Abstract: For electrocardiogram (ECG) biometrics system, it is a tedious process to pre-install user’s high-intensity heart rate (HR) templates in ECG biometric systems. Based on only resting enrollment templates, it is a challenge to identify human by using ECG with the high-intensity HR caused from exercises and stress. This research provides a heartbeat segment method with slope-oriented neural networks against the ECG morphology changes due to high intensity HRs. The method has overall system accuracy at 97.73% which includes six levels of HR intensities. A cumulative match characteristic curve is also used to compare with other traditional ECG biometric methods.
Abstract: In this paper, an efficient method for personal identification based on the pattern of human iris is proposed. It is composed of image acquisition, image preprocessing to make a flat iris then it is converted into eigeniris and decision is carried out using only reduction of iris in one dimension. By comparing the eigenirises it is determined whether two irises are similar. The results show that proposed method is quite effective.
Abstract: Estimation of stature is an important step in developing a biological profile for human identification. It may provide a valuable indicator for unknown individual in a population. The aim of this study was to analyses the relationship between stature and lower limb dimensions in the Malaysian population. The sample comprised 100 corpses, which included 69 males and 31 females between age ranges of 20 to 90 years old. The parameters measured were stature, thigh length, lower leg length, leg length, foot length, foot height and foot breadth. Results showed that mean values in males were significantly higher than those in females (P < 0.05). There were significant correlations between lower limb dimensions and stature. Cross-validation of the equation on 100 individuals showed close approximation between known stature and estimated stature. It was concluded that lower limb dimensions were useful for estimation of stature, which should be validated in future studies.
Abstract: Heart sound is an acoustic signal and many techniques
used nowadays for human recognition tasks borrow speech recognition
techniques. One popular choice for feature extraction of accoustic
signals is the Mel Frequency Cepstral Coefficients (MFCC) which
maps the signal onto a non-linear Mel-Scale that mimics the human
hearing. However the Mel-Scale is almost linear in the frequency
region of heart sounds and thus should produce similar results with
the standard cepstral coefficients (CC). In this paper, MFCC is
investigated to see if it produces superior results for PCG based
human identification system compared to CC. Results show that the
MFCC system is still superior to CC despite linear filter-banks in
the lower frequency range, giving up to 95% correct recognition rate
for MFCC and 90% for CC. Further experiments show that the high
recognition rate is due to the implementation of filter-banks and not
from Mel-Scaling.
Abstract: Single biometric modality recognition is not able to meet the high performance supplies in most cases with its application become more and more broadly. Multimodal biometrics identification represents an emerging trend recently. This paper investigates a novel algorithm based on fusion of both fingerprint and fingervein biometrics. For both biometric recognition, we employ the Monogenic Local Binary Pattern (MonoLBP). This operator integrate the orginal LBP (Local Binary Pattern ) with both other rotation invariant measures: local phase and local surface type. Experimental results confirm that a weighted sum based proposed fusion achieves excellent identification performances opposite unimodal biometric systems. The AUC of proposed approach based on combining the two modalities has very close to unity (0.93).
Abstract: Biometrics methods include recognition techniques
such as fingerprint, iris, hand geometry, voice, face, ears and gait. The gait recognition approach has some advantages, for example it
does not need the prior concern of the observed subject and it can
record many biometric features in order to make deeper analysis, but
most of the research proposals use high computational cost. This
paper shows a gait recognition system with feature subtraction on a
bundle rectangle drawn over the observed person. Statistical results
within a database of 500 videos are shown.
Abstract: Human identification at a distance has recently gained
growing interest from computer vision researchers. Gait recognition
aims essentially to address this problem by identifying people based
on the way they walk [1]. Gait recognition has 3 steps. The first step
is preprocessing, the second step is feature extraction and the third
one is classification. This paper focuses on the classification step that
is essential to increase the CCR (Correct Classification Rate).
Multilayer Perceptron (MLP) is used in this work. Neural Networks
imitate the human brain to perform intelligent tasks [3].They can
represent complicated relationships between input and output and
acquire knowledge about these relationships directly from the data
[2]. In this paper we apply MLP NN for 11 views in our database and
compare the CCR values for these views. Experiments are performed
with the NLPR databases, and the effectiveness of the proposed
method for gait recognition is demonstrated.
Abstract: This paper discusses the effectiveness of the EEG signal
for human identification using four or less of channels of two different
types of EEG recordings. Studies have shown that the EEG signal
has biometric potential because signal varies from person to person
and impossible to replicate and steal. Data were collected from 10
male subjects while resting with eyes open and eyes closed in 5
separate sessions conducted over a course of two weeks. Features
were extracted using the wavelet packet decomposition and analyzed
to obtain the feature vectors. Subsequently, the neural networks
algorithm was used to classify the feature vectors. Results show that,
whether or not the subjects- eyes were open are insignificant for a 4–
channel biometrics system with a classification rate of 81%. However,
for a 2–channel system, the P4 channel should not be included if data
is acquired with the subjects- eyes open. It was observed that for 2–
channel system using only the C3 and C4 channels, a classification
rate of 71% was achieved.