used for
all comparisons. The database used is samples of ISOLET.
Abstract: In this paper we present two novel 1-bit full adder
cells in dynamic logic style. NP-CMOS (Zipper) and Multi-Output
structures are used to design the adder blocks. Characteristic of
dynamic logic leads to higher speeds than the other standard static
full adder cells. Using HSpice and 0.18┬Ám CMOS technology
exhibits a significant decrease in the cell delay which can result in a
considerable reduction in the power-delay product (PDP). The PDP
of Multi-Output design at 1.8v power supply is around 0.15 femto
joule that is 5% lower than conventional dynamic full adder cell and
at least 21% lower than other static full adders.
Abstract: Standard packaging and interconnection technologies
of power devices have difficulties meeting the increasing thermal
demands of new application fields of power electronics devices.
Main restrictions are the decreasing reliability of bond-wires and
solder layers with increasing junction temperature. In the last few
years intensive efforts have been invested in developing new
packaging and interconnection solutions which may open a path to
future application of power devices. In this paper, the main failure
mechanisms of power devices are described and principle of new
packaging and interconnection concepts and their power cycling
reliability are presented.
Abstract: The continued interest in the use of distributed generation in recent years is leading to the growth in number of distributed generators connected to distribution networks. Steady state voltage rise resulting from the connection of these generators can be a major obstacle to their connection at lower voltage levels. The present electric distribution network is designed to keep the customer voltage within tolerance limit. This may require a reduction in connectable generation capacity, under utilization of appropriate generation sites. Thus distribution network operators need a proper voltage regulation method to allow the significant integration of distributed generation systems to existing network. In this work a voltage rise problem in a typical distribution system has been studied. A method for voltage regulation of distribution system with multiple DG system by coordinated operation distributed generator, capacitor and OLTC has been developed. A sensitivity based analysis has been carried out to determine the priority for individual generators in multiple DG environment. The effectiveness of the developed method has been evaluated under various cases through simulation results.